Timed Exposure Mode Camera Timing
Fig. B.1 shows a timing example, when the camera capture frames with rising edges on the
camera ISO_IN input. The external signal, which is fed into the cameras ISO_IN input is isolated
by an opto-isolator. This signal is delayed by t
iso
−
in
before it reaches the FPGA input "Line In".
The "Line In" signal is synchronized to the FPGA clock domain and the rising edge is detected.
There is a clock uncertainty because of the synchronization logic which is shown by the
t
input
−
jitter
value. The input pulse can be delayed by the trigger delay feature (see Section 4.6.6)
according to the requirement of the application. Finally the exposure time cycle starts after an
offset delay t
exposure
−
offset
.
When the application needs a strobe pulse together with the image acquisition, the internal
line in pulse can also be used to start one of the timer. After the timer delay t
timer
−
delay
the
timer duration t
timer
−
duraton
is started which is shown by the timer active signal (see Section
6.2). The timer active signal needs to be selected to output it on "Line Out" (see Section 8.2),
which has a fix delay of t
lineout
−
offset
. The "Line Out" is isolated by an opto-isolator from the
camera electronics which leads to an additional delay of t
iso
−
out
.
The maximum exposure offset value t
exposure
−
offset
is up to the read out time of
one image row, when a new exposure starts during read out of the previous
image. In this case, the start of the exposure is postponed to the start of the
next image row read out.
Table B.1 gives an overview of the minimum and maximum values of the timing parameters.
Timing Parameter
Min Value
Max Value
t
iso
−
in
20 ns
165 ns
t
input
−
jitter
100 ns
133 ns
t
pulse
−
delay
0 s
0.559 s
t
exposure
−
offset
50 ns
6.666
µ
s
1)
/ 33.333
µ
s
2)
t
exposure
280
µ
s
1)
/ 1.399 ms
2)
0.559 s
t
timer
−
delay
0 s
143 s
t
timer
−
duration
0 s
143 s
t
lineout
−
offset
133.3 ns
133.3 ns
t
iso
−
out
(ISO_OUT0 and ISO_OUT1)
150 ns
350 ns
t
iso
−
out
(ISO_OUT2)
15 ns
30 ns
Table B.1: MV4 UV Camera timing parameter values of the timed exposure mode (Footnotes:
1)
10 bit mode;
2)
12 bit mode
MAN093 08/2021 V1.1
133 of 143
Содержание MV4 Series
Страница 8: ...CONTENTS 8 of 143 MAN093 08 2021 V1 1 ...
Страница 12: ...1 Preface 12 of 143 MAN093 08 2021 V1 1 ...
Страница 16: ...3 Product Specification Figure 3 1 Photonfocus MV4 UV 10 GigE GT camera series 16 of 143 MAN093 08 2021 V1 1 ...
Страница 40: ...4 Image Acquisition 40 of 143 MAN093 08 2021 V1 1 ...
Страница 42: ...5 Exposure Control 42 of 143 MAN093 08 2021 V1 1 ...
Страница 52: ...6 Counter Timer 52 of 143 MAN093 08 2021 V1 1 ...
Страница 64: ...10 Image Format Control 64 of 143 MAN093 08 2021 V1 1 ...
Страница 66: ...11 Frame Rate 66 of 143 MAN093 08 2021 V1 1 ...
Страница 82: ...12 Pixel Data Processing 82 of 143 MAN093 08 2021 V1 1 ...
Страница 92: ...12 Pixel Data Processing 92 of 143 MAN093 08 2021 V1 1 ...
Страница 96: ...13 Precautions 96 of 143 MAN093 08 2021 V1 1 ...
Страница 120: ...16 Troubleshooting 120 of 143 MAN093 08 2021 V1 1 ...
Страница 126: ...19 Support and Repair 126 of 143 MAN093 08 2021 V1 1 ...
Страница 128: ...20 References 128 of 143 MAN093 08 2021 V1 1 ...
Страница 132: ...A Pinouts 132 of 143 MAN093 08 2021 V1 1 ...