Service Manual PhysioFlow Lab1 

  1 / 20

 

Version of Monday, 10 July 2017 

 
 
 
 
 
 
 
 
 
 
 

PHYSIOFLOW® Lab1

 TM

 

 
 
 

Service Manual 

 
 
 

Monday 10 July 2017

 

 
 
 
 

 

 
 

 

First placing on the market: 7

th

 April 1999 

Содержание Lab1

Страница 1: ...730 Folschviller France T l 33 0 3 72 82 50 00 Fax 33 0 1 30 74 46 48 support physioflow com Service Manual PhysioFlow Lab1 1 20 Version of Monday 10 July 2017 PHYSIOFLOW Lab1TM Service Manual Monday...

Страница 2: ...e 4 Measuring Technique Information 6 Warnings 7 Precautions 8 Symbols and Marks 9 2 Overall presentation 10 3 Interfaces 11 Description of the electronic unit 11 Description of cables 12 Description...

Страница 3: ...ng this manual is required to ensure a proper use of the medical device Basic technicians and maintenance staff education associated to reading this manual is required for any intervention on the medi...

Страница 4: ...or the PhysioFlow application it equates to a 1 5m distance around the patient himself or of the surface he is in contact with in any direction Conditions of Use The PhysioFlow Lab1 is a noninvasive h...

Страница 5: ...ulmonary causes of acute dyspnea Optimization of atrioventricular interval for patients with A V sequential cardiac pacemakers Patients with need of determination for intravenous inotropic therapy Pos...

Страница 6: ...differences in thoracic electrical impedance are essentially created by changes of velocity and blood volume in the aorta Unlike other trans thoracic bio impedance systems PhysioFlow System does not r...

Страница 7: ...r in the presence of flammable anesthetics Sensors must be only positioned on the skin and nowhere else Disposal of this product and or its accessories shall be made in accordance with all locally enf...

Страница 8: ...e electromagnetic emissions and reduce the immunity of the device PhysioFlow devices must not be sterilized FOR ACCURATE MEASUREMENTS IT IS ESSENTIAL THAT THE OPERATOR UNDERSTANDS THE DIFFERENCE BETWE...

Страница 9: ...on that an error has been detected If the LED is on please contact PhysioFlow support platform support physioflow com In the manual this symbol indicates that one or several conditions could damage th...

Страница 10: ...cted to a PC compatible computer through a RS 232 C serial link It is based on the principles of impedance cardiography The electronic unit performs impedance signal generation reception of chest impe...

Страница 11: ...de Petit Ebersviller 57730 Folschviller France T l 33 0 3 72 82 50 00 Fax 33 0 1 30 74 46 48 support physioflow com Service Manual PhysioFlow Lab1 11 20 Version of Monday 10 July 2017 3 Interfaces Des...

Страница 12: ...rvice Manual PhysioFlow Lab1 12 20 Version of Monday 10 July 2017 Description of cables A Electrical RS 232 serial link cable to be used with a laptop computer only Type zero modem with SUB D9 Male Fe...

Страница 13: ...u stade Petit Ebersviller 57730 Folschviller France T l 33 0 3 72 82 50 00 Fax 33 0 1 30 74 46 48 support physioflow com Service Manual PhysioFlow Lab1 13 20 Version of Monday 10 July 2017 Description...

Страница 14: ...physioflow com or your local dealer No ECG and no impedance signal are displayed verify that the patient cable is connected on PhysioFlow and that the serial connection is OK Replace electric RS 232...

Страница 15: ...completed on the computer The external data acquisition system has to be calibrated adjustment of scales to reproduce measurements displayed on the PhysioFlow Computer screen To perform this task sta...

Страница 16: ...flow com With special authorisation of the manufacturer or the dealer the unit s embedded processor software can be upgraded To perform this operation it is necessary to replace the EPROM First stage...

Страница 17: ...ly 2017 Storage and cleaning Out of operation periods the PhysioFlow unit must be stored at ambient temperature between 40 C and 70 C humidity included between 10 and 100 and an atmospheric pressure i...

Страница 18: ...ndix A Legislation Computer must comply with regulations concerning medical devices Desktop computer or laptop with leakage current under 0 1 mA Please refer to the manufacturer information Please con...

Страница 19: ...ctors Back panel Female SUB D9 serial link to PC Switcher filter fuses module Schaffner Front panel Specific patient connector 6 leads ground Gilded contacts Measurement current Intensity of 3 6 mA pe...

Страница 20: ...ation 15 seconds averaging patient at rest Parameter Unit Low value High Value Variability Heart rate HR bpm 30 215 1 Stroke Volume SV mL 0 220 5 Stroke Volume Index SVi mL m 0 100 5 Cardiac Output CO...