Table of Contents

Introduction

  ............................................................................1

1.   Safety Certifications

  .......................................................2

2.   Specifications

  .................................................................2

3.   Operation

  ........................................................................2

 

3.1 Transporting  ..............................................................2

 

3.2 Electrical Requirements  ...........................................3

 

3.3 Condensate Removal  ...............................................3

 

3.4 Ducting  ......................................................................3

 

3.5 Defrost Cycle  .............................................................3

 

3.6 Power Button  ............................................................3

 

3.7 Purge Button  .............................................................3

 

3.8 Hour Meter  ................................................................3

 

3.9 Hours Button  ............................................................3

 

3.10 Defrost Light  ...........................................................3

4.   Maintenance

  ...................................................................4

 

4.1 Air Filter  .....................................................................4

 

4.2 Storage  ......................................................................4

5.   Service

  .............................................................................4

 

5.1 Technical Description  ...............................................4

 

5.2 Troubleshooting  ........................................................5

 

5.3 Air Mover  ...................................................................6

 

5.4 Thermistor  .................................................................6

 

5.5 Condensate Pump  ....................................................6

 

5.6 Float Safety Switch  ...................................................6

6.   Options & Accessories

  ...................................................6

7.   Wiring Diagram

  ..............................................................7

8.   Service Parts

  ...................................................................8

 Warranty

  ..........................................................................9

1 Safety Certifications

The Phoenix R125 conforms to standards ANSI/UL 474 and 

CSA C22.2 No.92.

2 Specifications

Part No.

 

4032350

Power

 

5.0 amps, 110-120 VAC, Grounded

Water

 

65 pints/day @ AHAM (80°F, 60%) 

Removal

 

16 gal/day maximum @ saturation

Process Air

  170 CFM without external ducting  

Refrigerant 

1 lb, 2 oz. R410a 

Charge 
Operating

  

33°F to 100°F 

Range

  

Filter

 

12” x 12” x  1” Pleated Media MERV-8

Duct

 

 

Options

 

Exhaust – 10” Lay-Flat 

  

Warranty

 

Five years; 

 

1st year 100% of Parts and Labor 

 

2nd-5th year 100% of Parts of sealed 

 

refrigeration system.

Size 

30” high x 20” wide x 17” deep

Weight

 

79 lbs

3 Operation

Place dehumidifier inside structure, 

place condensate hose into a drain, or 

a very large container, and turn on. To 

decrease drying times, make sure all 

windows and doors are closed to the 

outside and seal off the wet area from 

any unaffected areas.

 

3.1 Transporting 

The Phoenix R125 features a high-impact roto-molded hous-

ing which protects the unit while loading into vehicles. The 

unit was designed to stack 2 units high. For sturdy stack-

ing, keep the rotating handle in the upright position on the 

bottom unit, place rotating handle in the down position and 

“nest” the wheels of the top unit in the indentions of the bot-

tom unit to provide stability. This is recommended for storage 

only. The units should be properly secured for transport. The 

Phoenix R125 must always be upright when transported by 

vehicle. It may be tipped onto its handle and back for loading 

and moving by hand.

Read the operation and maintenance instructions 

carefully before using this unit. Proper adherence to these 

instructions is essential to obtain maximum benefit from 

your Phoenix R125 dehumidifier.

• It is designed to be used 

INDOORS ONLY.

• If used in a wet area, plug it into a 

GROUND FAULT 

INTERRUPTER

.

• 

DO NOT

 use the Phoenix R125 as a bench or table.

• It must always be used in the upright position.

Stacked Phoenix R125

Содержание R125 LGR

Страница 1: ...into a small portable and durable roto mold housing In addition to the R125 s compact size and superior performance the unit features high energy efficiency front cord and hose storage a ductable outlet a pleated media filter and a rotating handle for easy transport and storage The Phoenix R125 LGR Dehumidifier LGR Performance in a 79 lb 20 x 17 footprint Removes 65 pints at AHAM drawing only 5 0 ...

Страница 2: ...tem Size 30 high x 20 wide x 17 deep Weight 79 lbs 3 Operation Place dehumidifier inside structure place condensate hose into a drain or a very large container and turn on To decrease drying times make sure all windows and doors are closed to the outside and seal off the wet area from any unaffected areas 3 1 Transporting The Phoenix R125 features a high impact roto molded hous ing which protects ...

Страница 3: ...ll continue to run causing air to flow through the evaporator coil and melt the ice when the compressor is off When the air temperature and or humidity increases the evaporator temperature will rise and the thermistor will end the defrost cycle at the temperature set point 3 6 POWER Button Press the POWER button to turn the dehumidifier on or off When starting the dehumidifier the display will sho...

Страница 4: ... that it drains into the heat exchanger 4 Use PURGE button to remove chemicals in reservoir Run PURGE until hose runs dry 5 Walk out hose to drain completely 6 Replace air filter 5 Service WARNING Servicing the Phoenix R125 with its high pressure refrigerant system and high voltage circuitry presents a health hazard which could result in death serious bodily injury and or property damage Only qual...

Страница 5: ... compressor overload 5 Defective compressor 6 Defective control board Air mover does not run Compressor runs briefly but cycles on and off 1 Loose connection in blower circuit 2 Obstruction prevents impeller rotation 3 Defective air mover Unit removes some water but not as much as expected 1 Air temperature and or humidity have dropped 2 Humidity meter and or thermometer used are out of calibratio...

Страница 6: ...place the pump hose wiring bolts and housing in the reverse order 6 Options Accessories 4026315 Air Filter Pleated 12 x 12 x 1 MERV 8 4025568 Air Filter Pleated 12 x 12 x 1 MERV 11 4024935 Lay Flat Duct 10 Round x 250 Roll To order contact Therma Stor LLC at 1 800 533 7533 5 3 Air Mover The motorized impeller has a PSC motor and internal thermal overload protection If defective the complete assemb...

Страница 7: ...2 BLK 16 WHT 2 WHT 7 BLK 3 GRN BLU 8 BLK 4 BLK 11 YEL YEL BLU YEL YEL 10 RED 9 WHT 7 BLK GRY WHT 6 CONTROL BOARD RUN CAP FAN MOTOR PUMP SAFETY NO NC FLOAT WHT PUMP FAN LEVEL SWITCH THERMISTOR 1 LINE 2 NEUT 3 COMP RUN CAP PLUG 5 4 C R S COMPRESSOR BLK 15 BLK P N 4031273 REV C Wiring diagram 7 Wiring Diagram ...

Страница 8: ...or 1 4029567 9 Thermistor Probe 1 4034716 02 10 Capacitor Impeller 6 0 μF 1 4033031 03 11 Hex Bolts 1 4 20 x 1 50 6 1154013 12 Handle Bar 1 4031267 13 Handle Grip 1 4031268 14 Wheel 12 Gray 2 4026304 15 Cotter Pin 2 1284404 16 Hub Cap Wheel Gray 2 4027137 17 Handle Knob 2 4032327 18 Control Board 1 4034457 19 Power Cord 1 4032297 Items listed are not shown Description Qty Part No Hose 1 4 ID x 33 ...

Страница 9: ...The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control Limitation and Exclusions If any Phoenix R125 Dehumidifier part is repaired...

Отзывы: