Installation of the driver is now complete (Fig. 16) 

 

 

In  case  this  driver  installation  is  not  successful  the  driver  may  be  downloaded  directly  from  PSI  websites 
www.psi.cz. 

 

Once the device is properly connected to the computer, the indicating icon appears 
on the SpectraPen device display Fig. 17.  

 

 

Fig. 15 Choose the driver from the USB disc.

 

Fig. 16 Complete installation.

 

Fig.  17  Icon  on  the  SpectraPen  device  display 
indicating the proper USB connection.

 

Содержание SpectraPen SP 110

Страница 1: ......

Страница 2: ...he specifications of the device However deviations cannot be ruled out Therefore a complete correspondence between the manual and the real device cannot be guaranteed The information in this manual is...

Страница 3: ...on 9 5 PC communication 14 5 1 USB connection 14 5 2 Driver installation 14 6 SpectraPen software 17 6 1 Software installation 17 6 2 Software menu 19 6 3 Data transfer and visualization 20 6 4 Online...

Страница 4: ...nstructions in this guide Always follow corresponding manuals while working with the SpetraPen device or doing the maintenance It is forbidden to interfere with the hardware or software of the SpetraP...

Страница 5: ...onitoring of artificial lighting used in horticulture industry or light source testing Spectrum of measured light source is instantly displayed on the SpectraPen touch screen All recorded data are aut...

Страница 6: ...asurements Data transfer USB cable PC software SpectraPen 1 1 Windows 7 and higher Battery type Li Ion rechargeable battery Battery capacity 2600 mAh Max charging current 0 5 A Charging Via USB port P...

Страница 7: ...Page 7 3 DEVICE DESCRIPTION Fig 1 Device description...

Страница 8: ...d the manufacturer immediately The carton and all packing materials should be retained for inspection by the carrier or insurer For customer support please write to support psi cz 3 2 CARE AND MAINTEN...

Страница 9: ...nd charge the battery Main display Fig 2 Get spectrum measure and save the spectrum to the device internal memory Integration time move the slider to set measuring time Measure Fig 3 Scope rough spect...

Страница 10: ...cted from measured data Get Reference check to get reference spectrum without the sample in the optical path A reference needs to be obtained for absorbance or transmittance measurements Data Browse F...

Страница 11: ...the original display o Marker enable enables display of the numeric coordinates of the point touched on the graphical display in the right hand corner o Autoscale enables the auto scale of the y axis...

Страница 12: ...es and adjust it using the arrows LCD Fig 9 is used to adjust LCD display control settings o Backlight intensity move slider to adjust back light intensity in percentage o Backlight time out move slid...

Страница 13: ...r after download o Average Average function is used for adjusting the number of scans for each reading Averaging of more scans results in a higher signal to noise ratio but increases the time required...

Страница 14: ...to pushing them together Once this connection is achieved the cable may be secured in position by turning the metal cover of the cable and locking the cable in position To connect SpetraPen with your...

Страница 15: ...PSI USB Device appears in the list Right click on it and select Update Driver Software Fig 14 Click Browse my computer for driver software and select Driver folder on the SpectraPen installation disk...

Страница 16: ...downloaded directly from PSI websites www psi cz Once the device is properly connected to the computer the indicating icon appears on the SpectraPen device display Fig 17 Fig 15 Choose the driver fro...

Страница 17: ...number for the SpectraPen may be found in the file SN txt which is included on the enclosed USB flash disk Please Note it is not possible to download data from the SpectraPen device without software r...

Страница 18: ...Page 18 Fig 20 SpectraPen connected Fig 21 SpectraPen not connected...

Страница 19: ...d to download data from the GPS module of the old version of the SpectraPen SP 100 Memory Erase Erases data from the SpectraPen memory Online Control Online control of SP device For more information o...

Страница 20: ...data are store and displayed listed with the time stamp of measurement Please note that if there are no data stored in the memory the download function is not active 5 Visualization modes Scope mode...

Страница 21: ...p right corner of the graph green rectangle is displayed exact value for the selected point on the x axis and y axis 9 To zoom in on the data displayed in the graph select an area of the displayed gra...

Страница 22: ...26 in green rectangle Please note that SP 110 does not have default predefined calculations from the manufacturer The user can create formulas based on own requirements For more information please see...

Страница 23: ...lized to dark spectrum scan are exported for all acquired scans or set of selected measurements Spectrum Transmittance transmittance data for all measurements are exported Spectrum Absorbance absorban...

Страница 24: ...th three dots next to Get button in the window of the software Here the time interval of the measurement is set To apply this setting use the option Use settings and confirm by clicking OK The measure...

Страница 25: ...for appropriate version of the firmware for your particular device Incompatible firmware version can cause device malfunction 1 Starting Update Select Setup Update Firmware From File 2 Selecting bxn...

Страница 26: ...nd time zone must correspond to GPS time time zone in your location 7 1 GPS SPECTRAPEN OPERATION 1 Check the time setting on the SpectraPen device Settings Date Time 2 Switch the GPS module ON on the...

Страница 27: ...nts 4 Connect the SpectraPen to the computer and open the SpectraPen software to proceed with download of the measured data Data measured with activated GPS module are downloaded with GPS coordinates...

Страница 28: ...ses associated with the repair or installation of replacement parts at the customer s site The manufacturer repairs or replaces faulty instruments as quickly as possible the maximum time is one month...

Страница 29: ...PSIindex PSI test index Scope 600nm Scope 500nm Scope the index is placed in the bookmark Scope in data in the software PSIindex name of the index in the SpectraPen software and in exported data PSI...

Страница 30: ...ction only one value can be function min array array array of numbers example1 max Scope example2 min Irradiance example3 min Scope 760nm max Scope 450 Scope 680 example4 max Irradiance 550nm 5 4 4 __...

Страница 31: ...example1 sqrt 5 example2 sqrt Scope 760nm example3 sqrt max Scope 550nm Scope 480nm example4 sqrt 5 4 4 6 ____________________________________________________________________________ specified number...

Страница 32: ...Page 32 example1 integral IrradianceL 360nm 700nm example2 integral IrradianceE 360nm 700nm IrradianceE 450...

Отзывы: