5.

 

Signal leads 

a.  Output Lead.    The BNC output connector and an auxiliary grounding terminal 

are connected to the oscilloscope. 

b.  Input Leads.    The input leads of the differential probe connect to sprung 

hooks that come with the probe. 

c.  Sprung Hooks.    The sprung hooks are connected safely to test points in the 

circuits under test. 

6.

 

Power leads 

Two types of power leads are available for use with this instrument: 
1.

 

Lemo

®

 Lead:    For oscilloscopes with Lemo

®

 power connectors. 

2.

 

Probus

®

 Lead:    For oscilloscopes with Probus

®

 power connectors. 

 

Oscilloscope front 
panel 

Содержание TA041

Страница 1: ...bols Terms appearing in this manual WARNING Warning statements identify conditions or practices that could result in injury or death CAUTION Caution statements identify conditions or practices that co...

Страница 2: ...ou must verify that the probe is securely grounded before connecting the probe input leads Some types of measuring instrument such as a USB oscilloscope connected to a laptop are unlikely to be ground...

Страница 3: ...ed controls switch mode power supplies and many other applications 4 Installation Simply plug in the BNC output connector to the vertical input of a general purpose oscilloscope or other measurement i...

Страница 4: ...s The input leads of the differential probe connect to sprung hooks that come with the probe c Sprung Hooks The sprung hooks are connected safely to test points in the circuits under test 6 Power lead...

Страница 5: ...6 dB 50 Hz 66 dB 20 kHz Ambient Operating Temperature 10 to 40 C Ambient Storage Temperature 30 to 70 C Ambient Operating Humidity 25 to 85 RH Ambient Storage Humidity 25 to 85 RH Power Requirements S...

Страница 6: ...logy 6 Copyright Pico Technology 2008 2012 DO141 4 8 Derating curve The derating curve for absolute maximum input voltage is as follows 1000 1000 700 150 100 1000 10000 1 E 06 1 E 07 1 E 08 Voltage V...