This manual is designed to help the reader to install and operate the E-650 LVPZT Amplifier for 
Multilayer Bending Actuators. It assumes that the r
eader has a fundamental understanding of 
applicable safety procedures. 
The manual describes the physical specifications and dimensions of the E-650 LVPZT Amplifier 
for Multilayer Bending Actuators as w
ell as the installation procedures which are required to put 
the associated motion system into operation. 
This document is available as PDF file. Updated releases are available via FTP or email: 
contact your Physik Instrumente sales engineer or write 

[email protected]

Conventions 

The notes and symbols used in this manual have the following meanings: 

WARNING 

Calls attention to a procedure, practice or condition which, if not 
correctly performed or adhered to, could result in injury or death. 

DANGER 

Indicates the presence of high voltage (> 50 V). Calls attention to 
a procedure, practice or condition which, if not correctly 
performed or adhered to, could result in injury or death. 

CAUTION 

Calls attention to a procedure, practice, or condition which, if not 
correctly performed or adhered to, could result in damage to 
equipment. 

 

 

Содержание E-650

Страница 1: ...ators Release 1 0 3 Date 2005 05 12 This document describes the following product s E 650 00 LVPZT Amplifier E 650 OE LVPZT OEM Amplifier Physik Instrumente PI GmbH Co KG Auf der R merstr 1 76228 Karl...

Страница 2: ...and normative documents Electromagnetic Emission EN 61000 6 3 EN 55011 Electromagnetic Immunity EN 61000 6 1 Safety Low Voltage Directive EN 61010 1 Electrical equipment which is intended to be integ...

Страница 3: ...I GmbH Co KG reserves all rights Use of said texts photographs and drawings is permitted only in parts and only upon citation of the source First printing 2005 05 12 Document Number PZ 97E Release 1 0...

Страница 4: ...document is available as PDF file Updated releases are available via FTP or email contact your Physik Instrumente sales engineer or write info pi ws Conventions The notes and symbols used in this manu...

Страница 5: ...Rear Panel Elements 6 4 Operation 7 4 1 Operating Requirements 7 4 2 Operating Modes 7 5 E 650 00 Technical Data 8 5 1 Block Diagram 8 5 2 Pin Assignment 8 5 3 E 650 PS Power Supply 9 5 4 Specificati...

Страница 6: ...Pose PCBs only on conductive surfaces such as ESD safe transport containers envelopes foam Electronic subassemblies must always be kept and transported shipped in conductive packaging Make sure that n...

Страница 7: ...cautions CAUTION Handle bender actuators ceramic elements with care Do not drop a bender actuator avoid subjecting it to any kind of mechanical shock www pi ws E 650 LVPZT Amplifier PZ 97E Release 1 0...

Страница 8: ...LCD Voltage Display Output Voltage Range 0 to 60 V One Fixed Voltage for Full Differential Voltage Control The PICMA actuators require full differential voltage control with constant voltages of 0 V a...

Страница 9: ...Amplifier for Multilayer Bender Actuators E 650 OE LVPZT OEM Amplifier for Multilayer Bender Actuators E 650 PS Power Supply ID 2580 E 650 90 OEM cable for PZT connection DB9pin open end 1 5 m www pi...

Страница 10: ...n potentiometer for DC bias 0 to 60 Volts PZT Monitor control voltage output monitor 0 10 V PZT Output DB 9 pin connector for PZT connection Control Input Analog control voltage input BNC connector Po...

Страница 11: ...id subjecting it to any kind of mechanical shock 4 1 Operating Requirements A power supply for 2A 15 VDC is required Recommended is the use of the 650 PS power supply 4 2 Operating Modes External oper...

Страница 12: ...n 1 is internally connected to pin 2 and pin 4 is internally connected to pin 5 so that the appropriate output voltages are present on both pins of such a pair in parallel It is also possible to conne...

Страница 13: ...t limitation Short circuit proof Control input voltage 0 to 10 V Output voltage 0 to 60 V one additional fixed voltage of 60 V Polarity positive DC offset setting 0 to 60 V w 10 turn pot Voltage gain...

Страница 14: ...s only on conductive surfaces such as ESD safe transport containers envelopes foam Electronic subassemblies must always be kept and transported shipped in conductive packaging Make sure that no conduc...

Страница 15: ...s we strictly advise you to follow the General Accident Prevention Regulations All work done with and on the devices described here requires adequate knowledge of handling high voltages CAUTION Handle...

Страница 16: ...rage output current 5 ms 60 mA per channel Current limitation Short circuit proof Control input voltage 0 to 10 V Output voltage 0 to 60 V one additional fixed voltage of 60 V Polarity positive Voltag...

Страница 17: ...E 650 OE OEM LVPZT Amplifier www pi ws E 650 LVPZT Amplifier PZ 97E Release 1 0 3 Page 13 6 3 E 650 OE Pin Assignment Fig 6 E 650 OE Pin Assignment...

Отзывы: