FireWire-CAM-011H/-012H
46
©
PHYTEC Messtechnik GmbH 2006 L-680e_1
The image height H is calculated from the image width B based on
the following relationship:
B
H
⋅
=
4
3
Please note that wide angle lenses will produce some edge
distortion, which can have a detrimental effect during image
capture or analysis. In this case try increasing the distance to the
object and set a larger focal length.
Reference points for selecting focal length:
Focal Length
Lens Type
< 8 mm
Wide Angle
8 ... 16 mm
Normal Range
> 16 mm
Telephoto Lens
A selection of standard lens focal lengths can be found in our
catalog and on our web site. Please ask us about other available
focal lengths.
•
Resolution
How good will the picture resolution be for a given focal length?
This depends on the picture size (size of the screen window) and
the number of pixels the sensor has.
Die FireWire-CAM-x11H / -x12H have a pixel count of
1024 x 768 pixels (H x V).
You can now begin to determine the special resolution by dividing
the picture width in mm by the number of horizontal pixels (1024)
(corresponding vertically).
Example:
You have a screen window that is 100 mm x 75 mm.
The maximum resolution that can be achieved is
100 mm : 1024 = 0.09765 mm horizontal resp.
75 mm : 768 = 0.09756 mm vertical
Содержание FireWire-CAM-011H
Страница 16: ...FireWire CAM 011H 012H 10 PHYTEC Messtechnik GmbH 2006 L 680e_1 ...
Страница 76: ...FireWire CAM 011H 012H 70 PHYTEC Messtechnik GmbH 2006 L 680e_1 ...
Страница 82: ...FireWire CAM 011H 012H 76 PHYTEC Messtechnik GmbH 2006 L 680e_1 ...
Страница 85: ...Dimensions PHYTEC Messtechnik GmbH 2006 L 680e_1 79 6 Dimensions Figure 52 Dimensions ...
Страница 87: ...Published by PHYTEC Messtechnik GmbH 2006 Ordering No L 680e_1 Printed in Germany ...