background image

PICO MACOM, INC.

 

 

12500 Foothill Blvd.  •  Lakeview Terrace, CA 91342  •  (818) 897-0028  • (800) 421-6511 • FAX (818) 834-7197

S A F E G U A R D S

Product Inspection

Inspect  the  equipment  for  shipping  damage.

Should any damage be discovered, immediately file
a claim with the carrier.

Important
Safety Instructions

To  insure  proper  installation  and  operation,

take a moment to read this guide before proceeding
with the installation.  If you have any questions or
comments about the 

PIDA 

amplifier, please contact

your dealer or have him contact the 

PICO MACOM

Service Center  at the phone numbers on the bottom
of the page.

WARNING:

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE
THIS APPLIANCE TO RAIN OR MOISTURE.  DO NOT OPEN THE CABINET,
REFER SERVICING TO QUALIFIED PERSONNEL ONLY.

CAUTION:

TO PREVENT ELECTRIC SHOCK DO NOT USE THIS (POLARIZED) PLUG
WITH AN EXTENSION CORD RECEPTACLE OR OTHER OUTLET  UNLESS
THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE.

ATTENCION 

:

 POUR PREVENIR LES CHOCS ELECTRIQUES, NE PAS UTILISER CETTE

FICHE POLARISEE AVEC UN PROLONGATEUR, UNE PRISE DE  COURANT
OU UNE AUTRE SORTIE DE COURANT, SAUF SI LES LAMES PEUVENT
ETRE INSEREES A FOND SANS ENLAISSER AUCUNE PARTIE A
DECOUVERT.

1.  Read Instructions - All  safety and operating instructions
should be read before the appliance is operated.

2.  Retain Instructions - The safety and operating instructions
should be retained for future reference.

3.  Heed Warnings - All warnings on the appliance should be
adhered to.

4.  Follow Instructions - All operating and user instructions
should  be followed.

5.  Cleaning - Unplug this appliance from the wall outlet before
cleaning.  Use a damp cloth for cleaning.  Do not use liquid
cleaners or aerosol cleansers.

6.  Do Not Use Attachments - not recommended by the
manufacturer or they may cause hazards.

Important Information

7.  Water and Moisture - Do not use this product near water -
for example, near a bathtub, washbowl, kitchen sink, laundry
tub, in a wet basement, or near a swimming pool - and the like.

8.  Accessories - Do not place this product on an unstable cart,
stand, tripod, bracket, or table.  The product may fall, causing
serious injury to a child or adult, and serious damage to the
appliance.

9.  Ventilation - This video product should never be placed near
or over a radiator or heat register.  This video product should not
be placed in a built-in installation such as a bookcase or rack
unless proper ventilation is provided or the manufacturer’s
instructions have been adhered to.  Any slots or opening in the
cabinet are provided for ventilation.  To ensure reliable opera-
tion of the video product and to protect it from overheating, these
openings must not be blocked or covered.  The openings should
never be blocked by placing the product on a bed, sofa, rug, or
other similar surface.

1

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION:  TO REDUCE THE RISK OF ELECTRIC SHOCK,

                         

 DO NOT REMOVE COVER (OR BACK)

                       

 

NO USER-SERVICEABLE PARTS INSIDE

  

 

REFER SEVICING TO QUALIFIED SERVICE PERSONNEL

The lightning flash with arrowhead symbol, within an equilateral

triangle, is intended to alert the user to the presence of uninsulated

"dangerous voltage" within the product's enclosure that may be of

sufficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to

alert the user to the presence of important operating and mainte-

nance (servicing) instructions in the literature accompanying the

appliance.

Содержание PIDA-1000

Страница 1: ...60Hz O P 24V 1250mA AC ADAPTOR AHEAD HON KWANG PLUG IN CLASS 2 TRANSFORMER MODEL NO D12 10 03 INPUT 120V 60Hz 25W OUTPUT 26VAC 1 2A LISTED 69N0 E97199 UL 30dB TEST TWO WAY BROADBAND DISTRIBUTION AMPLIFIER GAIN M A X RETURN PATH SLOPE F L A T FOWARD PATH GAIN M A X ATTENTION GAIN SLOPE FACTORY SET TO MINIMUM M O D E L PIDA 550 PIDA 750 PIDA 1000 HPF LPF HPF LPF FA FA EQ F O W A R D P A T H R E T U ...

Страница 2: ...aning Use a damp cloth for cleaning Do not use liquid cleaners or aerosol cleansers 6 Do Not Use Attachments not recommended by the manufacturer or they may cause hazards Important Information 7 Water and Moisture Do not use this product near water for example near a bathtub washbowl kitchen sink laundry tub in a wet basement or near a swimming pool and the like 8 Accessories Do not place this pro...

Страница 3: ...struction Adjust only those controls that are covered by the operating instructions An improper adjustment may result in damage and will often require extensive work by a qualified technician to restore the product to its normal operation e If the product has been dropped or the cabinet has been damaged f When the product exhibits a distinct change in performance this indicates a need for service ...

Страница 4: ...made of aluminum to assure reliable heat sinking and corrosion resistance Specifications Foward Path Return Path Frequency Range PIDA 1000 50 1000MHz 5 36MHz PIDA 750 50 750MHz 5 36MHz PIDA 550 50 550MHz 5 36MHz Channel Loading 110 3 Flatness 0 75dB 0 5 ref to 1dB tilt Gain 30dB 20dB Noise Figure a 8 5dB 6dB Output Level 40dBmV 42dBmV Test Port Level 30 2dB Gain Control Range 10dB 18dB Slope Contr...

Страница 5: ...0 W5 W8 JUMPERS W5 AND W6 INSERTED FOR ACTIVE RETURN PATH REMOVE JUMPERS W6 AND W5 AND INSERT JUMPER BETWEEN THESE TWO POINTS FOR PASSIVE RETURN PATH PLUG IN LOCATION FOR EQUALIZER FORWARD PATH PLUG IN LOCATION FOR ATTENUATOR FORWARD PATH PLUG IN LOCATION FOR ATTENUATOR RETURN PATH SLOPE CONTROL FOWARD PATH GAIN CONTROL FOWARD PATH GAIN CONTROL RETURN PATH NOTE PLUG IN EQUALIZERS AND ATTENUATORS A...

Страница 6: ...O P1 AND P2 ANDJ2 TO P3 AND P4 3 PLUG IN EQUALIZERS AND ATTENUATORS ARE OPTIONAL IF PLUG INS ARE TO BE USED REMOVE JUMPER WIRE AT APPROPRIATE LOCATION AND INSERT PLUG IN HYBRID AMP 1 GAIN CONTROL CIRCUIT FULL SLOPE CONTROL CIRCUIT FLAT HYBRID AMP 2 GAIN CONTROL CIRCUIT FULL ATT RF OUTPUT RETURN PATH INPUT P1 P2 P3 P4 PASSIVE RETURN J1 J2 RF INPUT RETURN PATH OUTPUT TEST PORT 30dB W2 W3 W8 J3 49 MH...

Страница 7: ...X 818 834 7197 Power Adaptor Hook Up 6 I N S T A L L A T I O N Model MW57 02401250A I P AC120V 60Hz O P 24V 1250mA AC ADAPTOR AHEAD HON KWANG PLUG IN CLASS 2 TRANSFORMER MODEL NO D12 10 03 INPUT 120V 60Hz 25W OUTPUT 26VDC 1 0A LISTED 69N0 E97199 UL POWER STRIP TERMINAL FOR 26VAC 1A ADAPTOR ...

Страница 8: ...e inputs Normally the odd channels are combined on one row while even channels are combined on the other row of directional couplers The combiner loss is 16 dB per channel Another method of combining signals uses three hybrid splitters per headend rack The odd channels are combined in one splitter the even channels in another splitter and the two splitters are combined to a single output with a th...

Страница 9: ...arranty service contact the salesperson where the prod uctwasobtainedorcontactPicoMacom Incattheaddresslistedatbottomofpage You will be issued a Return Authoriza tion RA number which will be used to track your product Be prepared to provide 1 The model number and channel number of the product 2 The date of purchase 3 A specific identification of the problem Deliver the products to Pico Macom Inc o...

Страница 10: ...PICO MACOM INC 12500 Foothill Blvd Lakeview Terrace CA 91342 818 897 0028 800 421 6511 FAX 818 834 7197 N O T E S ...

Страница 11: ...PICO MACOM INC 12500 Foothill Blvd Lakeview Terrace CA 91342 818 897 0028 800 421 6511 FAX 818 834 7197 N O T E S ...

Страница 12: ...PICO MACOM INC 12500 Foothill Blvd Lakeview Terrace CA 91342 818 897 0028 800 421 6511 FAX 818 834 7197 ...

Отзывы: