6.
SERVICING AND MAINTENANCE :
All maintenance must be carried out when the duster is disconnected from
the tractor. There is no requirement to use special tools.
It is necessary to store the duster with the dust tank absolutely empty.
Do not wash the duster with water or similar liquids.
It is advisable to lubricate the dust cap on the bottom of the tank at least once
year at the end of each treatment in the case of remote flow control. In order
to lubricate, close the dust flow lever and with the aid of an oiler inside the
tank, oil the perforations on the bottom; afterwards activate the lever to open
and close several times.
Before every treatment check visually the oil level from speculates of the
multiplier.
If necessary fill up the oil level with lubricant EP 200. Replace completely the
oil from the multiplier after 500 worked hours (Quantity Lt 0.3 for HD 11
series). Every 200 hours check the degree of viscosity and purity oil with
outside temperatures of 40 degree centigrade and more, one advises to use
synthetic oil.