![PicC Electronics SMS ALERT 15 Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/picc-electronics/sms-alert-15/sms-alert-15_user-manual_1554882001.webp)
Copyright Reserved ©: PicC Electronics (2019)
Page 1 of 6
For technical support, contact: 011 202 5884 or 083 235 4916.
SMS ALERT 15
User Manual
Features:
-
15 non-user renamable inputs (input names must be specified on order). Alternative methods can be
discussed with supplier
-
All inputs reports to 10 user and 1 technician user
-
Inputs can be single or dual state trip e.g. between 15 and 30 different SMS can be sent.
Quick Start Steps
1.
Preparing SIM-card
- Buy an MTN, Vodacom or Cell C starter pack (prepaid or contract) and RICA it
(you need your id and proof of address for this). Ensure that you can send an SMS out from the SIM-card,
before you put it in the SIM-card slot of the SMS Alert. Making a call to the SMS Alert only is not sufficient
to test the SIM-card. PIN-code request must be deactivated before you insert the SIM-card into the SMS
Alert.
2.
Airtime
- Ensure that the SIM-card has sufficient credit. Load airtime if necessary.
3.
Insert the SIM-card
into the SIM-card slot. Apply 12VDC.
4.
The green LED will flash once when an SMS is sent.
5.
SMS
1234 b
from your cellphone to the SMS Alert. Note the
yellow LED
will light up when B is active.
This step tells the SMS Alert where to send SMSe when inputs are tripped.
There must be a space
between
1234
and
b. If you SMS 1234 b again, you will cancel user B. If you SMS 1234 b again, you
will reload user B. (In other words you will toggle it on & off).