SCADA 3000 User’s Manual

Appendix B: Returning Module for Service

In the event that the Annunciator Module does not function properly, we suggest that you do
the following:

1)  Record your observations regarding the Annunciator Module malfunction.

2)  Call the Customer Service Department at (610)558-2700 prior to sending the
unit to Phonetics for repair.

If the module must be sent to Phonetics for Servicing, please do the following:

1)  Disconnect all wiring and unplug the unit.

Note that the terminal blocks can be unplugged from the unit to maintain
your input wiring.

2)  Carefully pack the module to avoid damage in transit.  Use the original container
(if available) or a sturdy shipping box.

3)  You must include the following information to avoid shipping  delays:

a) Your name, address and telephone number.

b) A note explaining the problem.

4)  Ship your package to the address below:

SERVICE DEPARTMENT

Phonetics Inc.

901 Tryens Road

Aston, PA  19014

5)  Ship prepaid and insured via UPS or US Mail to ensure a traceable shipment with
recourse for damage or replacement.

Important Information for Canadian Customers

In the event that your Sensaphone SCADA 3000 unit does not function properly, Canadian
customers have the option of shipping the unit to one of the following Phonetics-authorized
Canadian Repair facilities:

Microwise Computer Systems

G.A.S. Analytical Systems, Ltd.

100 Covington Crescent

Head Office

Kitchener, Ontario N2N 2X3

Bay V, 1338 36 Avenue NE

(519) 744-9892

Calgary, Alberta  T2E 6T6
(403) 253-6576

Please record your observations regarding the unit’s malfunction and follow the procedures
outlined on the previous page.

For Technical Support questions, you may call Phonetics Technical Service Department at (610)
558-2700, or by E-mail at [email protected].

Содержание Annunciator Module SCADA 3000

Страница 1: ...AM 1 Annunciator Module SCADA 3000 ANNUNCIATOR MODULE...

Страница 2: ...in equipment made by other manu facturers and referred to in this manual will not affect the applicability of the information in this manual Copyright 1999 by Phonetics Inc First Edition version 1 0...

Страница 3: ...in a risk of fire or electric shock To reduce the risk of electric shock do not disassemble this product but return it to Phonetics Customer Service or another approved repair facility when any servic...

Страница 4: ...chnical Support 5 Installation 6 OPERATING ENVIRONMENT 6 MOUNTING THE ANNUNCIATOR MODULE 6 Labeling 7 Power Supply and Grounding 7 Communications Wiring 8 Bus Termination 9 How the Annunciator Module...

Страница 5: ...r as two state ON OFF outputs in the SCADA 3000 software The Annunciator module is housed in a 1 8 DIN enclosure for convenient panel mounting Technical Support If any questions arise upon installatio...

Страница 6: ...he Annunciator Module can operate in is 32 F to 158 F 0 C to 70 C If you require Annunciator Module to operate in a below freezing environment you must take safe and practical measures to keep the mod...

Страница 7: ...ed from the AUX PWR terminals on the SCADA 3000 main unit This is preferred because the AUX PWR from the main unit is battery backed in the event of a power failure when a battery is connected to the...

Страница 8: ...one pair for A B and the other pair for Z Y The proper wiring from the main unit to the modules and from module to module is shown in Figure 3 A B Z Y Y Z B A Y Z B A Y Z B A SCADA 3000 Module Module...

Страница 9: ...he communications network to minimize signal reflections that would otherwise cause data communication errors To activate the Bus Termina tion move the jumper to the IN position Note that this should...

Страница 10: ...in unit screen The Annunciator module provides eight LED indicators which can be used to display the status of I O points system variables or alarm conditions The LEDs can be forced on Red or off Ambe...

Страница 11: ...a m k c i W 5 R T e z i S V 0 5 2 A m 0 0 5 e r u t a r e p m e t g n i t a r e p O F s e e r g e d 8 5 1 o t 2 3 s u i s l e C s e e r g e d 0 7 o t 0 e r u t a r e p m e T e g a r o t S F s e e r g...

Страница 12: ...and telephone number b A note explaining the problem 4 Ship your package to the address below SERVICE DEPARTMENT Phonetics Inc 901 Tryens Road Aston PA 19014 5 Ship prepaid and insured via UPS or US M...

Страница 13: ...QUENTIAL DAMAGES It must be clear that the warrantors are not insuring your premises or guaranteeing that there will not be damage to your person or property if you use this Product The warrantors sha...

Отзывы: