![PIAB C 1200 Series Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/piab/c-1200-series/c-1200-series_troubleshooting-manual_1554534051.webp)
VACUUM CONVEYORS
51
TROUBLESHOOTING GUIDE: LEVEL DETECTOR 24 VDC, PART # 01.00.267
TROUBLESHOOTING GUIDE: INJECTION UNITS, PART # 34.04.019 - 34.04.023
Problem
Possible Causes
Possible Solutions
Conveyor will not turn on
X
Air is shut off·
X
Product is covering the sensor on the Level
Detector(giving a false high level signal
X
No 24 VDC going into the level detector
X
Incorrect pressure coming out of port #8 on
CU controller
X
Air signal tubing is not properly installed
into level detector or CU controller
X
Level sensor is malfunctioning
X
Connect the air supply to the pump
(40-100 psi)
X
Connect the 6mm tubing to the mani-
fold of the pump and the 6mm connec-
tion on the control unit
X
Open conveyor and remove any prod-
uct that is covering the level detector
X
Connect power supply / If there is a
loss of power the CU controller will
shut down and need to be manually
reset
X
Place an air pressure gauge into port #8
on the CU controller and verify air
pressure venting from port #8 is 30 - 40
psi
X
Push tubing into each respective fitting
checking to make sure there is no air
leaking from each fitting
X
Call PIAB, 1-800-321-7422 to arrange
repair or replacement
Problem
Possible Causes
Possible Solutions
Injection unit will not cycle
X
Air is shut off
X
Pinch valve remains open
X
Vacuum switch does not read any vacuum
X
Pinch valve remains closed
X
Pinch valve bladder is worn or ruptures
X
Connect the air supply to the unit (87
psi)
X
Connect the 6mm tubing to the air in
port on the switch control box
X
Air supply to the injection unit is
greater than 87 psi, decrease air supply
X
Verify that 4mm tubing is connected
between the vacuum port on the pump
(see diagram) and the vacuum port on
the switch control box
X
Adjust vacuum switch to lower vac-
uum level by opening switch control
box and turn knob on top of vacuum
switch until pinch valve opens
X
Call PIAB, 1-800-321-7422 to arrange
repair or replacement
Содержание C 1200 Series
Страница 1: ...VACUUM CONVEYING C Series Conveyor Troubleshooting Guide www piab com ...
Страница 7: ...VACUUM CONVEYORS 7 CONNECTION EXAMPLES CONTROL UNIT CU 1A B ART NO 01 04 550 ART NO 01 04 552 ...
Страница 8: ...VACUUM CONVEYORS 8 CONTROL UNIT CU 1A B WITH FLUIDISATION ART NO 01 04 550 ART NO 01 04 552 ...
Страница 10: ...VACUUM CONVEYORS 10 CONTROL UNIT CU 1A B USDA ART NO 01 04 550 ART NO 01 04 552 ...
Страница 11: ...VACUUM CONVEYORS 11 CONTROL UNIT CU 2A B ART NO 01 04 540 ART NO 01 04 548 ...
Страница 13: ...VACUUM CONVEYORS 13 CONTROL UNIT CU 2A B WITH FLUIDISATION ART NO 01 04 540 ART NO 01 04 548 ...
Страница 14: ...VACUUM CONVEYORS 14 CONNECTION EXAMPLES ...
Страница 15: ...VACUUM CONVEYORS 15 VALVE UNIT VCC EP VALVE UNIT VCC EP WITH FLUIDISATION ...
Страница 18: ...VACUUM CONVEYORS 18 FILTER REPALCEMENT 1 2 3 4 5 ...
Страница 19: ...VACUUM CONVEYORS 19 6 7 8 9 10 11 12 ...
Страница 29: ...VACUUM CONVEYORS 29 INSIDE COMPONENTS OF MLL PUMPS ...
Страница 31: ...VACUUM CONVEYORS 31 L100 CLASSIC COMPONENTS ...
Страница 38: ...VACUUM CONVEYORS 38 CONTROL UNIT CU 1B BOTTOM VALVE NC ART NO 01 04 552 ...
Страница 39: ...VACUUM CONVEYORS 39 PNEUMATIC DIAGRAM CONTROL UNIT CU 1A BOTTOM VALVE NO ART NO 01 04 550 ...
Страница 40: ...VACUUM CONVEYORS 40 CONTROL UNIT CU 1B BOTTOM VALVE NC ART NO 01 04 552 ...
Страница 41: ...VACUUM CONVEYORS 41 CONTROL UNIT CU 2B BOTTOM VALVE NC ART NO 01 04 548 ...
Страница 44: ...VACUUM CONVEYORS 44 PNEUMATIC DIAGRAM COMPONENT LAYOUT ...
Страница 45: ...VACUUM CONVEYORS 45 TIME SIGNAL DIAGRAM MOUNTING ...
Страница 50: ...VACUUM CONVEYORS 50 VALVE CONNECTIONS FOR THE VCC EP ...
Страница 53: ...VACUUM CONVEYORS 53 PNEUMATIC INJECTION VALVE ...
Страница 57: ...VACUUM CONVEYORS 57 NOTES ...
Страница 58: ...VACUUM CONVEYORS 58 NOTES ...
Страница 59: ...VACUUM CONVEYORS 59 NOTES ...