6 Encoder
A
B
G r a y C o u n t e r
H i g h R e s o l u t i o n C o u n t e r
0
1
2
3
0
1
2
3
2
1
0
3
2
1
2
3
0
0
1
2
3
4
5
6
7
6
5
4
3
2
1
2
3
4
1
5
F o u r P h a s e C o u n t e r
0
1
0
1
Figure 6.2: Encoder Modes
6.2
Encoder trigger output
The trigger output of the encoder reacts to changes of the position counter. Triggers are
generated according to the EncoderOutputMode property:
Off
Disables the encoder output trigger.
PositionUp
Triggers are generated whenever the position counter increments and the position
value has not previously been reached.
PositionDown
Triggers are generated whenever the position counter decrements and the
position value has not previously been reached.
DirectionUp
Triggers are generated whenever the position counter increments.
DirectionDown
Triggers are generated whenever the position counter decrements.
Motion
Triggers are generated whenever the position counter value changes.
In order to keep track of the highest respectively lowest position in the PostionUp and -Down
modes, a watermark counter is used. The counter resets whenever the output mode changes,
the encoder is reset or a new start value is written. See Fig. 6.3 for a comparison of the modes.
The number of generated output triggers can be reduced by setting the EncoderDivider
H
i g h R e s o l u t i o n M o d e
A
B
G r a y C o u n t e r
E n c o d e r C o u n t e r
P o s i t i o n U p T r i g g e r
P o s i t i o n U p W
a t e r m a r k
0
1
0
1
2
0
1
3
0
1
2
3
0
1
2
2
3
3
4
4
5
5
0
3
2
1
0
1
2
3
0
1
2
3
0
1
6
6
7
7
8
8
9
9
8
7
6
5
4
5
2
6
7
8
9
1 0
1 1
1 2
1 3
1 4
1 0
1 1
1 2
1 3
1 4
P o s i t i o n D o w n T r i g g e r
D i r e c t i o n U p T r i g g e r
D i r e c t i o n D o w n T r i g g e r
M o t i o n T r i g g e r
P o s i t i o n D o w n W
a t e r m a r k
0
Figure 6.3: Encoder Output Modes
property accordingly. This property only affects the trigger output, the position is tracked
exactly the same independent of the divider value.
6.3
Encoder Status
The encoder has different states which reflect on the A/B input signals. The current state can
be read out by the EncoderStatus register. The following list shows the available states:
52 of 139
MAN094 03/2021 V1.0
Содержание MV8-D8424-G01-GT
Страница 8: ...CONTENTS 8 of 139 MAN094 03 2021 V1 0...
Страница 12: ...1 Preface 12 of 139 MAN094 03 2021 V1 0...
Страница 16: ...3 Product Specification Figure 3 1 Photonfocus MV8 Gpixel 10 GigE camera series 16 of 139 MAN094 03 2021 V1 0...
Страница 40: ...4 Image Acquisition 40 of 139 MAN094 03 2021 V1 0...
Страница 50: ...5 Counter Timer 50 of 139 MAN094 03 2021 V1 0...
Страница 68: ...10 Frame Rate 68 of 139 MAN094 03 2021 V1 0...
Страница 79: ...11 6 Binning MAN094 03 2021 V1 0 79 of 139...
Страница 92: ...12 Precautions 92 of 139 MAN094 03 2021 V1 0...
Страница 110: ...13 Hardware Interface 110 of 139 MAN094 03 2021 V1 0...
Страница 116: ...15 Troubleshooting 116 of 139 MAN094 03 2021 V1 0...
Страница 122: ...18 Support and Repair 122 of 139 MAN094 03 2021 V1 0...
Страница 124: ...19 References 124 of 139 MAN094 03 2021 V1 0...
Страница 128: ...A Pinouts 128 of 139 MAN094 03 2021 V1 0...
Страница 138: ...C Use Cases 138 of 139 MAN094 03 2021 V1 0...
Страница 139: ...D Document Revision History Revision Date Changes 1 0 March 2021 First Version MAN094 03 2021 V1 0 139 of 139...