3
2
1
4
B
C
3
2
1
5
WARNING:
Please carefully read and properyly follow the instructions for installation found in this manual.
STEPS:
Valve is stamped with
“HOT” and “COLD” on the
top of the “C” and “F” on bottom.
Valve is designed with two
outlets, but are not intended
to be used simultaneously.
Determine which outlet
will be used and plug
the other with
3/4” plug provided.
1
Hot
Inlet
B
A
Outlet
Cold
Inlet
2
1-3/8” min
2-3/8” max
Finished
Wall
1-3/8” min
1
1
3
2
6
1
2
7
1
2
8
Turn on water supply and open integral stops to
flush lines. Turn off integral stops.
Note:
Make sure black alignment marks on
cartridge line up with marks on stem and are on
top of the cartridge.
Open integral stops to flush lines to volume
control. Turn off integral stops. Replace Plaster
tile guide B.
Close integral stops and remove cartridge.
Install crossbeam and secure with hardware
(not included).
Note:
Connect port to a volume control valve
(purchased separately).
Connect hot and cold using 1/2” copper adapters
and lines.
Note:
Supply lines not included. DO NOT apply
heat directly to valve bodies.
Note:
If valve is installed upside down, a reverse
cartridge is available but will cut flow up to 66%
.