Pico Macom TA-36 Скачать руководство пользователя страница 2

PICO MACOM, INC.

 

12500 Foothill Blvd. • Lakeview Terrace, CA 91342 • (818) 897-0028  (800) 421-6511 • FAX (818) 834-7197

Safeguards

Important Information

R e a d   T h i s   F i r s t

R e a d   T h i s   F i r s t

1

WARNING:

    

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS

APPLIANCE TO RAIN OR MOISTURE.  DO NOT OPEN THE CABINET.  REFER SERVICING TO QUALIFIED
PERSONNEL ONLY.

CAUTION: 

   

TO PREVENT ELECTRIC SHOCK DO NOT USE THIS (POLARIZED) PLUG WITH AN

EXTENSION CORD RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED
TO BLADE EXPOSURE.

ATTENCION:

POUR PREVENIR LES CHOCS ELECTRIQUES, NE PAS UTILISER CETTE FICHE

POLARISEE AVEC UN PROLONGATEUR, UNE PRISE DE  COURANT OU UNE AUTRE SORTIE DE
COURANT, SAUF SI LES LAMES PEUVENT ETRE INSEREES A FOND SANS EN LAISSER AUCUNE
PARTIE A DECOUVERT.

The lightning flash with arrowhead symbol,
within an equilateral triangle, is intended to alert
the user to the presence of uninsulated “dan-
gerous voltage” within the product’s enclosure
that may be of sufficient magnitude to constitute
a risk of electric shock to persons.
The exclamation point within an equilateral tri-
angle is intended to alert the user to the pres-

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING

FOR  INDOOR  USE ONLY. TO PREVENT  FIRE OR SHOCK 

HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.

Product Inspection

Inspect the equipment for shipping damage. Should any damage be discovered,

immediately file a claim with the carrier.

Important Safety  Instructions

To insure proper installation and operation, take a moment to read this guide

before proceeding with the installation.  If you have any questions or comments about
the TA-12 amplifier, please contact the 

PICO MACOM 

 Service Center at the phone

numbers on the bottom of the page.

1.  Read Instructions All safety and operating instructions should be read before the appliance is operated.

2.  Retain Instructions The safety and operating instructions should be retained for future reference.

3.  Heed Warnings - All warnings on the appliance should be  adhered to.

4.  Follow Instructions - All operating and use instructions should  be followed.

5.  Cleaning - Unplug this appliance from the wall outlet before  cleaning.  Use a damp cloth for cleaning.  Do
not use liquid cleaners or aerosol cleansers.

6.  Do Not Use Attachments - Not recommended by the manufacturer or they may cause hazards.

ence of important operating and maintenance (ser-
vicing) instructions in the literature accompanying
the appliance.

Содержание TA-36

Страница 1: ...M INC 12500 Foothill Blvd Lakeview Terrace CA 91342 818 897 0028 800 421 6511 FAX 818 834 7197 Installation And Operation Manual UHF VHF FM Distribution Amplifier ODoc No OM2190 3 Rev A ECO 1750 P N 911069 TA 36 ...

Страница 2: ...e user to the pres CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING FOR INDOOR USE ONLY TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE Product Inspection Inspect the equipment for shipping damage Should any damage be discovered immediately file a claim with the carrier Important Safety Instructions To insure proper installation and operation take a moment to rea...

Страница 3: ...the type of power source indicated on the marking label If you are not sure of the type of power supplied to your home consult your appliance dealer or local power company 12 Power cord Protection Power supply cords should be routed so they are not likely to be walked on or pinched by items placed upon or against them Pay particular attention to cords and plugs convenience receptacles and the poin...

Страница 4: ...n to restore the product to its normal operation e If the product has been dropped or the cabinet has been damaged 19 Replacement Parts When replacement parts are required be sure the service technician has used replacement parts specified by the manufacturer or have the same characteristics as the original parts Unauthorized substitutes may result in fire electric shock or other hazards 20 Safety...

Страница 5: ...e Figure VHF 6 dB UHF 7 dB Channels Max Input Max Output 7 channels VHF 20 dBmV 52 dBmV 4 channels UHF 20 dBmV 56 dBmV 12 channels VHF 11 dBmV 43 dBmV 7 UHF 11 dBmV 45 dBmV Power Requirements 117Vac 60Hz 9 5W Features Two switchable FM traps Separate gain controls Low noise 20 dB monitor output Excellent for medium size MATV applications Low noise 50 dB output capability Specifications Features IN...

Страница 6: ...00 dB Start 54 000 MHz Stop 806 000 MHz 1 Mkr MHz dB TYP 1 54 00 31 09 2 88 00 32 27 3 216 00 31 34 4 470 00 36 32 5 806 00 36 11 40 10 1 2 3 5 4 INPUT OUTPUT IN MODEL TA 36 AMPLIFIER UHF VHF FM TEST POINT 20 DB 60Hz 9 5W FUSE FUSE IN FM TRAP OUT GAIN MAX LO HI VHF CAUTION DO NOT EXCEED RECOMMENDED INPUT POWER RATING SEE PAGE 4 TO DISTRIBUTION SYSTEM SPLITTERS AND TAPS VHF IUHF ANTENNA GROUND BLOC...

Страница 7: ...B Ref 20 00 dB Start 80 000 MHz Stop 120 000 MHz 1 Mkr MHz dB TYP 1 88 00 30 38 2 95 00 2 06 3 108 00 6 54 4 120 00 30 15 2 Mkr MHz dB TYP 40 10 1 2 4 3 40 30 20 Ch1 10 20 30 1 Transmission Log Mag 10 0 dB Ref 20 00 dB Start 76 000 MHz Stop 116 000 MHz 1 Mkr MHz dB TYP 1 80 00 30 48 2 88 00 7 27 3 96 00 5 84 4 108 00 31 76 5 120 00 31 11 40 10 1 2 3 5 4 FM Trap 88 to 96 MHz FM Trap 95 to 108 MHz ...

Страница 8: ...imitations on how long an implied warranty lasts or do not allow exclusions or limitation of incidental or consequential damages so the above limitation and exclusion may or may not apply to you This warranty gives you specific legal rights and you also have rights which vary from state to state U S A the limitations or exclusions set out below During the warranty period Pico Macom Inc or an autho...

Страница 9: ...5 x 4 t L28 0 4 x 3 x 3 t Q4 2SC2369 R31 2 2 R30 3 9 0 R32 1 0 C44 1000p C45 10p R29 3 k R28 3 6k C41 6p L26 0 4 x 2 5 x 3 t Q3 2SC2369 R25 1 k R23 3 6k C38 1000p R26 4 7 0 R24 3 k C39 1000p C48 1000p T 3 2 t C37 1000p R47 4 7 0 VR20 1 k C61 2p C60 2p C36 4 7p R22 1 1 0 C35 3p C34 4p L24 0 6 x 3 2 x 4 t L25 0 6 x 3 x 3 t L23 0 6 x 3 x 3 t C33 3p R19 4 7M FF1 PP1 XFMR1 F1 R44 1 5M D2 IN4002 D3 IN40...

Страница 10: ...PICO MACOM INC 12500 Foothill Blvd Lakeview Terrace CA 91342 818 897 0028 800 421 6511 FAX 818 834 7197 ...

Страница 11: ...PICO MACOM INC 12500 Foothill Blvd Lakeview Terrace CA 91342 818 897 0028 800 421 6511 FAX 818 834 7197 ...

Страница 12: ...PICO MACOM INC 12500 Foothill Blvd Lakeview Terrace CA 91342 818 897 0028 800 421 6511 FAX 818 834 7197 PICO MACOM INC U S A Spec Tru ...

Отзывы: