Warning:

Under no circumstances must the 
machine be operated with the door 
open.

Danger:

Risk of injury; unexpected start up 
and electrical shock.
Always disconnect the mains power 
supply before commencing ANY 
cleaning or maintenance on this 
machine.

Danger:

Risk of injury by unexpected start up 
and electrical shock
Always disconnect the mains power 
supply before commencing ANY 
maintenance on this machine.
Have any electrical problems checked 

by a qualified engineer.

Danger:

Never circumvent the door safety 
switch as the LED unit will cause 
severe damage to your eyes.

Caution:

Possible hazardous situation that 
could lead to mild injury to persons or 
damage to property.

This machine is 64 kgs (140 pounds) 
and we recommend that 2 persons 
move this machine to its final 
placement.

When the machine is positioned 
unpack the glass shelf and place 
it inside the unit resting it on the 6 
support pads.
Locate the mains plug lead and plug 
it into the socket on the rear of the 
machine, push the plug in and twist to 
the right to engage the power.

This machine is intended to Cure 3D printed parts 
only inside its enclosure, 
This machine in not intended to work outside without 
suitable protection.

Electrical section

This machine may only be connected to an electrical 
supply which has been installed in accordance with all 
relevant IEC regulations.
This machine has been developed to work on any 
power supply from 105v to 240v AC.
Never permanently connect this machine to the mains 
supply without an isolating switch.
Always check the mains cable for damage prior to use. 
Only authorised persons may replace damaged cables 
to this machine.

Starting/Loading 

On the front of the machine you will see the green 
on/off rocker switch (2) press it in at the bottom and 
it will light up turning the machine control circuits on. 

The machine will not be operated if the door is open

To start the UV cure program, twist the timer switch 
(7) fully clockwise, this will work for 2 hours (you can 
alter this time down to suit your own needs). 

When  the  timer  is  ON  a  small  red  flashing  light  (5) 

is shown on the control panel, a yellow light (6) is 
indicated when the heater is working.

Temperature settings:

The machines temperature is factory set to a 
maximum of 65°c. If you wish to use a lower 
setting you can by pressing the set button on the 
temperature unit once, then pressing the down 
button you can set your machine to the desired 
working temperature. Depending on the country and 
voltage of your machine the heat-up time will vary 
from 5-25 minutes, to ensure accurate and precise 
curing you will need to wait until the temperature 
has reached the selected setting before loading the 
prints into the unit.

Loading:

Open the door and using suitable heat resistant 
gloves place the print platform onto the hanging 
bracket (8). Close the door and reset the timer to 2 
hours.

Unloading: 

Open the door and using suitable heat resistant 
gloves remove the print platform from the hanging 
bracket and close the door to maintain the Cure L’s 
temperature. 
If you are NOT going to place another printed part 
into the unit straightaway, do not close the door 
but you must leave the green switch on to allow the 
heating elements to cool down

Daily checks

Ensure that the inside of the machine is kept clean 
especially the glass covering the UV lights.
Check the condition of the door seal.
Check the mains cable.
Make sure that the vents on top of the machine are 
not covered over.

Machine fails to start 

Does the green switch light come ON?

If no, confirm that you have a working power supply. 

To do this check the fuse in the plug.
If the fuse in the plug is OK then you need to call an 
engineer

Machine has power but the heater fails to work

Check the fuse on the left-hand side of the machine 
(8 amp)
If the fuse is OK call an engineer.

Machine has power but the lights fail to come on

Check the fuse on the left-hand side (2 amp)
If the fuse is OK call an engineer.

10. TROUBLESHOOTING

Recycle: 

Most of the packaging material can 
be recycled. Please do not throw the 
packaging material in to a domestic 
household waste system, send it for 
recycling.

Recycle: 

Remove the outer packaging and 
recycle it.

Recycle: 

Old machines contain valuable 
materials that can be reused or 
recycled; please send your old 
machines to a suitable recycling 
centre at the end of its lifespan.

3

4

CURE L

Содержание CURE L

Страница 1: ...uk www photocentricgroup com UK USA DISPOSAL INSTRUCTIONS Do not throw this electronic device into the waste when discarding To minimize pollution and ensure utmost protection of the global environment please recycle or return to Photocentric for recycling THE NEXT GENERATION OF 3D PRINTING IS HERE CURE L USER MANUAL ...

Страница 2: ...cription of the essential parts of the machine 2 Safety rules 3 Safety devices 4 Environmental protection 5 Intended use 6 Setting up your new machine 7 Before starting the machine 8 Starting stopping 9 Maintenance and care of the machine 10 Troubleshooting 11 Technical specifications 12 Warranty 2 3 3 3 3 3 3 4 4 4 5 5 PHOTOCENTRIC CURE L USER MANUAL CURE L Revision 1 15 10 2019 ...

Страница 3: ...ged or redundant parts or packaging materials Warning Possible hazardous situation that could lead to severe injury to persons or property CURE L CURE L 1 2 2 Internal fan 5 Red flashing led 9 Heater 1 On Off switch 6 Yellow led 10 Door seal 13 Glass shelf 3 Temperature unit 7 Timer switch 11 Rear and bottom UV light 8 Hanging bracket 12 Bottom UV light 4 Temperature adjustment 1 2 3 4 5 6 7 8 9 1...

Страница 4: ... work for 2 hours you can alter this time down to suit your own needs When the timer is ON a small red flashing light 5 is shown on the control panel a yellow light 6 is indicated when the heater is working Temperature settings The machines temperature is factory set to a maximum of 65 c If you wish to use a lower setting you can by pressing the set button on the temperature unit once then pressin...

Страница 5: ...onents Power supply 105 240 ac Power consumption 4 9 amps Noise 43dBA Control devices Control switches 24v dc Transformer 24 vdc 3 The machine package consists of the following 1 Photocentric Cure L 1 power cable We offer 12 months parts only manufacturer s warranty on all mechanical parts All warranty parts are to be returned to us for manufacturer s assessment prior to refunds of parts only repl...

Отзывы: