background image

 

 

1 About this Document 

M-605 High-Precision Linear Stage 

MP45E 

Version: 1.2.0 

 

1.1

 

Objective and Target Group of this User Manual 

This manual is designed to help the reader to install and operate the M-605 Linear Positioning 

Stages. It assumes that the reader has a fundamental understanding of basic servo systems, as 

well as motion control concepts and applicable safety procedures. 

 

1.2

 

Symbols and Typographic Conventions 

The following symbols and typographic conventions are used in this user manual: 

 

CAUTION 

 

Dangerous situation 

If not avoided, the dangerous situation will result in minor injury. 

 

Actions to take to avoid the situation. 

 

 

NOTICE 

 

Dangerous situation 

If not avoided, the dangerous situation will result in damage to the equipment. 

 

Actions to take to avoid the situation. 

 

 

INFORMATION 

 

Additional information that can affect your application. 

 

Symbol / Label  Meaning 

1. 
2. 

Action consisting of several steps whose sequential order must be observed 

 

  

Action consisting of one or several steps whose sequential order is irrelevant 

24 V DC

 

Labeling of an operating element on the product 

 

Warning sign affixed to the product that refers to detailed information in this 

manual. 

 

 

1

 

About this Document 

Содержание M-605 Series

Страница 1: ...MP45E M 605 High Precision Linear Stage User Manual Version 1 2 0 Date 2019 07 02 This document describes the following products M 605 1DD Compact precision linear stage 25 mm travel range 0 1 m linea...

Страница 2: ...9 Physik Instrumente PI GmbH Co KG Karlsruhe Germany The text photographs and drawings in this manual are protected by copyright With regard thereto Physik Instrumente PI GmbH Co KG reserves all right...

Страница 3: ...livery 5 3 3 Accessories 5 3 4 Technical Features 6 3 4 1 Linear Scale Position Encoder 6 3 4 2 PWM Amplifiers 6 3 4 3 Travel Limit Sensors 6 3 4 4 Position Reference Signal Sensors 6 4 Unpacking 7 5...

Страница 4: ...able 21 10 1 2 Maximum Ratings 22 10 1 3 Ambient Conditions and Classifications 22 10 1 4 Limit Switch Specifications 23 10 2 Dimensions 24 10 2 1 M 605 1DD 24 10 2 2 M 605 2DD 25 10 2 3 M 605 AV1 26...

Страница 5: ...nual CAUTION Dangerous situation If not avoided the dangerous situation will result in minor injury Actions to take to avoid the situation NOTICE Dangerous situation If not avoided the dangerous situa...

Страница 6: ...the data storage device for the product to get the access data Downloading manuals 1 Open the website www pi ws 2 If the product was shipped with a data storage device Log into the website a Click Log...

Страница 7: ...amage to the M 605 Only use the M 605 for its intended purpose and only if it is in perfect condition Read the user manual Immediately eliminate any faults and malfunctions that are likely to affect s...

Страница 8: ......

Страница 9: ...ecision linear stage 50 mm travel range 4295 Mounting kit consisting of 4 metric screws M4x35 and a hex wrench C 815 38 Motor cable D Sub 15 3 m C 501 24050H Wide range input power supply 24 V DC 50 W...

Страница 10: ...end work with the controller s limit sense input lines The TTL output signal is active high The outer limit sensors N2 at the negative and P2 at the positive end work locally opening a relay that cut...

Страница 11: ...ith care 2 Compare the contents with the items listed in the contract and the packing list 3 Inspect the contents for signs of damage If there is any sign of damage or missing parts contact PI immedia...

Страница 12: ......

Страница 13: ...s 5 2 Mounting the M 605 M 605 stages can be mounted in any orientation horizontally or vertically To achieve the specified guiding accuracy the stages must be mounted on an even surface to avoid tors...

Страница 14: ...You have prepared the load so that it can be affixed to the mounting holes on the upper platform p 24 Tools and accessories At least 2 metric screws M4x35 Hex wrench in the scope of delivery p 5 Affix...

Страница 15: ...ents The power cord is not connected to the power socket Tools and accessories Supplied components in the scope of delivery p 5 Wide range input power supply Adapter for the power supply connection ba...

Страница 16: ......

Страница 17: ...be caught by moving parts Stop the motion immediately if a controller malfunction occurs If possible adapt the travel range limits of your mechanical system in the software you use for commanding the...

Страница 18: ...ler and the required PC software have been installed Starting and Operating the M 605 1 Start the controller see user manual for the controller 2 Configure the controller for the M 605 during startup...

Страница 19: ...he stages are operated in extremely dusty environments we recommend cleaning and greasing the ballscrew and linear bearings from time to time The time interval depends on the degree of contamination a...

Страница 20: ......

Страница 21: ...p 11 Fault Reduced positioning accuracy Possible causes Remedial measures Warped base body Mount the M 605 onto an even surface p 9 Fault Uncontrolled oscillation Possible causes Remedial measures La...

Страница 22: ......

Страница 23: ...serial numbers of all products in the system Firmware version of the controller if applicable Version of the driver or the software if applicable Operating system on the PC if applicable If possible...

Страница 24: ......

Страница 25: ...lution 0 1 0 1 m Design resolution 0 1 0 1 m Minimum incremental motion 0 3 0 3 m Unidirectional repeatability 0 1 0 1 m Bidirectional repeatability 0 2 0 2 m Accuracy 1 1 m Pitch 30 30 rad Yaw 30 30...

Страница 26: ...es 10 1 2 Maximum Ratings The M 605 positioners are designed for the following operating data Maximum operating voltage Maximum operating frequency Maximum power consumption 24 V 6 W 10 1 3 Ambient Co...

Страница 27: ...h Specifications Type Magnetic Hall effect sensors can be used with bipolar CMOS circuits Supply voltage 5 24 V GND supplied by the motor controller through the motor connector Signal output TTL level...

Страница 28: ...10 Technical Data 24 Version 1 2 0 MP45E M 605 High Precision Linear Stage 10 2 Dimensions Dimensions in mm Note that the decimal places are separated by a comma in the drawings 10 2 1 M 605 1DD...

Страница 29: ...10 Technical Data M 605 High Precision Linear Stage MP45E Version 1 2 0 25 10 2 2 M 605 2DD...

Страница 30: ...10 Technical Data 26 Version 1 2 0 MP45E M 605 High Precision Linear Stage 10 2 3 M 605 AV1...

Страница 31: ...Signal Direction 1 Control for optional motor brake 0 to 24 V Input 2 Not connected 3 PWM MAGN Input 4 5 V Input 5 PLIMIT positive limit switch Output 6 GND Limit 7 Encoder A Output 8 Encoder B Output...

Страница 32: ......

Страница 33: ...g to international national and local rules and regulations In order to fulfil the responsibility as the product manufacturer PI miCos GmbH undertakes environmentally correct disposal of all old PI mi...

Страница 34: ......

Страница 35: ...M 605 in accordance with the following European directives EMC Directive Low Voltage Directive Safety of Machinery The standards applied for certifying the conformity are listed below EMC EN 61326 1...

Отзывы: