background image

CA-30RK550

2

Rev. 08/03

Ph: 800-421-6511

www.picomacom.com

The lightning flash with arrowhead symbol, within an 
equilateral triangle, is intended to alert the user to the 
presence of un-insulated “dangerous voltage” within the 
product’s enclosure that may be of sufficient magnitude 
to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is 
intended to alert the user to the presence of important 
operating and maintenance (servicing) instructions in 
the literature accompanying the appliance.

Product Inspection

Inspect the equipment for shipping damage. Should any damage be discovered, immediately file a claim with the carrier.

Important Safety Instructions

To insure proper installation and operation, take a moment to read this guide before proceeding with the installation. If you have any questions 
or comments about the 

CA-30RK550

 550MHz Push-Pull Headend Amplifier, please contact your dealer or have him contact the 

PICO MACOM

 

Service Center at these phone numbers: 800-421-6511, 818-493-4300.

1

Read Instructions:

 All safety and operating instructions should 

be read before the appliance is operated.

2.

 

Retain Instructions:

 The safety and operating instructions should 

be retained for future reference.

3.

 

Heed Warnings:

 All warnings on the appliance should be adhered 

to.

4.

 

Follow Instructions:

 All operating and user instructions should be 

followed.

5.

 

Cleaning:

 Unplug this appliance from the wall outlet before 

 

cleaning. Use a damp cloth for cleaning. Do not use liquid cleaners 

or aerosol cleansers. 

6.

 

Do Not Use Attachments:

 Use of attachments not recommended 

by the manufacturer may cause hazards.

7.

 

Water and Moisture:

 Do not use this product near water—for 

example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet 

basement, or near a swimming pool—and the like.

8

Accessories:

 Do not place this product on an unstable cart, 

stand, tripod, bracket, or table. The product may fall, causing serious 

injury to a child or adult, and serious damage to the appliance.

9.

 

Ventilation:

 This video product should never be placed near or 

over a radiator or heat register. This video product should not be 

placed in a built-in installation such as a bookcase or rack unless 

proper ventilation is provided or the manufacturer’s instructions have 

been adhered to. Any slots or opening in the cabinet are provided for 

ventilation. To ensure reliable operation of the video product and to 

protect it from overheating, these openings must not be blocked or 

covered. Openings should never be blocked by placing the product 

on a bed, sofa, rug, or other similar surface.

10.

 

Grounding or Polarization:

 This video product is equipped 

with either a three prong plug for 110 VAC use or a two prong flat 

blade 220 volt type plug. Each type is to be inserted into only the 

type of receptacle for which they specifically designed. Do not cut 

off the round grounding pin in order to be able to fit into a two prong  

receptacle as this could cause injury and will void the warranty. 

 WARNING:

  

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE 

 

 

TO RAIN OR MOISTURE.  DO NOT OPEN THE CABINET.  

 

 

REFER SERVICING TO QUALIFIED PERSONNEL ONLY

.

 CAUTION:

  

TO PREVENT ELECTRIC SHOCK DO NOT USE THIS (POLARIZED) PLUG WITH AN EXTENSION  

 

 

CORD RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED  

 

 

TO PREVENT BLADE EXPOSURE.

 ATTENCION:

  

POUR PREVENIR LES CHOCS ELECTRIQUES, NE PAS UTILISER CETTE FICHE POLARISEE AVEC  

 

 

UN PROLONGATEUR, UNE PRISE DE COURANT OU UNE AUTRE SORTIE DE COURANT, SAUF SI  

 

 

LES LAMES PEUVENT ETRE INSEREES A FOND SANS EN LAISSER AUCUNE PARTIE A DECOUVERT.

Safeguards

Содержание CA-30RK550

Страница 1: ...Installation and Operation Manual CA 30RK550 550MHz Push Pull Headend Amplifier Operation Manual Rev 08 03 Ph 800 421 6511 www picomacom com...

Страница 2: ...r example near a bathtub washbowl kitchen sink laundry tub in a wet basement or near a swimming pool and the like 8 Accessories Do not place this product on an unstable cart stand tripod bracket or ta...

Страница 3: ...has been exposed to rain or water d If the product does not operate normally by following the operating instruction Adjust only those controls that are covered by the operating instructions An improp...

Страница 4: ...0 or CA45 550 Distribution Amplifiers The Pico Macom CA 30RK550 and CA 45RK550 are professional re broadcast grade push pull amplifiers producing signals with extremely low noise and harmonic distorti...

Страница 5: ...Beats 70 dB Composite Triple Beat 61 dB Return Loss In 16 dB Return Loss Out 16 dB RF CA 30RK550 30 dB Gain Amplifier Ordering Information Power Input 115 VAC 60 Hz 4 W Operating Temperature 10 to 50...

Страница 6: ...d CSA for safe operation of the amplifier Do not cut the ground terminal for both safety and operational reasons Connect to 108 to 125 Vac 50 60 Hz electrical outlet Back Panel 1 3 3 1 Power On LED In...

Страница 7: ...The same combining result may be accomplished by using a single PHC 24G The two PHC 12G outputs are combined via a two way splitter which is connected to a CA 30RK1000 launch amplifier The input leve...

Страница 8: ...a return merchandise authorization RMA number for the failed equipment and ask for a loaner unit We will issue an invoice for the List Price of the loaner unit plus shipping costs When you receive the...

Отзывы: