SMS Alert PCB top view 

     

 

 

Installation advice / help  

1.

 

Do not connect the power of the SMS Alert to an 

auxiliary 12V power output

. It is best to connect the 

SMS Alert 

directly to, and within 1 meter from the 12V battery 

where the power is best regulated. 

2.

 

External  magnetic  antennas  are  available  for 

better  reception. 

It  may  be  required  where  the  signal 

reception is poor, or where the system is installed in a metal container that prevents signal reception. 

3.

 

Try  to  keep  the  SMS  Alert  at  least 

30cm

  away  from  other  equipment  like 

receivers,  transformers

energisers,

 etc., that may cause interference. 

4.

 

It is strongly recommended that 

Mylar

 

cable

 (shielded with foil) is used for 

Electric Fence

 applications. 

Both the power and inputs on the SMS Alert must use Mylar cable. Without this cable the SMS Alert might 
seem to work fine, but problems may be experienced 2 weeks later. Also ensure 

high voltage wires

 do 

not cross the SMS Alert wires. 

5.

 

The SMS Alert should work 

outside of SA

, however limited testing was done for this purpose. 

6.

 

The SMS Alert is 

not built for a specific alarm panel

 and may have other applications like pump control 

and monitoring, cable theft, electric fence monitoring, opening/closing a gate, etc. 

7.

 

In very few cases, when SMS commands are 

not recognised by the SMS Alert

, check that the user’

Text  Message  settings  on  his/her  cellphone  are  set  to  ‘Text  mode’  or  ‘Full  Character  Support’  (under 

message options). 

8.

 

It is recommended that the SMS Alert be 

tested 

on a regular basis, for example by sending it a status 

request (1234 r). This will also  cause a transaction that may prevent the SIM-card from expiring if it is 
seldom used. 

9.

 

Always keep the inside of the 

SMS Alert box clean

, with the minimum amount of unnecessary wires. 

10.

 

Do not apply 

excessive force

 with tools on the connector terminals to prevent break-offs. 

11.

 

To keep your number active, you should send an SMS (1234 r) at least once 

every 7 months (Vodacom) 

or 3 months (MTN), 

or as specified by your cellphone service provider. 

 

 
 

 Input 9 

Key input  

 Input 8 

 Input 7 

 Input 6 

 Input 5 

 Input 4 

 Input 3  

 Input 2  

 Input 1  

 

 
Inputs 1-8: Negative or 

PositiveTRIP via Jumper 
 

The other inputs are all  

Negative trip

 

Input 10 

Input 11 
Input 12 

Input 13 
Input 14 

Input 15 

n/a 
n/a 

n/a 

 

 