background image

Installation and 

Operation Manual

MCM55

300MHz VHF High-Gain Push-Pull Amplifier

Operation 

Manual

Rev. 06/03

Ph: 800-421-6511

www.picomacom.com

MCM55 Manual.qxd  12/23/03  11:51 AM  Page 1

Содержание MCM-55

Страница 1: ...Installation and Operation Manual MCM55 300MHz VHF High Gain Push Pull Amplifier Operation Manual Rev 06 03 Ph 800 421 6511 www picomacom com MCM55 Manual qxd 12 23 03 11 51 AM Page 1 ...

Страница 2: ...ub washbowl kitchen sink laundry tub in a wet basement or near a swimming pool and the like 8 Accessories Do not place this product on an unstable cart stand tripod bracket or table The product may fall causing serious injury to a child or adult and serious damage to the appliance 9 Ventilation This video product should never be placed near or over a radiator or heat register This video product sh...

Страница 3: ...in or water d If the product does not operate normally by following the oper ating instruction Adjust only those controls that are covered by the operating instructions An improper adjustment may result in damage and will often require extensive work by a qualified tech nician to restore the product to its normal operation e If the product has been dropped or the cabinet has been damaged f When th...

Страница 4: ...k anodized extruded aluminum heat sink maximizes heat dissipation for improved reliability and corrosion resistance External UL approved power adapter supplied for ease of installation and to reduce heat build up within the unit The Pico Macom MCM55 is a high quality hybrid push pull wall mounted distribution amplifier producing signals with extremely low noise and harmonic distortion These amplif...

Страница 5: ... dBmV Frequency Range 300 MHz Gain Adjust Range 12 dB Slope Adjust Range 8 dB Flatness 5 dB from 54 300 MHz Noise Figure 6 5 dB Second Order Beats 70 dB Composite Triple Beat 61 dB Return Loss In 11 dB Return Loss Out 14 dB Test Points 30 dB Power Requirements 27 VAC 600 mA power adapter Operating Temperature 10 to 50 C Dimensions 8 L x 41 2 D x 2 H Weight 2 8 lbs Specifications Ordering Informati...

Страница 6: ... bandwidth 3 IN The input RF signal is connected to this port 4 OUT The amplified RF signal is available at this port 5 20 dB Input Test Monitor Input test point is provided to monitor input level to the amplifier 6 20 dB Output Test Monitor Output test point is provided for amplifier set up and monitoring 7 Power cable The power cable connects to a 120Vac 60Hz wall adaptor 1 2 3 4 6 5 7 MCM55 Man...

Страница 7: ...INPUT connector of the MCM55 2 Connect an F type jumper cable from the OUTPUT connector of the MCM55 to the distribution system 3 Plug the power cable into a polarized electrical outlet 4 Connect a RF signal level meter to the MCM55 OUTPUT test point connection and adjust the output level to match the distribution level requirements MCM55 Manual qxd 12 23 03 11 52 AM Page 7 ...

Страница 8: ...uthorization RMA number for the failed equipment and ask for a loaner unit We will issue an invoice for the List Price of the loaner unit plus shipping costs When you receive the loaner unit pack the failed unit in the loaner unit s box and ship it freight prepaid to Pico Macom for repair When you receive the repaired unit a new RMA number will be provided in the box Carefully pack the loaner unit...

Отзывы: