Manual MCC-2
MA 1235-A016 EN
32
6.5 X5 Com Communication Interface
The X5 Com communication interface is available as USB, RS 232(4-wire), RS 485, or
Ethernet-connection.
Factory setting:
57 600 Baud
8 Data bits
1 Stop bit
No parity
Protocol::
<STX>
|
Address | Data | Separator | Checksum
| <ETX>
Baud rate
and
Interface parameters
can be modified after installation of MiniLog-Comm
in the menu item
Options/Interface Parameters.
i
If the MCC-2 is connected via Ethernet, the
IP address
•
is created by DHCP
(dynamic IP configuration) or
•
is assigned via Minilog Comm or
phy
LOGIC
®
ToolBox (Interface
parameter/Eth-MCM menu).
i
When the MCC-2 is connected to the PC by USB-interface, USB drivers have to
be installed on the PC.
i
An USB converter is needed, if several controller should be connected by USB.
It is mounted either external or at the first MCC-2 with RS 485 interface.
See chapter 6.5.3 RS 485 interface.