Page 1.2
HIGH POWER RELAY MODULE 40-170
pickering
SECTION 1 - TECHNICAL SPECIFICATION
High Power Relay Module – 40-170
pickering
test
.com
Specifications
Switching Specification - SPST (40-170-001)
Contact Type:
Silver Alloy
Cold Switching Capacity
Maximum Current:
Maximum Voltage:
30A
30VDC/250VAC R.M.S.*
Hot Switching Capacity
Maximum Current:
Maximum Voltage:
Maximum Power:†
Minimum Switching Capacity:
30A
30VDC/250VAC R.M.S.*
900W/7500VA
100mA, 5VDC
Maximum Standoff Voltage:
Initial On Path Resistance:
Off Path Resistance:
Bandwidth (50Ω)
600VDC*
100mΩ
>1x10
8
Ω
10MHz
Operate Time:
30ms typical
Expected Life (operations)
- resistive load
Mechanical Life:
At Maximum Switch Capacity:
>1x10
7
(DC), >5x10
6
(AC)
>1x10
5
* For full voltage rating, signal sources to be switched must be fully
isolated from mains supply and safety earth.
† For variation of maximum hot switching capacity of voltage with
current refer to plot.
Power Requirements
+3.3V
+5V
+12V
-12V
0
200mA
340mA
0
Mechanical Characteristics
Double slot 3U PXI (CompactPCI card).
Module weight: 400g (40-170-001).
420g (40-170-002).
3D models for all versions in a variety of popular file formats are
available on request.
Connectors
PXI bus via 32-bit P1/J1 backplane connector.
Signals via front panel male 8-pin power D-Type connector, for pin
outs please refer to the operating manual.
Relay Type
The 40-170 is fitted with electro-mechanical power relays with
silver alloy contacts.
Switching Specification - DPST (40-170-002)
Contact Type:
Silver Alloy
Cold Switching Capacity
Maximum Current:
Maximum Voltage:
20A
30VDC/250VAC R.M.S.*
Hot Switching Capacity
Maximum Current:
Maximum Voltage:
Maximum Power:†
Minimum Switching Capacity:
20A
30VDC/250VAC R.M.S.*
600W/5000VA
100mA, 5VDC
Maximum Standoff Voltage:
Initial On Path Resistance:
Off Path Resistance:
Bandwidth (50Ω)
600VDC*
100mΩ
>1x10
8
Ω
10MHz
Operate Time:
30ms typical
Expected Life (operations)
- resistive load
Mechanical Life:
At Maximum Switch Capacity:
>1x10
7
(DC), >5x10
6
(AC)
>1x10
5
* For full voltage rating, signal sources to be switched must be fully
isolated from mains supply and safety earth.
† For variation of maximum hot switching capacity of voltage with
current refer to plot.
40-170-002 (DPST) Current/Operating Life Curve
40-170-001 (SPST) Current/Operating Life Curve
30VDC / 250VAC Resistive Load
30VDC / 250VAC Resistive Load
Содержание 40-170
Страница 2: ...pickeringtest com Issue 4 3 January 2020 40 170 User Manual PXI High Power Relay Module ...
Страница 7: ...Page VI HIGH POWER RELAY MODULE 40 170 pickering THIS PAGE INTENTIONALLY BLANK ...
Страница 21: ...Page 3 4 HIGH POWER RELAY MODULE 40 170 pickering SECTION 3 INSTALLATION THIS PAGE INTENTIONALLY BLANK ...
Страница 25: ...Page 4 4 HIGH POWER RELAY MODULE 40 170 pickering SECTION 4 PROGRAMMING GUIDE THIS PAGE INTENTIONALLY BLANK ...
Страница 29: ...HIGH POWER RELAY MODULE 40 170 Page 6 2 pickering SECTION 6 TROUBLE SHOOTING THIS PAGE INTENTIONALLY BLANK ...