14
5.
Statistics (2nd menu item)
After each measurement Pocket-Surfix® stores the readings in a data memory and calculates a variety of statistic
parameters. Pocket-Surfix® stores up 80 readings in its data memory.
The statistical values are updated after each measurement and stored together with the thickness values. The display
shows the number of measurements N, the mean value x¯ , the standard deviation s, the maximum value Max of the
series and the minimum value Min .
Parameter
Statistics
N
Number of readings
x¯
Mean value
St.Dev.
Standard deviation
Max
Maximum value of the series
Min
Minimum value of the series
All readings and statistics can be completely transferred or displayed at the menu item
Statistics
.
5.1.
Transfer of statistic values only
The gauge calculates five statistical values from a measurement series (see table above). These can be quickly and
simply transferred to a PC in the 2nd menu item
Statistics
.
Transfer can be made immediately after the measurement. Data transfer to a PC can be done by means of the infra-
red interface at the top of the gauge. Use PHYNIX infra-red adapter (art.no. 10641) for the connection. The data