pico Technology PicoScope 6000A Series Скачать руководство пользователя страница 7

PicoScope 6000A/B Series User's Guide

3

Copyright © 2012 Pico Technology Ltd. All rights reserved.

ps6000ab.en

2.4

FCC notice

This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to 

Part 15 of the FCC Rules

. These limits are designed to

provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his or her own
expense.

For safety and maintenance information see the 

safety warning

.

2.5

CE notice

The product meets the intent of the 

EMC directive 89/336/EEC

 and has been tested

to 

EN61326-1:2006 Class A Emissions and Immunity

 standard. 

The product also meets the intent of the 

Low Voltage Directive 

and has been

designed to meet the 

BS EN 61010-1:2001 IEC 61010-1:2001 Safety

requirements for electrical equipment for measurement, control, and
laboratory use 

standard.

2.6

Software licence conditions

The material contained in this software release is licensed, not sold. Pico Technology
Limited ('Pico') grants a license to the person who installs this software, subject to
the conditions listed below.

Access. 

The licensee agrees to allow access to this software only to persons who have

been informed of and agree to abide by these conditions.

Usage. 

The software in this release is for use only with Pico Technology products or

with data collected using Pico products.

Copyright. 

Pico claims the copyright of and reserves the rights to all material

(software, documents etc.) contained in this release.

Liability. 

Pico and its agents shall not be liable for any loss, damage or injury,

howsoever caused, related to the use of Pico equipment or software, unless excluded
by statute.

Fitness for purpose. 

No two applications are the same, so Pico cannot guarantee

that its equipment or software is suitable for a given application. It is therefore the
user's responsibility to ensure that the product is suitable for the user's application.

Mission-critical applications. 

Because the software runs on a computer that may be

running other software products, and may be subject to interference from these other
products, this license specifically excludes usage in 'mission-critical' applications, for
example life-support systems.

Viruses. 

This software was continuously monitored for viruses during production.

However, the user is responsible for virus checking the software once it is installed.

Support. 

No software is ever error-free, but if you are dissatisfied with the

performance of this software, please contact our technical support staff.

Содержание PicoScope 6000A Series

Страница 1: ...Copyright 2012 Pico Technology Ltd All rights reserved PicoScope 6000A B Series User s Guide ps6000ab en 1 PC Oscilloscopes ...

Страница 2: ......

Страница 3: ...Using this guide 2 2 Safety symbols 2 3 Safety warnings 3 4 FCC notice 3 5 CE notice 3 6 Software licence conditions 4 7 Returns and upgrades 4 8 Trademarks 4 9 Warranty 4 10 Company details 5 3 Product information 5 1 Package contents 5 2 Selection table 5 3 Minimum PC requirements 6 4 Installation instructions 7 5 Connections 8 4 Glossary 9 Index ...

Страница 4: ......

Страница 5: ...ou and plug it in to any Windows PC Performance Up to 5 GS s sampling 500 MHz bandwidth and 1 GS buffer Flexibility Use it as an oscilloscope spectrum analyzer or high speed data acquisition interface Programmability The PicoScope 6000 Series SDK lets you write your own programs in your chosen programming language to control all the features of the scope Long term support Software upgrades are ava...

Страница 6: ...ore using your oscilloscope for the first time Safety protection built in to equipment may cease to function if the equipment is used incorrectly This could cause damage to your computer or lead to injury to yourself and others DO NOT exceed the overload protection range The product is designed to measure signals within the range 20 V The inputs can withstand 100 V to ground when set to 1 MΩ imped...

Страница 7: ... Technology Limited Pico grants a license to the person who installs this software subject to the conditions listed below Access The licensee agrees to allow access to this software only to persons who have been informed of and agree to abide by these conditions Usage The software in this release is for use only with Pico Technology products or with data collected using Pico products Copyright Pic...

Страница 8: ...gy are registered in the U S Patent and Trademark Office 2 9 Warranty Pico Technology warrants upon delivery and for a period of 5 years from the date of delivery that the Goods will be free from defects in material and workmanship Pico Technology shall not be liable for a breach of the warranty if the defect has been caused by fair wear and tear wilful damage negligence abnormal working condition...

Страница 9: ...div with ETS Buffer memory 128 MS 256 MS 512 MS 1 GS Signal generator Function AWG Function AWG Function AWG For full specifications see the PicoScope 6000 Series Data Sheet available from picotech com 3 3 Minimum PC requirements To ensure that your PicoScope 6000 Series oscilloscope operates correctly you must have a computer with at least the minimum system requirements to run one of the support...

Страница 10: ...any signal connected to the scope inputs If a probe is connected to your oscilloscope you should see a small noise signal in the oscilloscope window when you touch the probe tip with your finger Moving the PicoScope PC Oscilloscope to another USB port Windows XP SP2 When you first installed the oscilloscope by plugging it into a USB port Windows associated the Pico driver with that port If you lat...

Страница 11: ... probes supplied with it Connector diagrams Front panel PicoScope 6000 Series A Input channel A B Input channel B C Input channel C D Input channel D E Probe calibration output F LED shows when the oscilloscope is sampling data Rear panel PicoScope 6000 Series G DC power socket for use with the AC adaptor supplied with the unit H USB 2 0 port connects to your PC using the Hi Speed USB cable suppli...

Страница 12: ...e high frequency details in a fast signal MS Megasamples approx 1 million samples PC Oscilloscope A virtual instrument formed by connecting a PicoScope oscilloscope to a computer running the PicoScope software PicoScope software A software product that accompanies all PicoScope oscilloscopes It turns your PC into an oscilloscope spectrum analyzer and multimeter Timebase The timebase controls the t...

Страница 13: ...ternal trigger 7 F FCC notice 3 Function generator 5 G Grounding 2 I Installation 6 L LED 7 Low Voltage Directive LVD 3 M Mains voltages 2 Maximum sampling rate 5 O Oscilloscope probe 7 P PC requirements 5 Pico Technical Support 4 PicoScope 6000 Series 1 PicoScope software 6 Power socket 7 Probes 5 R Returns 4 S Safety symbols 2 warning 2 Scope probe 7 Signal generator 5 output 7 Software license ...

Страница 14: ......

Страница 15: ...PicoScope 6000A B Series User s Guide 11 Copyright 2012 Pico Technology Ltd All rights reserved ps6000ab en ...

Страница 16: ...mes House Colmworth Business Park ST NEOTS Cambridgeshire PE19 8YP United Kingdom Tel 44 0 1480 396 395 Fax 44 0 1480 396 296 www picotech com Copyright 2012 Pico Technology Ltd All rights reserved ps6000ab en 1 21 3 12 ...

Отзывы: