8 Software
8.10.5
PLC Settings for FrameCombinePulse to ISO_OUT1
This setting connects the FrameCombinePulse signal (see Section 5.1.7) to the output
ISO_OUT1, see Table 8.2 (the visibility in the PF_GEVPlayer must be set to
Guru
for this purpose).
Feature
Value
Category
PLC_I5
PLC_A7
<PLC>/SignalRoutingBlock
PLC_Q1_Variable0
PLC_I5_Not
<PLC>/LookupTable/Q1
PLC_Q1_Operator0
Or
<PLC>/LookupTable/Q1
PLC_Q1_Variable1
Zero
<PLC>/LookupTable/Q1
PLC_Q1_Operator1
Or
<PLC>/LookupTable/Q1
PLC_Q1_Variable2
Zero
<PLC>/LookupTable/Q1
PLC_Q1_Operator2
Or
<PLC>/LookupTable/Q1
PLC_Q1_Variable3
Zero
<PLC>/LookupTable/Q1
Table
8.4:
PLC
Settings
for
FrameCombinePulse
to
ISO_OUT1
(<PLC>
=
in
category
IPEngine/ProgrammableLogicController)
8.11
Miscellaneous Properties
8.11.1
PixelFormat
The property
PixelFormat
(in category
ImageFormatControl
) sets the pixel format. For 10 bits and
12 bits there is a selection of plain or packed format. The plain format uses more bandwidth
than the packed format, but is easier to process in the software. Table 8.5 shows the number of
bits per pixel to are required for a pixel format. Fig. 8.5 shows the bit alignment of the packed
pixel formats.
DataFormat
Bits per pixel
Mono8
8
Mono10Packed
12
Mono12Packed
12
Table 8.5: GigE pixel format overview
The DR1 colour camera models have the
BayerGB8
format. This should be used to
display the debayered colour image in the PF_GEVPlayer display. To demodulate
the image by the SDK the format
Mono8
must be used.
.
118 of 139
MAN077 11/2017 V1.0
Содержание MV1-D1280-L01-1280-G2-12
Страница 1: ...Photonfocus MV1 D1280 L01 Camera Series CMOS camera with GigE interface MAN077 11 2017 V1 0...
Страница 10: ...1 Preface 10 of 139 MAN077 11 2017 V1 0...
Страница 16: ...3 How to get started GigE G2 Figure 3 3 PFInstaller components choice 16 of 139 MAN077 11 2017 V1 0...
Страница 84: ...5 Functionality 84 of 139 MAN077 11 2017 V1 0...
Страница 88: ...6 Precautions 88 of 139 MAN077 11 2017 V1 0...
Страница 120: ...8 Software 120 of 139 MAN077 11 2017 V1 0...
Страница 130: ...12 Support and Repair 130 of 139 MAN077 11 2017 V1 0...
Страница 132: ...13 References 132 of 139 MAN077 11 2017 V1 0...
Страница 136: ...B Camera Revisions 136 of 139 MAN077 11 2017 V1 0...
Страница 138: ...C Feature Matrix 138 of 139 MAN077 11 2017 V1 0...
Страница 139: ...D Document Revision History Revision Date Changes 1 0 November 2017 First version MAN077 11 2017 V1 0 139 of 139...