Page 4.12
8/16 TRIBUTARY DAISY CHAIN SWITCH, BALANCED 40-795/796
pickering
SECTION 4 - PROGRAMMING GUIDE
Daisy In
Rx1
T
x1
Rx2
T
x2
Rx3
Tx3
Rx4
T
x4
Rx5
T
x5
Rx6
T
x6
Rx7
Tx7
Rx8
Tx8
Rx Sel
Tx Sel
To Channels 9 to 16 (40-796 only)
To Next Page
To Next Page
SUB-UNIT 3
Ch1-8
SUB-UNIT 4
Ch1-8
SUB-
UNIT 5
Ch1
Ch2
Ch3
Ch4
Ch5
Ch6
Ch7
Ch8
SUB-UNIT 1, Ch1
SUB-UNIT 2, Ch1
SUB-UNIT 1, Ch2
SUB-UNIT 2, Ch2
SUB-UNIT 1, Ch3
SUB-UNIT 2, Ch3
SUB-UNIT 1, Ch4
SUB-UNIT 2, Ch4
SUB-UNIT 1, Ch5
SUB-UNIT 2, Ch5
SUB-UNIT 1, Ch6
SUB-UNIT 1, Ch7
SUB-UNIT 2, Ch6
SUB-UNIT 2, Ch7
SUB-UNIT 1, Ch8
SUB-UNIT 2, Ch8
RL45
RL44
RL43
RL46
RL40
RL39
RL38
RL37
RL34
RL33
RL32
RL31
RL28
RL27
RL26
RL25
RL22
RL21
RL20
RL19
RL16
RL15
RL14
RL13
RL10
RL9
RL8
RL7
RL4
RL3
RL2
RL1
RL48
RL47
RL42
RL41
RL36
RL35
RL30
RL29
RL24
RL23
RL18
RL17
RL12
RL11
RL6
RL5
RL111
RL110
RL108
RL107 RL101
RL104
RL102
RL103
RL126
RL125
RL123
RL122 RL116
RL119
RL117
RL118
NOTE: EACH SWITCH PATH REPRESENTS A TWO POLE CONNECTION
DAISY CHAIN FOR LOW QUALITY / BANDWIDTH
MEASUREMENTS E.G. BERT
MUX PATHS FOR HIGH QUALITY / BANDWIDTH
MEASUREMENTS E.G. RETURN LOSS / PULSE MASK
CONNECTIONS T
O TEST
EQUIPMENT
CONNECTIONS T
O
UNITS
UNDER TEST
40-795/796 Signal Routing Examples
Figure 4.4 - Routing Example 1: Channel 1 connected to test equipment,
all other channels daisy chained