MM1002a/1202a USER’ S MANUAL

SAFETY PRECAUTIONS

!!! WARNING !!!

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,

DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE.

Avoid exposing rain, water, or any form of liquid to this unit.  IMMEDIATELY unplug its power cord

from its power source and contact a qualified technician when the unit is exposed to rain, water, or

any form of liquid.

Keep the unit is away from heat sources like radiators, heat registers, stoves and etc.

ALWAYS have a qualified technician present when repairing or modifying this unit.

The arrowhead lightning flash symbol within an equilateral triangle is intended to alert you

to the presence of uninsulated “ dangerous voltage”  inside the enclosure that may be suffi-

cient to constitute a risk of shock.

The exclamation point within an equilateral triangle is intended to remind you to the pres-

ence of important operating and maintenance (servicing) instructions in the literature ac-

companying the product.

!!! CAUTION !!!

TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE THE COVER OR THE BACK OF THE UNIT.

No user-serviceable parts inside.  Always contact a qualified technician for repair or modification.

DO NOT

 open, modify, or disassemble the unit without a qualified technician present.  Any change or

repair of the unit requires the present of a qualified technician in order for the warranty to remain

effective.

Clean the unit with damp cloth and dry brush.  No other solvents are recommended for cleaning.

Routine cleaning and proper maintenance guarantee best performance from the unit.

Carefully packed at the manufacturing site, the packing box is designed to protect the unit from rough

handling.  Please carefully examine the content inside the package and make sure the unit is well,

undamaged.

Notify your dealer and the shipping company immediately when you find the unit damaged from ship-

ping.  Claims for damage or replacement would only be granted when reported properly and in a

timely manner.

Use damp cloth or dry brush to clean the unit.

DO NOT

 use any other solvents for cleaning.  Good

care and maintenance of your unit will prolong your unit’ s operational life and insure its optimal

performance.

Содержание MM1002a

Страница 1: ......

Страница 2: ...REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE THE COVER OR THE BACK OF THE UNIT No user serviceable parts inside Always contact a qualified technician for repair or modification DO NOT open modify...

Страница 3: ...EFX OUT 11 17 PHONES 11 18 MAIN OUT 11 19 CTRL RM 11 20 REC 11 21 2T RTN 11 22 LED LEVEL METER 11 23 2T RTN SIGANL PATH SELECT BUTTON 11 24 AUX MM1202a EFX MM1002a SIGNAL PATH SELECT BUTTON 11 25 CTR...

Страница 4: ...or channle 1 4 on master section Pre Fader AUX post fader EFX sends on every input channel REC output 10 segement level meter and switch for MAIN L R and Headphones CTRL RM Headphones output with volu...

Страница 5: ...PHONIC CORPORATION Page 5 MM1002a 1202a USER S MANUAL CONNECTING IT UP...

Страница 6: ...PHONIC CORPORATION Page 6 MM1002a 1202a USER S MANUAL TYPICAL CONNECTING LEAD...

Страница 7: ...Because of the common mode interference immu nity of a balanced system the ground conductor does not need to carry any electrical current which means the ground of the two connected units has an iden...

Страница 8: ...red the cable for best re sult LINE The unbalanced 1 4 TS phone jack accepts line level signal from key boards synthesizer sampler CD or tape recorder Tip is hot and sleeve is ground 2 GAIN This rotar...

Страница 9: ...system dy namic range or increase the possi bility of the unpleasant feedback sound To make sound more impres sive dynamic process is necessary 4 LOW CUT MM1202a ONLY Slide down the slide switch inse...

Страница 10: ...ck to the se lected stereo input channel as effect return Avoid feedback loop by mut ing the EFX rotary knob on this ef fect return channel WARING the EFX knob on this se lected stereo channel has to...

Страница 11: ...ONTROL ROOM There are five seg ments for MM1002a while MM1202a has 10 seg ment LED level meter 23 2T RTN SIGNAL PATH SELECT BUTTON Pushing down the right button feeds the 2T RTN signals into MAIN L R...

Страница 12: ...ould not be plugged in with the 48V switched on 27 HEADPHONES STEREO INDICATION SELECT BUTTON Push down the meter to show headphone level release it to show the main stereo output level 28 MAIN L R FA...

Страница 13: ...procedure Do not turn the output up until they clip and then backing off FOLLOW THE PROCEDURE FOR EACH CHANNEL IN USE Set all faders and gain controls all the way off Phantom powered microphone should...

Страница 14: ...PHONIC CORPORATION Page 14 MM1002a 1202a USER S MANUAL APPLICATIONS USING STEREO INPUT CHANNEL AS EFX RTN...

Страница 15: ...PHONIC CORPORATION Page 15 MM1002a 1202a USER S MANUAL APPLICATIONS PC RECORDING SETUP...

Страница 16: ...PHONIC CORPORATION Page 16 MM1002a 1202a USER S MANUAL DEMINSIONS Measurements are shown in mm inch...

Страница 17: ...PHONIC CORPORATION Page 17 MM1002a 1202a USER S MANUAL SPECIFICATIONS...

Страница 18: ...PHONIC CORPORATION Page 18 MM1002a 1202a USER S MANUAL SYSTEM BLOCK DIAGRAM MM1202a...

Страница 19: ...PHONIC CORPORATION Page 19 MM1002a 1202a USER S MANUAL SYSTEM BLOCK DIAGRAM MM1002a...

Страница 20: ......

Отзывы: