4
Figure 3: Remote control software: control parameters
7)
Setting of Pump-off Threshold: when input power is below the set Pump-off Threshold
the Pump will automatically turn off.
8)
Work Mode Setting
•
ACC mode (constant current control mode): 0~400 mA
•
APC mode (constant power control mode): -8~17dBm
Select desired working mode and input current/power value, then click Setting
Button to apply.
Click Read Button again to view the set value.
5
Trouble Shooting
Alarm
Possible Cause
Solution
Pump current alarm
Internal problem
Contact us for help
Pump temp alarm
Dirty or loose connector,
or low input power
Check input source
Module temp alarm
Internal problem
Contact us for help
High ambient temperature
Ambient temperature needs to
be within the specification
Input alarm
Dirty or loose connector,
or low input power
Check input source
Output alarm
High output
Check input
Internal problem
Contact us for help
Device disabled
Enable device