background image

 

 

Us
in

g

 th

e

 S

ys

te

m

 S

a

fe

ly

 a

n

d

 Corre

ctl

y

 

 

 

 

 

 

■Always unplug the system when cleaning it or when it is unused for a long period 

of time. Leaving or storing the system connected to the power source might cause 

fire from insulation deterioration or electrical discharge.

 

 

 

■Please consult us in advance when you perform an event by which laser light or 

direct rays fall on the image sensor surface.

 

 

 

■Do not set the system in a location where the temperature gets unusually hot.

 

The trunk and inside of a car can get especially hot in summer.

 

Doing so can cause the outer case and internal components to deteriorate or cause a 

fire.

 

 

 

■Do not place the system in a location prone to oily smoke or steam, or in a location 

with a lot of humidity or dust.

 

Oil, moisture, and dust conduct electricity, which can cause a fire or electric shock.

 

 

 

■Ambient temperature 0-45°C, humidity 80% RH or lower, maximum altitude 

2,000m or lower. In addition, if exceeding these limits, use in a condensation-free 

environment.

 

Use in a condition out of the above limits can cause malfunction.

 

 

 

■Do not store the equipment in a location where the temperature goes below -20°C 

or higher than 60°C. Also, prevent condensation from forming during shipment.

 

 

 

■When shipping, remove the connecting cable and use the original packaging or a 

dedicated carrying case.

 

Do not ship the equipment in an environment where the temperature goes below -

20°C or higher than 60°C. Also, prevent condensation from forming during 

shipment.

 

 
 

Caution 

Содержание FASTCAM MH6

Страница 1: ...FASTCAM MH6 Hardware Manual...

Страница 2: ...easonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed a...

Страница 3: ...perating instructions and warnings necessary for using the system Before using the system please read the entire manual If any part of this manual is unclear contact Photron using the contact informat...

Страница 4: ...ration and a list of items that should be checked before using the system Chapter 2 Recording This chapter explains operations related to recording Chapter 3 Product Specifications This chapter explai...

Страница 5: ...This symbol indicates the location of a reference This symbol indicates content that should always be read This symbol indicates instructions that should always be followed when using the software or...

Страница 6: ...explained next Please pay careful attention to the content of the safety precautions when using the system This symbol indicates actions that carry the risk that a person could receive a serious injur...

Страница 7: ...short circuit or heat Do not disassemble or modify the system There are high voltages inside the system that can cause electric shock Do not plug in or unplug the power cord with wet hands Doing so ca...

Страница 8: ...system in a location prone to oily smoke or steam or in a location with a lot of humidity or dust Oil moisture and dust conduct electricity which can cause a fire or electric shock Ambient temperature...

Страница 9: ...with a tripod please check the tripod load capacity and be careful not to exceed the load bearing capacity Also when using a tripod please make sure that the tripod tripod screw panhead and others are...

Страница 10: ...r handling of this type of waste could have a possible impact on the environment and human health due to potentially hazardous substances that are generally associated with EEE Your cooperation in the...

Страница 11: ...atic or charged fiber technology Please discharge any electrostatic build up in your body by touching a grounded metallic surface before working near the camera sensor Very gently use only clean and d...

Страница 12: ...YNC Circuit Diagram 14 1 2 7 IO INPUT_IF Circuit Diagram 15 Recording 16 2 1 Selecting Frame Rate Resolution 17 2 2 Selecting Shutter Speed 18 Product Specifications 19 3 1 Specifications 20 3 1 1 Pro...

Страница 13: ...2 PORT Cable 32 Contacting Photron 33 4 1 About the Warranty 34 Contacting Photron 35 5 1 Contact Information 36 A Appendix 37 A 1 Reference Information 38 A 1 1 Relative Spectral Response monochrome...

Страница 14: ...1 Setup This chapter gives an overview of the components that make up the system It also explains a list of items that should be checked before using the system...

Страница 15: ...ries 1 1 2 Accessories Options The following options are available for the system 1 Hi G Bracket for MH6 Main Unit 2 Hi G Cable Fix Handle for MH6 Main Unit 3 Camera Cable for MH6 9m 6m 4 Cable Remova...

Страница 16: ...era head ports When purchasing it is possible to select the Camera head type and the number of heads according to the application or your demands The type categories are listed as follows Camera head...

Страница 17: ...ptional components to shock Do not use in an area where flammable gas or dust is present Do not place in an unstable location such as on an unstable platform or an incline Do not disassemble or modify...

Страница 18: ...Unit Camera Connector USB 3 0 USB 3 0 Connector POWER Power Switch USER USER SW1 4 Status Indicator LED KEYPAD Remote keypad Connector I O PORT 2 I O Port Connector I O PORT 1 I O Port Connector Giga...

Страница 19: ...2 3 CameraHead 1 920x1 400 10 000fps Main Unit Since the camera head is not compatible with hot plug please remove it before turning off the main power Please note that it will cause malfunction if yo...

Страница 20: ...ince the camera head becomes hot be sure to attach the Hi G camera lens bracket or a fixture that can ensure equivalent heat dissipation performance A different Hi G lens Bracket is prepared for each...

Страница 21: ...ra head with Hi G Bracket Below is an example of the procedure for attaching the camera head bracket 2 Use M3 x depth6 hex socket cap bolts to attach to the left and right sides 3 Use M3 depth6 flat h...

Страница 22: ...cap bolt M4 10 hex socket cap bolt M4 10 hex socket cap bolt with M4 washer 6 Use knurled screw and M3 depth4 bind both sides to install the parts Knurled screw M3 4 bind Completion 4 Attach four scre...

Страница 23: ...10 FASTCAM MH6 1 2 Part Names Main Unit with Hi G Bracket Hi G Cable Fix Handle...

Страница 24: ...able 1000BASE T compatible interface board with a LAN cable For the LAN cable prepare a UTP or STP CAT5E enhanced category 5 or higher LAN cable UTP unshielded STP shielded The maximum cable length be...

Страница 25: ...G30 RS485 11 CAM Sup Grey GND 12 CAM Sup Black GND 13 Eth A Orange White Pair 2 Wire 1 14 Eth D Brown White Pair 4 Wire 1 15 Eth C Blue White Pair 1 Wire 1 16 General Out Brown AWG30 Ready Sync out ri...

Страница 26: ...1 2 Part Names Photron recommends using an STP cable over long distances or in noisy locations The system s factory default IP address is below IP ADDRESS 192 168 0 10 NETMASK 255 255 255 0 GATEWAY A...

Страница 27: ...7 k 1 S Y N C _ F _ i S Y N C _ R _ i n T R I G _ D I F F _ i V DD _ 3 3 V 1 0 0 5 1 8 k 1 1 0 0 5 1 8 k 1 1 2 D I 3 G ND 4 Y 5 6 B 7 A 8 1 6 0 8 4 7 k 1 2 N7 0 0 2 E T 1 G D G S D G S B L M 1 8 P G 4...

Страница 28: ...15 FASTCAM MH6 1 2 Part Names 1 2 7 IO INPUT_IF Circuit Diagram...

Страница 29: ...2 Recording This chapter explains operations related to recording...

Страница 30: ...the readout area of the image sensor Restricting resolution enables higher speed recording It also reduces data amount and then it enables longer time shooting recording For the detailed setting refer...

Страница 31: ...is of a shorter period than the frame rate high speed objects can be shot without blur When the frame rate is lower than 1 000 fps the shutter speed can be changed from 1 1 000 1msec and when the fram...

Страница 32: ...4 Product Specifications This chapter explains the system s specifications...

Страница 33: ...GB heads Internal Strage SSD 512GB Trigger Method START CENTER END MANUAL RANDOM RANDOM MANUAL External Synchronization Input Signal I O1 RS485 not termination or 5Vp p Positive Negative polarity swit...

Страница 34: ...m 9m not include 1m direct cable from camera head AC Power Supply Supply Voltage US 120V EU 240V Supply Frequency 50Hz 60Hz Power Consumption 150W DC Power Supply Power Voltage 22V 32V Power Consumpti...

Страница 35: ...920x 280 1920x 224 1376x 1376 1280x 1024 1280x 800 1280x 600 1280x 512 1280x 256 1280 x196 1280 X156 50 500 750 1000 1600 2000 2640 3000 4000 5000 6000 7000 8000 9000 10000 1024 1024 320 240 1024x 102...

Страница 36: ...11 983 23 967 47 934 1 920x224 9 986 14 979 29 959 59 917 1 376x1 376 2 268 3 402 6 805 13 609 1 280x1 024 3 276 4 915 9 830 19 660 1 280x800 4 194 6 291 12 582 25 165 1 280x720 4 660 6 990 13 981 27...

Страница 37: ...cations The number of images that can be recorded varies depending on the connected PORT It is recommended to use the following combination 6 Heads CAM 1 to CAM 6 4 heads CAM 1 to 2 CAM 4 to 5 2 heads...

Страница 38: ...25 FASTCAM MH6 3 2 Dimensions Dimensions 3 2 1 Main Unit mm 117 5 150 70 210 27 5 15 55 7 5 12 20 5 4 M4 6 4 M4 6...

Страница 39: ...26 FASTCAM MH6 3 2 Dimensions 3 2 2 Main Unit with Hi G Brackets mm 50 270 245 2 10 230 161 270 3 2 10 Front View Right Side Vidw...

Страница 40: ...ons 3 2 3 CameraHead mm 3 7 5 25 35 25 5 3 7 35 4 40 4 35 4 4 5 102 1 66 1 18 20 5 4 25 5 1000 5 8 M3 DEPTH2 5 17 77 Image Sensor Position 0 7 Sensor Cover Glass Sensor Position Bottom View Front View...

Страница 41: ...28 FASTCAM MH6 3 2 Dimensions 3 2 1 CameraHead with Hi G Bracket mm 6 6 R 8 0 6 6 C O N S T 101 66 97 35 66 5 Top View Left Side View...

Страница 42: ...3 2 1 Hi G Bracket Hi G Bracket Side A mm 0 8 R21 5 25 40 9 5 39 5 42 3 24 6 30 2 3 4 59 5 55 5 50 2 3 4 32 2 R 2 3 2 5 2 7 5 32 5 31 4 5 4 5 31 2 M3 Depth3 Diameter of drilling4 4 M4 Through tap 2 M3...

Страница 43: ...5 20 6 27 4 16 5 R30 2 R 3 4 5 2 5 4 5 25 3 5 9 4 6 Constant 2 M3 depth6 through tap8 5 Hi G Bracket Bottom mm 7 0 5 15 5 21 4 71 76 9 28 4 R 1 33 92 4 6 2 18 5 R 27 06 6 6 4 3 4 20 6 2 R 4 C1 55 4 R8...

Страница 44: ...2 5 3 75 3 50 39 5 4 C 1 Hi G Bracket Front mm 5 7 1 5 4 R 1 3 1 5 27 2 2 R 36 17 26 30 4 2 1 0 1 0 23 25 8 R 1 24 1 6 5 46 40 8 36 4 5 25 10 25 43 0 3 0 4 32 5 4 3 6places 2 M3 through tap M2 6X4 5 S...

Страница 45: ...ASTCAM MH6 3 2 Dimensions 3 2 1 Power Supply Unit mm 3 2 2 I O 2 PORT Cable I O cable TRIG TTL IN GENERAL OUT3 GENERAL OUT2 GENERAL OUT1 GENERAL IN S Y N C I N TRIG TTL OUT TRIG SW IN T R I G I N 400...

Страница 46: ...4 Contacting Photron...

Страница 47: ...lightning other natural disasters pollution or the effects of abnormal voltage Damage or malfunction as a result of dropping or mishandling during shipment or when moving after purchase or misuse Con...

Страница 48: ...5 3 Contacting Photron This chapter lists the contact information to use when contacting Photron if the system malfunctions or if a portion of the manual is unclear...

Страница 49: ...Antipodes PHOTRON USA INC 9520 Padgett Street Suite 110 San Diego CA 92126 4426 USA Phone 800 585 2129 or 858 684 3555 Fax 858 684 3558 E mail image photron com www photron com In Europe Africa and I...

Страница 50: ...A 3 A Appendix...

Страница 51: ...1 1 Relative Spectral Response monochrome The spectrum response curve is a nominal a reference data of the monochrome image sensor device A 1 2 Relative Spectral Response color The spectrum response...

Страница 52: ...rights reserved Printed in Japan Control No J181001U FASTCAM MH6 Hardware Manual Revision 4 00E Publication Date November 2018 Publisher PHOTRON LIMITED 21F Jimbocho Mitsui Bldg 1 105 Kandajimbocho C...