5 Installation
26
Version: 1.2.0
PZ234D
P-62x Positioners
Separate protective earth connector not available
If a separate protective earth connector is not available,
all
mounting holes marked with the
protective earth conductor symbol must be used to ensure proper connection of the
protective earth conductor.
Figure 7: Mounting hole with symbol for the protective earth conductor
Tools and accessories
Suitable protective earth conductor: Cable cross section
≥ 0.75
mm
2
Suitable screwdriver
All models except P-620 and P-621.2xx/.2U: M4 protective earth conductor screw set
(p. 14) for connecting the protective earth conductor
When mounting a P-620 and a P-621.2xx/.2U:
−
Screw set (p. 14) for fixing the positioner onto a surface
−
Suitable surface: The surface where the positioner is to be mounted must be
connected to a suitable protective earth conductor. The surfaces that make contact
with the positioner, usually the holes for accommodating the mounting screws,
must be sufficiently conductive.
Requirements
You have read and understood the general notes on installation (p. 21).
The P-62x is
not
connected to the controller.