Phoenix DrySENSE Скачать руководство пользователя страница 7

QUICK START GUIDE

DrySENSE 

Moisture Reader

USEPHOENIX.COM  

|

  800-533-7533

The same process can 

be used to automate 

the Unaffected Area or 

an HVAC reading.

How to insert the DrySENSE into Drywall

How to insert the DrySENSE with attachment into 

other supported materials. 

(Not meant for concrete. If you have concrete, use 

noninvasive meter or relative humidity probe taped to 

surface.)

The DrySENSE should be stored in a water resistant 

container that will also protect the DrySENSE against 

being dropped.

Using the DrySENSE with the DryPHONE allows you 

to receive alerts when the moisture point is reached, 

or the chamber or the job is dry. It provides the 

ability to take daily readings remotely as needed, and 

allows you to check on conditions of the job remotely 

and schedule your visits based on the jobsite 

conditions.

Attaching your DrySENSE

QUICK START GUIDE

Содержание DrySENSE

Страница 1: ...isit usephoenix com phoenix drylink mobile app Scan QR code for more information on DryLINK TS 1189 10 20 Rev A USEPHOENIX COM 800 533 7533 Check the pins to make sure they are screwed in tightly The DrySENSE takes two AA batteries included Remove the battery cover and insert the batteries Turn on the DrySENSE the light will flash green Before you start we recommend you inspect the accessories to ...

Страница 2: ...fier or used as a standalone thermo hygrometer to automate the readings for an affected area unaffected area or HVAC If you choose to mount the DrySENSE on a dehumidifier please see our mounting instructions before continuing Adding your DrySENSE in the DryLINK app Add DrySENSE to your company s inventory The DrySENSE can be used as a penetrating meter and or as a standalone thermo hygrometer ...

Страница 3: ...Use the target to identify the unit Pressing the target will make the LED on the unit flash You can click MANUAL ENTRY if you don t want to use a DrySENSE at all After creating a job in DryLINK select that job and in the DRYING DATA tab click to create a new visit In the Visit select the MOISTURE READINGS tab Select the chamber you want to add a moisture point to In this case it would be Demo cham...

Страница 4: ...e Reader USEPHOENIX COM 800 533 7533 Select Location and Material and click SAVE FINISH After clicking SAVE FINISH you will see the following message click OK Click ADD MOISTURE POINT to add another moisture point Click DONE to complete ...

Страница 5: ...the DRYING DATA tab and click the in the lower left to take your first daily reading When you click COLLECT READING and smart equipment is in range and can be used to automate readings they will be displayed in the list Click on the unit you want to use to automate this reading You can click MANUAL ENTRY if you don t want to use a DrySENSE at all By clicking COLLECT READING you will see the Unaffe...

Страница 6: ...QUICK START GUIDE DrySENSE Moisture Reader USEPHOENIX COM 800 533 7533 Your first reading will show up in the Drying Log Entry Future daily readings for this job will not be automatically entered ...

Страница 7: ...ninvasive meter or relative humidity probe taped to surface The DrySENSE should be stored in a water resistant container that will also protect the DrySENSE against being dropped Using the DrySENSE with the DryPHONE allows you to receive alerts when the moisture point is reached or the chamber or the job is dry It provides the ability to take daily readings remotely as needed and allows you to che...

Отзывы: