background image

Page 3.2

RF SWITCHING MODULE  40-710

pickering

SECTION 3 - INSTALLATION

Page 3.2

REED RELAY MODULE 40-110/115/120/125

pickering

SECTION 3 - INSTALLATION

SOFTWARE INSTALLATION

First install the appropriate Pickering PXI switch card drivers by running the installer program Setup.exe (provided 

in a compressed zip file), either from the CD-ROM supplied, or by downloading the latest version from our website  

pickering

test

.com

  -  the  recommended  method.  Setup  is  accompanied  by  a  ReadMe  file  containing 

additional installation information. A single installation covers all cards in the System 40, System 45 and System 

50 ranges.
When installation completes, the installed drivers’ ReadMe file is offered for display. It can also be displayed 

later using a shortcut on the Programs>>Pickering menu.
If  you  are  not  a  LabVIEW  user  you  should  choose  the  “full”  version,  and  once  that  has  been  installed  run 

the LabVIEW Runtime Engine installer via the shortcut on the Programs>>Pickering menu. In the absence of 

LabVIEW the Runtime Engine is required to support the Pickering Test Panels application.

!

HARDWARE INSTALLATION 

ELECTRICAL CONNECTION (CHASSIS)

1.  The chassis must be electrically installed in accordance with local regional electrical codes by a qualified 

engineer.

2.  The chassis must be grounded.

Electrostatic discharge can damage the components on the module. To avoid such damage in handling the  

 

board refer to page VII.
 

Ensure that there is adequate ventilation.
 

The module should be installed in accordance with the following procedure:

 

1.  Ensure that the system is turned OFF but still connected to mains so that it remains grounded.
2. Choose an appropriate slot in the rack.
3. Remove the blanking plate for the chosen slot.
4.  Ensure that the injector/ejector handle is in its downward position. Align the module with the card guides on 

the top and bottom of the slot. 

 

Do not raise the injector/ejector handle whilst inserting the module as the module will not insert properly.

5.  Hold the handle whilst slowly sliding the module into the card guides until the handle catches on the injector/

ejector rail (refer to Figure 3.1).

6.  Raise  the  injector/ejector  handle  until  the  module  firmly  seats  into  the  backplane. The  front  panel  of  the 

module should be flush with the front panel of the chassis.

7.  Secure the front panel of the module using both screws to the chassis front panel mounting rails.
8.  In a system employing a remote control interface to connect an external controller to a PXI chassis or to link 

multiple chassis, power-up the system as follows:

a.  For a system comprising an external controller and one chassis, power up the chassis before powering up 

the external controller.

b.  For a system comprising more than one chassis, turn ON the last chassis in the system followed by the 

penultimate, etc, and finally turn ON the external controller or chassis containing the system controller.

9.  For Pickering Interfaces modular LXI installation there is no requirement to use any particular power up 

sequence.

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание PXI 40-710

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...TCHING MODULE 40 710 pickering Issue 6 2 May 2017 User Manual RF Relay Module Model No 40 710 pickeringtest com pickering Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www...

Страница 3: ...this publication may be reproduced transmitted transcribed translated or stored in any form or by any means without the written permission of Pickering Interfaces Technical details contained within th...

Страница 4: ...relevant environmental laws and regulations and reduce wastes and releases to the environment Pickering Interfaces aims to design and operate products in a way that protects the environment and the h...

Страница 5: ...UTION An appropriate safety instruction should be followed or caution to a potential hazard exists Refer to the relevant instructions detailed within the product manual HEAVY If this product is heavy...

Страница 6: ...Pre Operation Checks 3 1 Hardware Installation 3 2 Software Installation 3 2 Testing Operation 3 3 Section 4 Programming Guide 4 1 Programming Options For Pickering PXI Cards 4 1 Module Architecture 4...

Страница 7: ...Page VI RF SWITCHING MODULE 40 710 pickering THIS PAGE INTENTIONALLY BLANK Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 8: ...om equipment using these devices must be earthed by a wrist strap and a resistor at the point provided on the equipment 2 Soldering irons used during the repair operations must be low voltage types wi...

Страница 9: ...Page VIII RF SWITCHING MODULE 40 710 pickering THIS PAGE INTENTIONALLY BLANK Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 10: ...i directional with very low insertion loss suitable for handling signals up to 2 5GHz Applications include aerial switching routing high frequency signals into oscilloscopes and analysers Available wi...

Страница 11: ...g paths for parameter 40 710 514 50 SMB typical insertion loss plots for all NO and NC inputs 40 710 514 50 SMB typical VSWR plots for all NO and NC inputs 40 710 514 50 SMB typical isolation plots fo...

Страница 12: ...C typical VSWR plots for all NO and NC inputs 40 710 704 75 BNC typical isolation plots for all NO and NC inputs 40 710 704 75 BNC typical crosstalk plots between neighbouring channels 40 710 704 75 B...

Страница 13: ...VDC Max Switching Current 0 5A Nominal Switching Capacity 0 01A 24VDC 10W 1 2GHz Initial On Path Resistance 200m Off Path Resistance 1x108 Thermal Offset 20 V Expected Life Mechanical 1x106 ops Expect...

Страница 14: ...es LXI Modular Chassis For information on driving your switching solution in an LXI environment refer to the LXI Product Guide PXI CompactPCI Compliance The module is compliant with the PXI Specificat...

Страница 15: ...age 1 6 RF SWITCHING MODULE 40 710 pickering SECTION 1 TECHNICAL SPECIFICATION THIS PAGE INTENTIONALLY BLANK Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 16: ...opulated with changeover RF relays The relays are energised via control signals from relay driver U10 The relay driver is addressed by PCI bridge U1 via output register U8 to output the required signa...

Страница 17: ...Page 2 2 RF SWITCHING MODULE 40 710 pickering SECTION 2 TECHNICAL DESCRIPTION THIS PAGE INTENTIONALLY BLANK Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 18: ...nnect with Ensure the chassis is not connected to the electrical supply 3 Ensure that the designated area for the chassis containing the module is of flat and solid construction to withstand and suppo...

Страница 19: ...ation The module should be installed in accordance with the following procedure 1 Ensure that the system is turned OFF but still connected to mains so that it remains grounded 2 Choose an appropriate...

Страница 20: ...t menu Start Menu Pickering Interfaces Ltd General Soft Front Panel A selector panel will appear listing all installed Pickering PCI PXI or LXI switch cards and resistor cards Click on the card you wi...

Страница 21: ...Page 3 4 RF SWITCHING MODULE 40 710 pickering SECTION 3 INSTALLATION THIS PAGE INTENTIONALLY BLANK Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 22: ...and Pilpxi documents are included in the Pipx40vpp software installation IVI Driver for Windows pi40iv The pi40iv IVI Interchangeable Virtual Instrument driver supports all Pickering Interfaces PXI sw...

Страница 23: ...ive driver is also available Once again this may be used for both LXI and PXI card control SOAP Pickering LXI products include a SOAP interface which is usable from a wide variety of platforms and lan...

Страница 24: ...o NO4 The 40 710 utilises 4 SPDT relays In the default state all relays are open circuit Energising a particular relay creates a signal path between the C and A terminals The relay module s switching...

Страница 25: ...ld the entire pattern ViUInt32 data 1 data 0 1 Sets lowest bit to 1 Ch1 relay pipx40_setChannelPattern vi sub_unit data data 0 0x4 Sets 3rd bit Ch3 relay All other relays are set to off pipx40_setChan...

Страница 26: ...Figure 5 1 provides Pin Outs for the Modules in the 40 710 model range pickering 1 NO 1 NC 3 NC 4 C 2 C 3 NO 1 C 2 NO 4 NO 4 NC 2 NC 3 C pickering 1 NC 2 NC 3 NC 4 NC 1 C 2 C 3 C 4 C 1 NO 2 NO 3 NO 4...

Страница 27: ...Page 5 2 RF SWITCHING MODULE 40 710 pickering SECTION 5 CONNECTOR INFORMATION THIS PAGE INTENTIONALLY BLANK Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 28: ...I configuration highlighting any potential configuration problems Specific details of all installed Pickering switch cards are included All the installed Pickering switch cards should be listed in the...

Страница 29: ...RF SWITCHING MODULE 40 710 Page 6 2 pickering SECTION 6 TROUBLE SHOOTING THIS PAGE INTENTIONALLY BLANK Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Страница 30: ...nterfaces Modular LXI Chassis such as the 60 102B and 60 103B no module software update is required If the module was introduced after the LXI chassis was manufactured the module may not be recognized...

Страница 31: ...1 C10 C12 R3 C15 C17 U5 U8 U6 U9 C18 C11 C1 R1 R2 U4 U7 C6 C4 C20 U11 U2 C14 C2 U3 C13 C12 FM FM C16 LD1 LD2 LD3 LD4 LD5 LD6 LD7 LD8 U10 C19 GND GND GND 5V HD1 HD2 HD3 HD4 HD5 HD6 HD7 HD8 HD9 HD10 HD1...

Страница 32: ...2 4 1 2 1 7 2 3 4 COM 5 8 C23 R16 R17 R19 R18 MUX 2 MUX 1 J1 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14 R15 C7 C5 C3 C24 C21 C26 C25 C22 C8 C9 U1 R18 R17 R16 Q1 C10 C12 R3 C15 C17 U5 U8 U6 U9 C18 C11 C1 R1...

Страница 33: ...ITCHING MODULE 40 710 pickering SECTION 7 MAINTENANCE INFORMATION Figure 7 3 RF Switching Modules 40 710 504 40 710 514 H1 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www...

Страница 34: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Отзывы: