background image

 

 

EFP 2005 – loudspeaking doorphone 

Page 

5

Terminal block at the lower left is for cable to outdoor unit. 
Terminal block at the top left is marked "FREE". This is made as a help to the technician if 
there is a need for joining wires etc. No one of the connection points are connected to each 
other or to components on the PCB. 
 
Description of the connections: 
12V and GND is powersupply to the amplifier. Only use direct current (DC). 
La, Lb is sound between indoor unit and amplifier box. 
DB is DoorBell, one-pole switch in outdoor unit. Connects GND back to indoor unit. 
LS is LoudSpeaker, sound to loudspeaker in outdoor unit. Non-polarized. 
Mic+ and Mic- is sound from the outdoor units microphone. Polarized. 
 
 

Содержание EFP 2005

Страница 1: ...hanged revisionlist to new type 01 08 08 Bent Håvard Sollid New version of outdoor unit Ch 6 2 1 changed text Ch 6 2 3 6 2 4 changed wiring diagram 01 01 12 Bent Håvard Sollid Added wiring diagram for the new version of PicoCombi MK II Contents Documentation EFP 2005 1 Introduction 2 2 Getting started installation 2 3 User manual 2 3 1 Accessories 3 4 Maintenance 3 4 1 Cleaning 3 4 2 Outdoor use 3...

Страница 2: ...icolo and PicoCombi or an Erifox PABX Indoor unit is not included in the EFP 2005 shipment EFP 2005 made for Picolo PicoCombi can not be connected to an Erifox version or v v The Erifox version is clearly marked with Erifox Find a suitable place to mount the outdoor unit It is recommended to place it where it is shielded for wind and precipitation There is space for the users name on the outdoor u...

Страница 3: ...in and snow The reason for this is that water will be able to get inside the box and degrade the equipments function 5 Troubleshooting If your equipment does not behave as expected first of all try to solve the problem yourself using the following table Symptom Possible cause Recommended action Completely dead Light indicator not illuminated No power connected to the indoor unit the EFP 2005 is po...

Страница 4: ...PCB A red LED illuminates when power is connected Potentiometer GAIN Can be used to regulate speaker volume in outdoor unit Outdoor unit Front part with microphone loudspeaker and pushbutton Frontfoil glued on front part Picomeds logo product name and space made for the users name on it with a label waterproof pen etc Backside has 6 electrical connections Frame for wall mounting 6 1 Fixed mounting...

Страница 5: ... connection points are connected to each other or to components on the PCB Description of the connections 12V and GND is powersupply to the amplifier Only use direct current DC La Lb is sound between indoor unit and amplifier box DB is DoorBell one pole switch in outdoor unit Connects GND back to indoor unit LS is LoudSpeaker sound to loudspeaker in outdoor unit Non polarized Mic and Mic is sound ...

Страница 6: ...EFP 2005 loudspeaking doorphone Page 6 6 2 3 Wiring diagram for Picolo PicoCombi version I ...

Страница 7: ...EFP 2005 loudspeaking doorphone Page 7 6 2 4 Wiring diagram for Picolo PicoCombi version II OBS this is for PicoCombi MK II not same diagram as for MKI ...

Страница 8: ...EFP 2005 loudspeaking doorphone Page 8 6 2 5 Wiring diagram for Erifox PABX ...

Страница 9: ... and that it is possible to have 2 way communication between out and in indoor units Adjust potentiometer for outdoor loudspeaker volume GAIN clockwise until end stop thereafter counter clockwise 90º Store 6 4 Technical data Type Picomed EFP 2005 doorphone Operating Pushbutton on outdoor unit The conversation is activated from indoor unit not included Voice direction is electronically controlled P...

Страница 10: ......

Отзывы: