background image

For Your Safety 

To prevent damage to your product or 
injury to yourself or to others, read the follow-
ing safety precautions in their entirety before 
using  this  equipment.    Keep  these  safety  in-
structions where all those who use this equip-
ment will read them.

The consequences that could result from 

failure to observe the precautions listed in this 
section are indicated by the following symbol:

This icon marks warnings, information that 
should  be  read  before  using  this  Phottix
product to prevent possible injury.

 Do not disassemble or modify

Failure to observe this precaution could result in 
electric  shock  or  product  malfunction.    Should 
the product break open as the result of a fall or 
other accident, remove the batteries and take the 

product to a Phottix-authorized service representa-
tive for inspection.

 Keep dry

Do not handle with wet hands or immerse in or 
expose  to  water  or  rain.    Failure  to  observe  this 
precaution could result in fi re or electric shock.

 

Failure to observe this precaution could result in 
explosion or fi re.

 Keep out of reach of children

This device contains small parts which may pose a 
choking hazard.  Consult a physician immediately 
if a child swallows any part of this device.

 Tu

  immediately in the event of malfunction

Should  you  notice  smoke  or  an  unusual  smell 
coming from this device, remove the battery im-

mediately and take the device to a Phottix-autho-
rized service representative for inspection, taking 
care to avoid burns.  Continued operation could 
result in injury.

 Do not expose to high temperatures

Do not leave the device in a closed vehicle under 
the sun or in other areas subject to extremely high 
temperatures.  Failure to observe this precaution 
could result in fi re or in damage to the casing or 
internal parts.

 Observe precaution when handling batteries

Batteries may leak or explode if improperly han-
dled.    Observe  the  following  precautions  when 
handling batteries for use in this device:

  Use only batteries listed in this manual.  Do not 

mix old and new batteries or batteries of differ-

 

ent types.

  Read  and  follow  all  warnings  and  instructions 

provided by the manufacturer.

  Do not short or disassemble.

  Do not expose to fl ame or excessive heat.

  Do not attempt to insert batteries upside down 

or backwards.

  Batteries  are  prone  to  leakage  when  fully  dis-

charged.  To avoid damage to the product, be 
sure to remove the batteries when leaving the 
product  unattended  for  prolonged  periods  or 
when no charge remains.

  Should liquid from the batteries come into con-

tact  with  skin  or  clothing,  rinse  immediately 
with fresh water.

Notice for Customers in the U.S.A.: Federal Communications 

Commission (FCC) Radio Frequency Interference Statement

This equipment has been tested and found to com-
ply with the limits for a Class B digital device, pursuant 
to Part 15 of the FCC rules.  These limits are designed 
to provide reasonable protection against harmful in-
terference in a residential installation.  This equipment 
generates, uses, and can radiate radio frequency en-
ergy and, if not installed and used in accordance with 
the instructions, may cause harmful interference to 
radio communications.  However, there is no guar-
antee that interference will not occur in a particular 
installation.  If this equipment does cause harmful in-
terference to radio or television reception, which can 
be determined by turning the equipment off  and on, 
the user is encouraged to try to correct the interfer-
ence by one or more of the following measures:

  Reorient or relocate the receiving antenna.

  Increase the separation between the equipment 

and receiver.

  Connect the equipment into an outlet on a cir-

cuit diff erent from that to which the receiver is 
connected.

  Consult the dealer or an experienced radio/tele-

vision technician for help.

CAUTIONS

: The FCC requires the user to be noti-

fi  ed that any changes or modifi cations made to 

this  device  that  are  not  expressly  approved  by 

Nik on Corporation may void the user’s authority 
to  operate the equipment.

Interface  Cables

:  Use  the  interface  cables  sold  or 

provided by Phottix for your equipment.  Using 
other  interface  cables  may  exceed  the  limits  of 
Class B Part 15 of the FCC rules.

For Your Safety 

 

 

TR-90

 e

h

f

s

t

r

a

P

Refer to the illustrations above.

Body

 Connector 
 Cord
 Release lamp 
 Control panel 

 

TIMER START/STOP

 button 

 

SET

 button 

 Illuminator/lock button
 Arrow button

 Shutter-release button 
 Battery-chamber cover 
 Eyelet  for  strap  (available  separately;  use 

cell phone or other similar strap)

Control Panel

 *

 Selection cursor 
 Timer display 
 Lock indicator 
 Low battery indicator 
 “

TIMER ACTIVE

” indicator

 Speaker on/off  indicator 
 “

SET

” indicator

 “

RELEASE

” indicator

 Number of shots

* The illustration inside the front cover shows 

the control panel with all elements lit.  In the 
other  illustrations  throughout  this  manual, 
elements relevant to the explanation in the 
accompanying text are shown in black.  Indi-
cators not mentioned in the text are shown 
in gray.

Parts of the TR-90

Inserting Batteries

Slide the battery-chamber cover ( ) from the 
back  of  the  TR-90  and  insert  two  AAA  1.5 V 
LR03  alkaline  batteries  (available  separately) 
as shown.

 The Low Battery Indicator (

)

The low battery indicator ( ) will blink when the 
batteries are low.  Ready spare batteries.

Replacing Batteries

When replacing batteries:

1

 Check  that  the  “

TIMER  ACTIVE

”  ( )  and  “

LEASE

”  ( )  indicators  are  not  displayed  (see 

right).

2

 Turn the camera off  and disconnect the TR-90.

3

 Remove the batteries.

4

 Wait until the control panel has gone out and 

insert new batteries.

When the TR-90 Is Not in Use

The TR-90 is not equipped with an off  

  .

h

c

ti

w

s

To reduce the drain on the batteries when the 
TR-90 is not in use, end shooting and check 
that the “

TIMER ACTIVE

” ( ), “

SET

” ( ), and “

LEASE

”  ( )  indicators  are  not  displayed  (see 

right).    The  drain  on  the  batteries  increases 
when these indicators are fl ashing.

The Illuminator/Lock Button

Press the illuminator/lock button ( ) briefl y to 
activate the control panel backlight.  The back-
light will remain lit for about six seconds; press-
ing the arrow button ( ) while the backlight is 
on extends the timer for another six seconds.

To lock all controls except the shutter-re-

lease  ( )  and  illuminator/lock  buttons,  press 
the illuminator lock button until the lock icon 
( ) is displayed in the control panel.  To release 
the lock, press the illuminator/lock button until 
the lock icon is no longer displayed.

Parts of the TR-90

Connecting the TR-90

1

 Turn the camera off .

2

 Check  that  the  “

TIMER  ACTIVE

”  ( )  and  “

LEASE

” ( ) indicators are not displayed.

3

 Remove the 10-pin terminal cover from the 

camera.    Keeping  the  mark  on  the  10-pin 
connector ( ) aligned with the mark on the 
camera body, insert the connector as shown 
and then tighten the locking nut.

 Disconnecting theTR-90

After checking that the “

TIMER ACTIVE

” ( ) and “

LEASE

” ( ) indicators are not displayed, turn the 

camera  off   and  disconnect  the  TR-90.    Replace 
the 10-pin terminal cover.

The “TIMER ACTIVE,” “SET,” and “RELEASE” Indicators

 

TIMER ACTIVE

Timer active; press 

ER START/STOP

 button ( ).

SET

Settings  can  be  modifi ed  (page 
8); press 

SET

 button ( ).

RELEASE 

(

TIMER 

ACTIVE

 not 

fl ashing)

Manual  release  active  (page  15); 
release  shutter-release  button 
( ; if button is in 

HOLD

 position, 

release shutter-release lock).

Using the TR-90

The TR-90 functions as:

• 

An automatic timer

 Choose the delay

(time  before  shooting  starts),  exposure 
time, interval, and number of shots for timed 
interval photography.  Shutter speed can be 
selected with the camera if desired.

• 

A manual release

  Take  photographs 

manually using the shutter-release button on 
the TR-90.  Photographs can be taken manu-
ally even when the timer is running.

Timed Photography 

1. Adjust Camera Settings

1.1

 Connect the TR-90 and turn the 

camera on.

1.2

 Adjust camera settings as follows (see the 

camera manual for details):

Exposure mode M

 (manual)

Shutter speed

Bulb

Interval timer

Off 

Focus 

 (continuous-servo autofo-

cus)

 *

 or 

M

 (manual)

Continuous

S

 (single frame)

* Select “release priority” if available.

2. Set the Timer

2.1

 Press the 

SET

 button ( ).  “

SET

” will fl ash in 

the control panel.

The TR-90 can be connected to the camera

after the timer has been set.

2.2

 Adjust the following settings:

O

s

g

n

it

t

e

d

e

t

r

o

p

p

u

S

n

o

it

p

ir

c

s

e

D

n

o

it

p

DELAY

Delay before shutter is released

0 s to 99 hrs 59 min 59 s (in one-second increments)

LONG

Exposure time

INTVL

Inter

)

s

t

n

e

m

e

r

c

n

d

n

o

c

e

s

-

e

n

o

 

n

i(

 s

 

9

5

 

n

i

m

 

9

5

 s

r

h

 

9

9

 

o

1

l

a

v

N

Number of shots

1 to 399,   (unlimited)

Speaker on/off 

 (on),   (off )

Delay, Exposure, and Interval Settings

Shutter closes

Shutter closes

Shutter opens

Shutter opens

Delay

Exposure 

time

Exposure 

time

Interval

Number of shots (

N

)

Number of shots (

N

)

e

m

a

r

d

n

2

e

m

a

r

t

s

1

e

m

a

r

t

s

1

2nd frame

n

th frame

n

th frame

Timer starts

Timer ends

Timed Photography 

Timed Photography

Eng

Timed Photography 

Timed Photography 

 Setting the Timer

To ensure correct operation, choose an interval at 
least one second longer than the exposure time.  
When using autofocus, set the delay to two sec-
onds or more and choose an interval at least two 
seconds longer than the exposure time to ensure 
that the camera has time to focus.  When using 
long  exposure  noise  reduction  (available  with 
some  digital  cameras),  the  interval  should  be  at 
least twice the exposure time.

Intervals of 00:00:00 will automatically be re-

set to 00:00:01 when the 

SET

 button ( ) is pressed 

to put settings into eff ect.

To set the number of shots to   (unlimited), 

select 

1

 and press the arrow button ( ) down or 

select 

399

 and press the arrow button up.

2.3

 After adjusting all settings as desired, press 

the 

SET

 button ( ) to put the new settings 

into eff ect.  A beep will sound (if the speak-
er is on) and the “

SET

” indicator will go out.

The new settings will remain in eff ect until 
changed or until the batteries are removed 
or exhausted.

3. Start the Timer

Press  the 

TIMER  START/STOP

  button  ( ).    The 

timer will start and “

TIMER ACTIVE

” ( ) will fl ash 

in the control panel.  Between shots, the con-
trol panel will show the time remaining until 
the next photograph is taken.  If the speaker is 
on, a beep will sound three times at one-sec-
ond intervals before the shutter opens.

While  the  shutter  is  open,  the  control 

panel will show the time remaining until the 
shutter  closes,  and  the  release  lamp  and “

LEASE

”  indicator  ( )  will  fl ash  at  one-second 

intervals.  The number of shots remaining will 
be updated each time a photograph is taken.

Control Panel Display (Timer Active)

Timed Photography

Flashes while timer is active

Between shots

: Time remaining 

until next shot

While shutter is open

: Time remain-

ing until shutter closes
Number of shots remaining
Flashes while shutter is open

The Speaker and Release Lamp

The following illustration shows when a beep will sound ( ) and the release lamp fl ash ( ) with a delay 
of 5 s, an exposure time of 4 s, and an interval of 9 s.

Shutter closed

Shutter closed

Shutter open

Shutter open

(s)

Timer starts

5

1

2

3

4

6

7

8

9

10

5

2

6

1

5

1

4

1

3

1

2

1

1

1

17

18

19

20

21

22

23

24

4. End Shooting

Shooting will end automatically when the se-
lected number of shots has been taken.  To end 
shooting  before  all  photographs  have  been 
taken, press the 

TIMER START/STOP

 button ( ).

Using the Camera to Select Shutter Speed

To take photographs at the shutter speed selected with the camera, adjust settings as follows:

Camera

Exposure mode M

 (manual) or 

S

 (shutter-priority auto)

Shutter speed

Any

Interval timer

Off 

Focus mode

 (continuous-servo autofocus)

 *

 or 

M

 (manual)

Shooting mode S

 (single frame)

MC-36

Exposure time

0 s

Interval

Longer than camera shutter speed

 †

* Select “release priority” if available.
†When using autofocus, choose an interval at least two seconds longer than the camera shutter speed 

to allow the camera time to focus.  When using long exposure noise reduction (available with some 
digital cameras), choose an interval at least double the camera shutter speed.

 Using the Timer

Before  using  the  timer  for  extended  periods, 
check that the batteries have enough charge.  Re-
place the batteries when the low battery indicator 
(

) fl ashes in the control panel ( ).

Timed Photography

Manual Release

The  TR-90  shutter-release  button  (

)  func-

tions  in  much  the  same  way  as  the  camera 
shutter-release button.

1. Adjust Camera Settings

  Connect  the  TR-90  and  turn  the 

camera on.  Choose exposure mode, shut-
ter speed, focus mode, and shooting mode 
as desired.

2. Take Pictures

2.1

 Press the TR-90 shutter-release button (

halfway  and  check  focus  and  exposure, 
then  press  it  the  rest  of  the  way  down  to 
take  a  picture.   While  the  shutter  is  open, 
a beep will sound at one-second intervals, 
the “

RELEASE

“  indicator  ( )  will  fl ash,  and 

the  control  panel  will  show  the  time  re-
maining until the shutter closes.

To keep the shutter-release button ful-

ly pressed for bulb photography, slide the 
button to the 

HOLD

 position.  Slide it in the 

opposite direction to release the lock.

2.2

 Release the button to end shooting.

The TR-90 shutter-release button can be used 
when no batteries are inserted.  The control pan-
el will remain off  and no beep will sound.

The  shutter-release  button  can  be  used  to  re-
lease the shutter manually while the timer is ac-
tive.  Timer count-down (including the control-
panel  display,  release  lamp,  and  beep)  contin-
ues during manual release.  If a manual release 
overlaps with an automatic release, the shutter 
will remain open until both exposure times have 
expired.

Precautions for Use

Check  the  camera  battery  level  and  number 
of exposures remaining before using the TR-
90  (see  the  camera  manual  for  details).   The 
timer will continue to operate even when no 
pictures can be recorded due to low battery, 
lack or fi lm or memory, or lack of space in the 
memory buff er (digital cameras only).  An AC 
adapter (available separately) is recommended 
for longer sessions.

Some  cameras  have  an  AF  activation 

option  that  determines  whether  the  camera 
will  focus  when  the  shutter-release  button  is 
pressed  halfway  (see  the  camera  manual  for 
details).  Enable shutter-release button AF-ac-
tivation when using the TR-90.

Please note that the timer is less accurate 

than most watches or household clocks.

Caring for the TR-90

Do not drop

: The product may malfunction if sub-

jected to strong shocks or vibration.

Keep dry

: This product is not waterproof and may 

malfunction if immersed in water or exposed to 
high  levels  of  humidity.    Rusting  of  the  internal 
mechanism can cause irreparable damage.

Avoid sudden changes in tem per a ture

: Sud den chang-

 

 r

o

 

g

n

i r

e

n

e

 

n

e

h

w

 r

u

c

o

 s

a

 

h

c

u

,

e

r

u

r

e

m

e

n

s

e

 

e

s

u

a

c

 

n

a

c

 ,

y

a

d

 

d

l

o

c

 

a

 

n

o

 

g

n

d

li

u

b

 

d

t

a

e

h

 

a

 

g

n

v

a

e

l

-

n

o

c

 t

n

e

v

e

r

p

 

o

T

  

.

e

c

i

e

d

 

e

h

e

d

is 

n

n

o

it 

a

n

e

n

o

c
 

 

a

 r

o

 

e

s

a

c

 

g

n

y

r

a

c

 

a

 

n

e

c

i

v

e

d

 

e

h

e

c

a

l

p

 ,

n

o

it 

a

n

e

d

 s

g

n

a

h

c

 

n

e

d

u

s

 

o

ti

 

g

n

i s

o

x

e

 

e

r

o

e

b

 

g

a

b

 

c

it 

s

a

l

p

.

e

r

u

r

e

m

e

n

i

:  Strong  static 

 

d

e

c

u

o

r

p

 s

d

l

e

 fi

 

c

i t

e

g

a

m

o

r

t

c

e

l

e

 

e

h

t

 r

o

 s

g

r

a

h

c

 

d

l

u

o

c

 s

r

e

ti

m

 s

n

a

r

t

 

o

i

d

a

r

 s

a

 

h

c

u

s

 t

n

e

m

 

p

i

u

q

e

 

y

b

.

e

c

i

v

e

d

 

e

h

h

ti

w

 

e

r

e

f r

e

n

i

A note on electronically-controlled devices

: In extreme-

 r

a

e

p

a

 

y

a

m

 s

r

e

c

r

a

h

c

 l

u

s

n

u

 ,

s

c

n

a

t

n

e

r

a

r

 

y

l
in  the  control  panel  and  the  device  may  stop 
func tion ing.  In most cas es, this phe nom e non is 

 

n

r

u

T

  

.

e

g

r

a

h

c

 

c

i t

a

t

s

 l

a

r

e

x

e

 

g

n

o

r

t

s

 

a

 

y

b

 

d

e

s

u

a

c
the  camera  off ,  disconnect  the  TR-90,  remove 
the  batteries,  and  then  replace  them  once  the 
control panel has turned off .  Caution is required 
when handling the batteries, which may be hot 

 ,

n

o

it 

c

n

u

f l

a

m

 

d

e

n

it 

n

o

c

 f

o

 t

n

e

v

e

 

e

h

n

 .

e

s

u

 

m

o

rf

.

e

v

it 

a

n

e

e

p

e

n

o

k

i

N

 r

o

 r

li

a

e

r

u

o

y

 t

c

a

n

o

c

The control panel

:  LCD  displays  tend  to  darken  at 

high  temperatures  and  exhibit  slower  response 
times at low temperatures.  This does not indicate 
a malfunction.

Supported cameras

 *

Nik

on, Canon, Sony, Olympus, Pentax, Samsung, Kodak, Fuji, Minolta

Timer delay

0 s to 99 hrs 59 min 59 s in one-second increments

Exposure time

0 s to 99 hrs 59 min 59 s in one-second increments

Interval

1 s to 99 hrs 59 min 59 s in one-second increments

Number of shots

1 to 399,   (unlimited)

Power source

Two AAA 1.5 V LR03 alkaline batteries

Battery life

Approximately two months of continuous shooting with a delay of 5 min, an exposure time of 4 min 56 s, and an interval of 
5 min.  Use of the  illuminator will reduce battery life.

Operating temperature

–20 – +50 °C (–4 – +122 °F)

Dimensions

Approximately 155 × 40 × 18 mm (6.1 × 1.6 × 0.7 in.), excluding projections

Weight

Approximately 105 g (3.7 oz), excluding ferrite core

Length of cord

Approximately 850 mm (33.5 in.)

S

Hour

Minute

Second

Minute

Second

Exposure time

Interval

Number of shots

Speaker

Setting the Timer

Use the arrow button to set the timer.  
Press left or right to select, up or down 
to change.  The current selection is in-
dicated by the selection cursor ( ).

Adjust
settings

Setting
complete

Delay (time until shooting starts)

Press 

SET

 ( ) at any time to complete the opera-

tion and display the new settings for the selected 
item.  To view other settings, press the arrow but-
ton left or right.  The current selection is indicated 
by the selection cursor ( ).  Press the 

SET

 button 

to edit the current setting as described above.

Hour

Second

Minute

Hour

TR-90

INSTRUCTION MANUAL

Notices 

C6

C8

N10

N8

N6

S6

O6

Отзывы: