background image

SECTION 6 - PARTS LIST 

Page 6.3

VERY HIGH DENSITY MULTIPLEXER MODULE 40-670

pickering

R4
R5
R6
R7
R8

R9

R10
R11
R12
R13
R14
R15

pickerin

g

J1

J2

LINK AREA (FACTORY SET)

LINK AREA

(FACTORY SET)

R

L1

R

L2

R

L3

R

L4

R

L5

R

L6

R

L7

R

L8

R

L9

R

L1

0

R

L1

1

R

L1

2

R

L1

3

R

L1

4

R

L1

5

R

L1

6

R

L1

7

R

L1

8

R

L1

9

R

L2

0

R

L2

1

R

L2

2

R

L2

3

R

L2

4

R

L2

5

R

L2

6

R

L2

7

R

L2

8

R

L2

9

R

L3

0

R

L3

1

R

L3

2

R

L3

3

R

L3

4

R

L3

5

R

L3

6

R

L3

7

R

L3

8

R

L3

9

R

L4

0

R

L4

1

R

L4

2

R

L4

3

R

L4

4

R

L4

5

R

L4

6

R

L4

7

R

L4

8

R

L4

9

R

L5

0

R

L5

1

R

L5

2

R

L5

3

R

L5

4

R

L5

5

R

L5

6

R

L5

7

R

L5

8

R

L5

9

R

L6

0

R

L6

1

R

L6

2

R

L6

3

R

L6

4

R

L6

5

R

L6

6

R

L6

7

R

L6

8

R

L6

9

R

L7

0

R

L7

1

R

L7

2

R

L7

3

R

L7

4

R

L7

5

R

L7

6

R

L7

7

R

L7

8

R

L7

9

R

L8

0

R

L8

1

R

L8

2

R

L8

3

R

L8

4

R

L8

5

R

L8

6

R

L8

7

R

L8

8

R

L8

9

R

L9

0

R

L9

1

R

L9

2

R

L9

3

R

L9

4

R

L9

5

R

L9

6

R

L1

00

R

L9

9

R

L9

8

R

L9

7

C22

C1

C3

C4

C21

C20

U1

C5

C19

C6

C7

C8

C9

C14

C15

C31

C27

C23

C32

C28

C24

C33

C29

C25

C34

C30

C26

U8

U9

U10

U11

U12

U13

U14

U15

U16

U17

U18

U19

RL101
RL102

U20

U6

U5

U3

U2

U4

C17

C2

C10

C16

C13

C12

C11

C18

U7

R3

R1

R2

C35

R

L9

7a

Figure 6.1 - Multiplexer Module: Component Layout

Содержание 40-670

Страница 1: ...derutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In s...

Страница 2: ...es pickeringswitch com Pickering Interfaces Inc 966 SW 6th Street Grants Pass Oregon 97526 USA Tel 541 471 0700 Fax 541 471 8828 E Mail ussales pickeringswitch com Pickering Interfaces GmbH Buchenstra...

Страница 3: ...ERFACES ALL RIGHTS RESERVED No part of this publication may be reproduced transmitted transcribed translated or stored in any form or by any means without the written permission of Pickering Interface...

Страница 4: ...cts serviced and repaired outside of the warranty period are warranted for ninety days Extended warranty and service are available Please contact Pickering Interfaces by phone fax the website or via e...

Страница 5: ...Page iv pickering VERY HIGH DENSITY MULTIPLEXER MODULE 40 670 THIS PAGE INTENTIONALLY BLANK...

Страница 6: ...ii Technical Support and Warranty iii Contents this page v Section 1 Introduction 1 1 Section 2 Connector Pin Outs 2 1 Section 3 Programming 3 1 Section 4 Fault Diagnosis 4 1 Section 5 Technical Speci...

Страница 7: ...Page vi pickering VERY HIGH DENSITY MULTIPLEXER MODULE 40 670 THIS PAGE INTENTIONALLY BLANK...

Страница 8: ...uired The Multiplexer Module is provided in the following con gurations typical schematics are provided in Figure 1 1 Single Mode V H D MUX 198 Channel 1 Pole 40 670 022 198 1 Multi Mode H D 99 Channe...

Страница 9: ...22 198 Channel 1 Pole Multiplexer Isolation Switches Common 1 2 1 1 2 2 2 1 99 2 99 1 40 670 022 99 Channel 2 Pole Multiplexer GND 1 2 99 GND GND GND C 40 670 021 S 99 Channel Screened Multiplexer Cha...

Страница 10: ...are energised via control signals from storage registers U8 to U20 The storage registers are addressed by PCI bridge U1 to output the required signal Module con guration is determined by hardwired li...

Страница 11: ...Page 1 4 SECTION 1 INTRODUCTION VERY HIGH DENSITY MULTIPLEXER MODULE 40 670 pickering THIS PAGE INTENTIONALLY BLANK...

Страница 12: ...30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82...

Страница 13: ...27 126 125 124 123 122 121 120 119 118 117 116 115 114 113 112 111 110 109 108 107 106 105 104 103 102 101 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81...

Страница 14: ...2 1 74 1 76 1 78 1 80 1 82 1 84 1 86 1 88 1 90 1 92 1 94 1 96 1 98 1 99 1 1 1 3 1 5 1 7 1 9 1 11 1 13 1 15 1 17 1 19 1 21 1 23 1 25 1 27 1 29 1 31 1 33 1 35 1 37 1 39 1 41 1 43 1 45 1 47 1 49 1 51 1 5...

Страница 15: ...56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30...

Страница 16: ...S1 S1 S1 S1 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197...

Страница 17: ...33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1 1 1 3 1 5 1 7 2 1 2 3 2 5 2 7 3 1 3 3 3 5 3 7 4 1 4 3 4 5 4 7 5 1 5 3 5 5 5 7 6 1 6 3 6 5 6 7 7 1 7 3 7 5 7...

Страница 18: ...VERY HIGH DENSITY MULTIPLEXER MODULE 40 670 pickering SECTION 3 PROGRAMMING Please refer to the PXI Software manual for programming information This manual is available on the Pickering Interfaces web...

Страница 19: ...Page 3 2 VERY HIGH DENSITY MULTIPLEXER MODULE 40 670 SECTION 3 PROGRAMMING pickering THIS PAGE INTENTIONALLY BLANK...

Страница 20: ...TIPLEXER MODULE 40 670 pickering SECTION 4 FAILURE DIAGNOSIS There is no self test facility provided on the 40 670 series Multiplexer Modules Failure diagnosis is limited to identi cation of faulty re...

Страница 21: ...Page 4 2 SECTION 4 FAILURE DIAGNOSIS VERY HIGH DENSITY MULTIPLEXER MODULE 40 670 pickering THIS PAGE INTENTIONALLY BLANK...

Страница 22: ...t 0 5A Max Carry Current 1 2A Path Resistance On Single Module 300m Off Single Module 109 Differential Thermal Offset 5 V Capacitance 022 version Open Channel 6pF Channel to Channel 15pF Crosstalk 022...

Страница 23: ...Page 5 2 SECTION 5 SPECIFICATION VERY HIGH DENSITY MULTIPLEXER MODULE 40 670 pickering THIS PAGE INTENTIONALLY BLANK...

Страница 24: ...ON 6 PARTS LIST Page 6 1 VERY HIGH DENSITY MULTIPLEXER MODULE 40 670 pickering SECTION 6 PARTS LIST The following pages provide parts lists and a component layout diagram for the 40 670 Multiplexer Mo...

Страница 25: ...0 7 6 0 4 1 0 1 6 9 L R o t 1 L R 2 0 1 9 2 1 L R C D 1 0 5 5 A 1 S 9 0 1 Y A L E R 8 9 6 1 0 1 2 2 0 0 7 6 0 4 2 0 1 L R o t 1 L R 1 1 1 L R C D 1 5 A 2 S 9 0 1 Y A L E R 2 0 1 8 0 1 S 1 2 0 0 7 6 0...

Страница 26: ...RL41 RL42 RL43 RL44 RL45 RL46 RL47 RL48 RL49 RL50 RL51 RL52 RL53 RL54 RL55 RL56 RL57 RL58 RL59 RL60 RL61 RL62 RL63 RL64 RL65 RL66 RL67 RL68 RL69 RL70 RL71 RL72 RL73 RL74 RL75 RL76 RL77 RL78 RL79 RL80...

Страница 27: ...Page 6 4 SECTION 6 PARTS LIST VERY HIGH DENSITY MULTIPLEXER MODULE 40 670 pickering THIS PAGE INTENTIONALLY BLANK...

Страница 28: ...ollowing precautions when handling these devices in their unterminated state or sub units containing these devices 1 Persons removing sub units from an equipment using these devices must be earthed by...

Страница 29: ...tilation until a normal pulse is felt and colour improves WHEN NORMAL BREATHING COMMENCES PLACE CASUALTY IN RECOVERY POSITION Keep casualty at rest Remove on a stretcher Watch closely particularly for...

Страница 30: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Отзывы: