26
Heater Operation
Starting The Heater
Note:
It is important to understand that this heater does not simply turn on and turn off. Rather, it has a
sophisticated operating system similar to a household furnace to provide reliable heating comfort. The
operator should familiarize themselves with the normal operation of the heater.
Start Up
1. Systems Check Phase
• When switched on, the heater conducts a self check.
• Component integrity (Glow Pin, Blower, Fuel Pump, Flame and Overheat Sensor)
• Voltage (Must be with 10.5-16 volts)
• Upon satisfactory systems check, the heater will continue to the Preheat Phase.
2. Preheat Phase – Glow pin will switch on to preheat for 50 seconds.
3. Ignition Phase – Fuel and combustion air are slowly introduced to the combustion chamber and flame is
established typically within 2-3 seconds.
4. Stabilization Phase – To further establish combustion, the glow pin remains on and the fuel / air mixture
is slowly increased. The flame sensor monitors the increasing temperature at the heat exchanger
(Typically 2 ½ minutes).
5. Running Phase – Once the flame is established, the glow pin will switch off. Incoming fuel / air will be
ignited by the established flame inside the combustion chamber.
Running Mode
The heater is designed to function in two different operating modes. Refer to the Operating Switch
Instructions for details.
“Power Mode”
Controls the heat output level.
The operator can adjust heat output level in a range from 1.4 -5.0 in 0.1 intervals.
“Automatic Mode”
Establishes target cabin temperature for heater to maintain.
(Primary operating mode for cargo and cabin heating applications)
Target temperatures range is 10º C to 35º C (1º intervals)
Note:
Internal temperature sensor inside heater is used to regulate the cabin temperature.
Temperature displayed on switch, only reflects temperature at operating switch.
We recommend the use of return ducting (ducting on both ends of heater) for best temperature
regulation
Содержание PH41A
Страница 11: ...11 Heater Mounting Figure M3 Combustion air Seal Exhaust Fuel Line Wiring Harness Heater Flange...
Страница 12: ...12 Heater Mounting Figure M4 2 1 8 3 x 2 4 x 5 Rectangle...
Страница 33: ...33 Heater Components 1 2 3 4 5 6 7 8...
Страница 35: ...35...
Страница 36: ...DKSI com help dksi com 877 508 3900 PHP 072022 TM41A REV5 Vancouver Toronto Dallas...