2 To Consider Before Installation
Read this manual very carefully before installing and operating the MR 8.
Observe the safety instructions in the following chapter!
2.1 Qualified Personnel
Design, installation and operation of systems using the MR 8 may only be
performed by qualified and trained personnel.
These persons should be able to recognize and handle risks emerging from
electrical, mechanical or electronical system parts.
WARNING !
By persons without the proper training and qualification damages to devices and
persons might result!
2.2 Safety Instructions
1. Connect the MR 8 to
PE
.
Use the PE screw, which is fixed on the right side of the device.
2. The MR 8 must only be operated if the unit housing and motor housing are
connected to protective earth.
3. Motor and signal cables must be shielded. The cable shielding must be
connected conductively to the housing.
4. The
transformer
must
be constructed with reinforced or double insulation to
avoid dangerous touch voltages (50 V
AC
and 120 V
DC
) in case of error.
The secondary winding of the transformer shouldn’t be grounded (SELV
supply) (acc. to DIN VDE 0550 or DIN EN 60742).
5. If you want to unplug a power stage from the slot, please note:
Do not unplug the power stage while powered!
Danger of destroying the device!
Up to 3 minutes after turning off the supply voltage, dangerous voltages
may still exist within the device.
6.
Be careful handling the motor connectors at the power stage and any
motor cable coupling.
As long as the power stage is connected to supply voltage, a hazardous
voltage level is present at motor connector and motor cable, even if the motor
is not wired.