6 Start-Up
26
Version: 1.2
MP102E
M-230 Linear Actuators
4. Connect the actuator with the controller:
a) Determine the minimum necessary cable length between the actuator and
the controller.
b) Connect the connector of the connection cable with the Sub-D socket of
the controller or a corresponding adapter (according to the determined
length, see above) either directly or by interposing an additional motor
cable.
c) Secure all connections with the integrated screws against accidental
disconnection.
d) Remove or label resulting danger areas in accordance with the valid legal
regulations and directives.
5. Start up the controller (see user manual of the controller).
6. Configure the controller using the PC software for the used actuator (see the
user manual of the controller and the PC software):
−
If you use a PI controller: select the entry in the stage database that
precisely matches the actuator version used, see the list of available
entries (p. 26).
−
If you use a controller from another manufacturer: Enter the parameters in
the corresponding PC software that precisely match the actuator version
used.
7. Start a few motion cycles for testing purposes (see user manual of the
controller).
6.2.1 M-230 Entries in the Stage Database of PI
For motor controllers from PI you can select the connected linear actuator from a
stage database in the respective PC software. The appropriate operating parameters
are thus loaded into the motor controller. You can find a detailed description in the
user manual for the motor controller or in the manual for the PC software used.