background image

2

www.UsePhoenix.com • [email protected]

Toll-Free 1-800-533-7533

Table of Contents

Introduction

  ............................................................................1

1.   Safety Certifications

  .......................................................2

2.   Specifications

  .................................................................2

3.   Operation

  ........................................................................2

 

3.1 Transporting  ..............................................................2

 

3.2 Location .....................................................................3

 

3.3 Electrical Requirements  ...........................................3

 

3.4 Condensate Removal  ...............................................3

 

3.5 Ducting  ......................................................................3

 

3.6 Defrost Cycle  .............................................................3

 

3.7 Power Button  ............................................................3

 

3.8 Purge Button  .............................................................3

 

3.9 Hour Meter  ................................................................3

 

3.10 Hours Button  ..........................................................3

 

3.11 Defrost Light  ...........................................................4

 

3.12 Bypass Control  .......................................................4

4.   Maintenance

  ...................................................................4

 

4.1 Air Filter  .....................................................................4

 

4.2 Storage  ......................................................................4

5.   Service

  .............................................................................4

 

5.1 Technical Description  ...............................................4

 

5.2 Troubleshooting  ........................................................5

 

5.3 Air Mover  ...................................................................6

 

5.4 Thermistor  .................................................................6

 

5.5 Condensate Pump  ....................................................6

 

5.6 Float Safety Switch  ...................................................6

6.   Options & Accessories

  ...................................................7

7.   Wiring Diagram

  ..............................................................7

8.   Service Parts

  ...................................................................8

9. Warranty

  ..........................................................................9

1 Safety Certifications

The Phoenix R250 conforms to unified standard UL 60335-

2-40.

2 Specifications

Part No.

 4034460

Power

 

8.3 amps, 120 VAC, Grounded

Water

 

135 pints/day @ AHAM (80°F, 60%) 

Removal

 

Blower

 

310 CFM without external ducting 

Refrigerant 

2 lb, 0 oz. R-410A 

Charge 
Operating

  

33°F to 110°F 

Range

  

Filters:

 

12” x 12” x  1” Pleated Media MERV-11

Duct

 

Inlet – 12” Flex-Duct

 

Options

 

Outlet – 10” Lay-Flat 

  

Warranty

 

Five years; 

 

1st year 100% of Parts and Labor 

 

2nd-5th year 100% of sealed refrigeration    

 

system parts.

Dimensions

 

Unit Shipping 

Width 20” 

21” 

Height 33.5” 

35.25” 

Depth 20” 

21” 

Weight 

109 lbs 

125 lbs

Patent -  7,246,503 

 D570,988 

 8,069,681 

            

3 Operation

Place dehumidifier inside structure, 

place condensate hose into a drain, or a 

large water tight container, and turn on. 

To decrease drying times, make sure all 

windows and doors are closed to the outside 

and seal off the affected wet areas from 

unaffected areas. 
Optimum performance will be observed 

between the temperatures of 70°F and 

95°F.

3.1 Transporting

The Phoenix R250 must always be upright when transported 

by vehicle. It may be tipped on to its handle and back for 

loading and moving by hand. 
If the unit is transported on its side, let it sit upright at least 

30 minutes before use.

Read the operation and maintenance instructions 

carefully before using this unit. Proper adherence to these 

instructions is essential to obtain maximum benefit from 

your Phoenix R250 dehumidifier.

•  It is designed to be used 

INDOORS ONLY.

•  If used in a wet area, plug it into a 

GROUND FAULT 

INTERRUPTER

.

• 

DO NOT

 use the Phoenix R250 as a bench or table.

•  It must always be used in the upright position.

Figure 1: Stacked  

Phoenix R250 

Содержание R250

Страница 1: ... Filter A 12 x12 x1 MERV 11 filter is standard Stacking Nesting Reduces space for ease of stacking and storage Patented ByPass Technology Increased performance over a wide temperature range Specifications subject to change without notice TS 889 08 15 4201 Lien Rd Madison WI 53704 Phoenix R250 Part No 4034460 Patent 7 246 503 D570 988 8 069 681 The Phoenix R250 has been redesigned from the inside o...

Страница 2: ...at Warranty Five years 1st year 100 of Parts and Labor 2nd 5th year 100 of sealed refrigeration system parts Dimensions Unit Shipping Width 20 21 Height 33 5 35 25 Depth 20 21 Weight 109 lbs 125 lbs Patent 7 246 503 D570 988 8 069 681 3 Operation Place dehumidifier inside structure place condensate hose into a drain or a large water tight container and turn on To decrease drying times make sure al...

Страница 3: ...ng the spiral wire under the four tabs Tape the duct to the top cover for a complete seal 3 6 Defrost Cycle If the low side refrigerant temperature drops below the defrost set point due to excessive frost formation on the evaporator coil the thermistor activates the solid state control and the defrost light The control cycles the compressor off and on by the thermistor temperature measurement The ...

Страница 4: ...uld become clogged and require disassembly to clean 4 2 Storage There are two issues to consider when the Phoenix R250 is stored between uses and both pertain to the water trapped in the unit damage caused by freezing or biological growth The effect of the trapped water can be greatly reduced if precautions are taken to remove as much as possible before storage 1 Use the pump PURGE button to reduc...

Страница 5: ...ontinuously but compressor only runs sporadically 1 Unit is in defrost cycle DEFROST light on 2 Defrost thermistor defective or loose 3 Loose connection in compressor circuit 4 Defective compressor overload 5 Defective compressor 6 Defective relay 7 Upper housing is not sealed to lower housing No dehumidification air mover runs but compressor does not 1 Bad connection in compressor circuit 2 Safet...

Страница 6: ... Reassemble thermistor and dehumidifier using the above procedure in reverse Figure 10 Picture of the float safety switch 5 5 Condensate Pump The internal condensate pump removes water that collects in the reservoir To replace the condensate pump 1 Unplug the unit 2 Remove the front housing 3 Unplug the pump wires from the wire harness 4 Remove the condensate hose and the one screw attaching the p...

Страница 7: ...BLK 3 YEL 7 E1 E3 E2 E5 E4 BLK 5 BRN 6 BLK 12 BLU 18 BLK 4 WHT S R C 4026354 C Figure 11 Wiring diagram 7 www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 6 Options Accessories 4024750 Inlet Flex Duct 12 x 25 Metallize Polyester 4024935 Lay Flat Duct 10 Round x 250 Roll To order contact Therma Stor LLC at 1 800 533 7533 7 Wiring Diagram ...

Страница 8: ...ord 1 4032315 14 Control Board 1 4026763 15 Capacitor Compressor 50 μF 1 4033032 06 16 Capacitor Impeller 15 μF 1 4033031 07 17 Thermistor 1 4031279 18 Handle lever 1 4026350 Description Qty Part No Compressor 1 4035407 Evaporator Coil 1 4033995 02 Condenser Coil 1 4033996 Condensate Pump 1 4034582 01 Float Safety Switch 1 4034374 Description Qty Part No Impeller Air Mover 1 4026657 Exhaust Grill ...

Страница 9: ...The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control Limitation and Exclusions If any Phoenix R250 Dehumidifier part is repaired...

Отзывы: