Phytec phyCORE-i.MX 6UL Скачать руководство пользователя страница 4

Application Note 

 

 

 

 

 

4/7

 

 PHYTEC Messtechnik GmbH 2017 

3

 

Production settings 

The Modules have the MSL Level 3, so it is required to store them adequately before soldering 

(see IPC/JEDEC J-STD-033C). I.e. it’s recommended to store the modules shrink-wrapped in the 

original  packing  or  if  the  packing  is  opened  to  store  them  in  a  humidity  reduced  storage  (rel. 

humidity < 10%, T < 30° C / 86° F). The shelf life time in the sealed packaging amounts 12 months 

at < 40° C and < 90 % rel. humidity.  

3.1

 

Paste printing 

For  the  paste  printing  we  recommend  at  least  a  100µ m  stencil  without  pad  reduction.  We  use 

Type 4 paste. 

Fig. 4 Paste printing (orange) without paste reduction, dimensions in mm 

0.8 
 
 

1.55 
 
 

r = 0.36 
 
 

Содержание phyCORE-i.MX 6UL

Страница 1: ...017 M Franck A3 Changed Pin1 marker paste printing 30 06 2017 M Franck A4 Paste reduction removed 24 08 2017 M Franck A5 Link to dimensioned drawings added 15 09 2017 M Franck A6 Introduction changed...

Страница 2: ...the phyCORE i MX6UL modules For a good soldering result we recommend to use the same or nearly the same parameters Fig 1 Top Bottom and Side View Do to of its weight and to reduce the soldering cycles...

Страница 3: ...GmbH 2017 3 7 2 Delivery Format The modules are shipped in 56mm tapes with a feed of 48mm outer reel diameter 33cm 175 pieces are on a reel and 10 empty slots are empty for mounting on a tape feeder F...

Страница 4: ...rink wrapped in the original packing or if the packing is opened to store them in a humidity reduced storage rel humidity 10 T 30 C 86 F The shelf life time in the sealed packaging amounts 12 months a...

Страница 5: ...heck the fiducials on the bottom of the SOM Pin 1 marked with 3 instead of 4 fiducials see Fig 1 The nozzle has to be able to pick up at least 6 grams we pick the SOM with a Samsung CP45 TN110 nozzle...

Страница 6: ...ering profiles for the vapor phase soldering based on J STD 020E Table 5 2 Page 8 The liquidous time amounts 60 to 90 seconds and we recommend maximally 3 soldering processes The peak body temperature...

Страница 7: ...rt if you need additional information or if you have any questions Europe except France France 49 6131 9221 31 33 2 43 29 22 33 support phytec de support phytec fr North America India 1 206 780 9047 o...

Отзывы: