7 Graphical User Interface (GUI)
Trigger Delay:
Programmable delay in milliseconds between the incoming trigger edge and
the start of the exposure.
Trigger signal active low:
Define the trigger signal to be active high (default) or active low.
Burst Trigger
An external trigger event start a predefined number of acquisition. The period time between
the acquisitions can be configured.
Enable Burst Trigger:
Delay in milliseconds from the input trigger edge to the rising edge of
the strobe output signal.
Number of Burst Triggers:
Set the number of burst
Burst Trigger Period [ms
:] Set the time between the burst in milliseconds.
Burst Trigger Delay [ms
:] Set the delay of the burst trigger in milliseconds.
Strobe
The camera generates a strobe output signal that can be used to trigger a strobe. The delay,
pulse width and polarity can be defined by software. To turn off strobe output, set
StrobePulseWidth to 0.
Strobe Delay [ms
:] Delay in milliseconds from the input trigger edge to the rising edge of the
strobe output signal.
Strobe Pulse Width [ms
:] The pulse width of the strobe trigger in milliseconds.
Strobe signal active low:
Define the strobe output to be active high (default) or active low.
74
Содержание MV1-D1312C CameraLink Series
Страница 1: ...User Manual MV1 D1312C CameraLink Series CMOS Area Scan Colour Camera MAN046 04 2010 V1 0...
Страница 2: ......
Страница 4: ...2...
Страница 8: ...CONTENTS 6...
Страница 14: ...2 How to get started CameraLink 12...
Страница 86: ...7 Graphical User Interface GUI 84...
Страница 92: ...9 Warranty 90...
Страница 94: ...10 References 92...
Страница 98: ...A Pinouts 96...
Страница 99: ...B Revision History Revision Date Changes 1 0 March 2010 First release 97...