PicC Electronics SMS Alert 9 Скачать руководство пользователя страница 8

 

 

SMS Alert Alarm / Plus

 

 

Page 8 of 8  

 

 
 

 
 

 

 
 

 

 
 

 

 
 

 

 
 

 
 

 

 
 

 

 
 

 

 
 

 
 

Thank you for using this product! 

 
Please note the following: 

 

1.  Additional requests can be emailed to [email protected]
2.  For software/hardware updates, please visit 

www.smsalert.co.za

3.  For support, phone us on 083 235 4916. Please note that your first point of call must be your 

supplier or installer. If they are unable to help you, we will be more than happy to assist. 

 

 

 
 

Disclaimer: 

PicC Electronics will not be held responsible for loss, damage or injury to any persons, company or 

legal entity using SMS Alert. It is also recommended that the SMS Alert is tested on a regular basis, for 

example by sending a status request to it.

 

 

 
 
[1,2,3,8] [7,4,5,6]

 

SMS Command Summary 

 

1234 B

   - To let the SMS Alert report to the 1

st

 phone (toggle) 

1234 C

   - Report to 2

nd

 phone (toggle) 

1234 D

   - Report  to 3

rd

 phone (toggle) 

1234 E

   - Report to 4

th

 phone (toggle) 

1234 R

   - To request the status of the SMS Alert  

1234 A ON

 – To switch relay A on (and the same for B and C) 

1234 A OFF

 – To switch relay A off (and the same for B and C) 

1234 AP

- Pulse Relay A once for 500ms (and the same for B and C) 

1234 APP 

- Pulse Relay A 10 times (Pepper gas) 

1234 01

-  To toggle Missed Call function on or off 

1234 02

 – To toggle the SMS function on or off (Only applicable to SMS Alert Alarm) 

1234 02

 – To toggle the dual trigger mode (SMS Alert 1 only) 

1234 03

 – To toggle the inputs to trigger between negative apply (default) and negative 

remove.  

 

Program Input Strings (max 19 characters) 

1234 1   

- String 1 (Input 1) 

1234 4   

- String 4 

1234 5   

- String 5 

1234 6   

- String 6 

1234 7   

- String 7 

1234 8   

- String 8 

1234 9    

- String 9 (panic) 

 

*String 2 and 3 not programmable. Can be changed by manufacturer.

 

 

Содержание SMS Alert 9

Страница 1: ...ess control and monitoring etc SMS Alert 1 SMS Alert 1 works on the same principle than SMS Alert 9 but it is smaller and less expensive It is a programmable dual single input and 1 switched relay outputdevice The dimensions are approximately 155mm x 75mm x 55mm It reports tofour cellphones Input 1 Dual option Can be set to send a SMS on both aNegative apply or Negative remove trigger The SMS that...

Страница 2: ...ser Manual SMS Alert Version 7 7 Input 1 ZONE 1 Input 2 ZONE 2 Input 3 ZONE 3 Input 4 ZONE 4 Input 5 ZONE 5 Input 6 ZONE 6 Input 7 ZONE 7 Input 8 ZONE 8 Input 9 Panic Features ARM DISARM STATUS LED SIREN OUTPUT RELAY OUTPUT ARM DISARM via KEY SWITCH or SMS ...

Страница 3: ...There must be a space between 1234 and b 9 The SMS Alert will respond by sending its status back to you e g INPUT ON B 00000000000 Ensure that the character B appears in the SMS How to receive your first SMS 10 ARM Apply a positive pulse to the Key switch input for 50ms milliseconds and relay C will latch switch on or off to indicate that the SMS Alert is armed You will receive an ARMED SMS A pilo...

Страница 4: ...SMS 1234 a off and the same for 1234 b off 1234 c off To switch all relays on SMS 1234 all on or else 1234 all off To pulse relay A SMS 1234 ap and the same for 1234 bp 1234 cp Programming the input SMS strings SMS characters You are able to programme the SMS messages you would like to receive on your cellphone s when your alarm goes off or when the inputs of the SMS Alert are triggered Each input...

Страница 5: ...ert to enable it to change the code 2 Send 1234 CODE to the SMS Alert The SMS Alert will SMS back CODE 3 You can now SMS your selected 4 digit numeric code e g 5678 This code is used as a prefix to operate all commands 3 Panic Input This input is always on and does not depend on the Key Switch 4 Key Input This input enables or disables the 8 inputs The Key Input is on by default because of the red...

Страница 6: ...sted in South Africa only Technical Specifications 1 Power supply Minimum of 12 volt DC 500mA milliamps Standby is 30 50 mA You must at least have a battery pack inline Auxiliary outputs on panels do not provide sufficient power 2 Number of cellphone users 1 4 3 Relay contacts 5A Use additional external relays for more current It is not recommended to run 220 V through the relays 4 Inputs 1 to 8 T...

Страница 7: ...rial touching wires No wires must touch the aerial of the phone The SMS Alert won t work inside a metal container Use our magnetic external extension aerials for weak reception 4 Insert SIM card error Remove the SIM card and slightly twist the SIM card contacts more upward with a small screwdriver 5 Other equipment used in conjunction with SMS Alert It is not recommended that other receivers trans...

Страница 8: ...MS Alert report to the 1st phone toggle 1234 C Report to 2nd phone toggle 1234 D Report to 3rd phone toggle 1234 E Report to 4th phone toggle 1234 R To request the status of the SMS Alert 1234 A ON To switch relay A on and the same for B and C 1234 A OFF To switch relay A off and the same for B and C 1234 AP Pulse Relay A once for 500ms and the same for B and C 1234 APP Pulse Relay A 10 times Pepp...

Отзывы: