4 Functionality
4.4.6
Trigger timing values
Table 4.4 shows the values of the trigger timing parameters.
MV1-D1024E-160-CL
MV1-D1024E-160-CL
Timing Parameter
Minimum
Maximum
t
d
−
iso
−
input
45 ns
60 ns
t
jitter
0
25 ns
t
trigger
−
delay
0
0.41 s
t
burst
−
trigger
−
delay
0
0.41 s
t
burst
−
period
−
time
depends on camera settings
0.41 s
t
trigger
−
offset
(non burst mode)
100 ns
duration of 1 row
t
trigger
−
offset
(burst mode)
125 ns
125 ns
t
exposure
10
µ
s
0.41 s
t
strobe
−
delay
0
0.41 s
t
strobe
−
offset
(non burst mode)
100 ns
100 ns
t
strobe
−
offset
(burst mode)
125 ns
125 ns
t
strobe
−
duration
200 ns
0.41 s
t
d
−
iso
−
output
45 ns
60 ns
t
trigger
−
pulsewidth
200 ns
n/a
Number of bursts n
1
30000
Table 4.4: Summary of timing parameters relevant in the external trigger mode using the MV1-D1024E-
160-CL camera
.
42 of 109
MAN064 02/2020 V1.1
Содержание MV1-D1024E
Страница 1: ...Photonfocus MV1 D1024E Camera Series CMOS camera with Camera Link interface MAN064 02 2020 V1 1...
Страница 6: ...CONTENTS 6 of 109 MAN064 02 2020 V1 1...
Страница 10: ...1 Preface 10 of 109 MAN064 02 2020 V1 1...
Страница 14: ...2 How to get started CameraLink Figure 2 4 PFRemote start window 14 of 109 MAN064 02 2020 V1 1...
Страница 68: ...5 Precautions 68 of 109 MAN064 02 2020 V1 1...
Страница 94: ...8 Graphical User Interface GUI 94 of 109 MAN064 02 2020 V1 1...
Страница 104: ...12 References 104 of 109 MAN064 02 2020 V1 1...
Страница 108: ...A Pinouts 108 of 109 MAN064 02 2020 V1 1...