background image

M860

6

Rev. 06/03

Ph: 800-421-6511

www.picomacom.com

Operation and Controls

POWER

AURAL LEVEL

AUDIO MODULATION

VIDEO MODULATION

OUTPUT

LEVEL

TEST POINT

806MHz Channelized-Agile CATV A/V Modulator

M860

IRC

HRC

STD

12.5K

25K

LOCK

CH

CH

MODE

OFFSET

LOCK

STORE

-30 dB

1.

Power on LED: 

Indicates power is on when lit.

2.

Channel Display: 

Indicates current channel selection.

3.

Channel Indicator: 

LED’s indicate 12.5K, 25K offsets or LOCK channel status.

4.

Channel: 

Use this button to select higher channel.

5.

Channel: 

Use this button to select lower channel.

6.

Mode:

The RF level is set with this control.

7.

Offset:

Used to tune modulator to HRC or IRC offsets.

8.

Lock:

Use to block selected channels from being changed.

9.

Store: 

Push this button to store channel selection in non-volatile memory.

10. Aural Level: 

Used to set video/audio ratio.

11. Audio Modulation Indicator: 

Indicates audio over-modulation when lit.

12. Audio Modulation adjustment: 

Used to set audio modulation level. (volume).

13. Video Modulation adjustment:

Used to set video modulation adjust.

14. Video Modulation Indicator:

Indicates video over-modulation when lit.

15. Output Level:

Used to set RF output level.

16. -30 dB Output  test monitor:

Connect this port to monitor modulator RF output level.

Front Panel Control

RF OUT

EXT. 4.5 MHz IN

IF OUT

IF IN

VIDEO IN

AUDIO IN

117VAC

60Hz 38W

600W MAX 

125VAC 0.5A

CAUTION: FOR CONTINUED PROTECTION AGAINST FIRE
HAZARD, USE ONLY WITH SAME TYPE 0.5A  125V FUSE

L   GND    R

FUSE

1.

RF Out: 

Output port to connect unit to distribution system.

2.

Video Input: 

Accepts any  baseband video output source such as a satellite 
receiver, VCR, security camera or cable converter.

3.

Audio Input: 

Accepts any baseband audio output source such as a satellite 
receiver, VCR, security camera or cable converter.

4.

External 4.5MHz (BTSC) Input:

Stereo input from BTSC encoder.

5.

I.F. Output: 

To I.F. input or to scrambling device.

6.

I.F. Input:

Input from scrambling device or I.F. output.

7.

Fuse holder:

0.5 Amp slow-blow fuse.

8.

Convenience Outlet:

Provides 120 Vac, 60Hz at 600 watts max.

9.

Power cable:

The three-prong type power plug connects to a 120 VAC, 60 Hz 
electrical output.

Back Panel Control

1

2

1

2

3

4

5

6

7

8

9

3

4

6

8

5

7

9

11

10

12

13

14

15

16

Содержание M860

Страница 1: ...Installation and Operation Manual M860 806MHz Channelized Agile CATV A V Modulator Operation Manual Rev 06 03 Ph 800 421 6511 www picomacom com ...

Страница 2: ...bathtub washbowl kitchen sink laundry tub in a wet basement or near a swimming pool and the like 8 Accessories Do not place this product on an unstable cart stand tripod bracket or table The product may fall causing serious injury to a child or adult and serious damage to the appliance 9 Ventilation This video product should never be placed near or over a radiator or heat register This video produ...

Страница 3: ...as been exposed to rain or water d If the product does not operate normally by following the oper ating instruction Adjust only those controls that are covered by the operating instructions An improper adjustment may result in damage and will often require extensive work by a qualified tech nician to restore the product to its normal operation e If the product has been dropped or the cabinet has b...

Страница 4: ...cent channel interference and assures accurate and spurious free output Superior out of band carrier to noise performance is achieved through band pass filtering at the output amplifier The modulator is shipped with all internal adjustments preset FCC Docket 21006 offsets are standard Pico Macom backs up this product with its industry leading 5 year limited warranty 125 Channel Range 54 806 MHz CA...

Страница 5: ...onautical band Spurious Output 60 dB below video carrier with A V ratio 15 dB C N In Band 60dB C N Out of Band 65dB Fv 6 MHz Upper Adj Reject 60dBc Fv 1 5 MHz Lower Adj Reject 60dBc I F Frequency Video 45 75 MHz Audio 41 25 MHz Input Level 1 0 V p p min for 87 5 mod Input Type Clamped video neg sync Frequency Response 0 8 dB 30 Hz to 4 2 MHz Differential Gain 5 10 to 90 APL Differential Phase 5 10...

Страница 6: ...ent Used to set video modulation adjust 14 Video Modulation Indicator Indicates video over modulation when lit 15 Output Level Used to set RF output level 16 30 dB Output test monitor Connect this port to monitor modulator RF output level Front Panel Control RF OUT EXT 4 5MHzIN IF OUT IF IN VIDEO IN AUDIO IN 117VAC 60Hz 38W 600W MAX 125VAC 0 5A CAUTION FOR CONTINUED PROTECTION AGAINST FIRE HAZARD ...

Страница 7: ...10W AUDIO IN 600W MAX L R CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN _ _ _ _ VIDEO OUT COMPOSITE OUT 70 MHz IN OUT AUDIO OUTPUT LEVEL VIDEO LEVEL RF IN 950 1450 MHz 18V 250mA LNB POWER OUT ON OFF 117V 35A 60Hz DATA CLOCK LANGUAGE GND _ MONO LEFT RIGHT AUDIO OUTPUT FUSE AC25OV 1 2A H V L R MONO INV NOR STEREO AUDIO CONNECTION Center Conductor to Left Positive Shield to Left Negative Center Conducto...

Страница 8: ... return merchandise authorization RMA number for the failed equipment and ask for a loaner unit We will issue an invoice for the List Price of the loaner unit plus shipping costs When you receive the loaner unit pack the failed unit in the loaner unit s box and ship it freight prepaid to Pico Macom for repair When you receive the repaired unit a new RMA number will be provided in the box Carefully...

Отзывы: