3.5 Ducting

A wire duct collar is supplied to allow 10” lay-flat duct to 

be attached to the Phoenix DryMAX outlet. Lay-flat plastic 

ducting is available; see section 6 Options and Accessories. 

To attach ducting to the wire duct collar, put the plastic duct 

end through the collar center and roll the duct end outward 

so that it overlaps the outside of the collar. The duct and 

collar may then be quickly attached to the Phoenix DryMAX 

by snapping the collar over the four exhaust tabs. 

3.6 Defrost Cycle

If the low side refrigerant temperature drops due to 

excessive frost formation on the evaporator coil and below 

the temperature set point, the thermistor activates the PLC 

and Status Light Indicator. The compressor is cycled off and 

on by the thermistor temperature measurement. The air 

mover will continue to run, causing air to flow through the 

evaporator coil and melt the ice when the compressor is off. 

When the air temperature and/or humidity increases, the 

evaporator temperature will rise and the thermistor will end 

the defrost cycle at the temperature set point

3.7 POWER Button

When the dehumidifier is plugged in it will enter stand-by 

mode.  

Press the

POWER

button to turn the dehumidifier on. The unit 

will begin the Powering Up sequence and you will see this 

screen:

Press and hold the

POWER

 to turn the dehumidifier off. The 

dehumidifier will go through a powering-down cycle.  

The default shut-down time is three minutes plus 20 

seconds for a final purge. The shutdown time can be 

changed be scrolling through the menu to this screen.

***IMPORTANT***

 - Unplugging the unit without running 

the shutdown sequence will allow water to remain in the unit 

after use.  If the unit is tilted more than 20 degrees on the 

non-handle side, water may spill out of unit.

3.8 PURGE Button

During normal operation the pump automatically cycles 

when the reservoir is full. 
 

Press the

PURGE

 button to remove condensate manually 

from the reservoir.

4 Maintenance

4.1 Air Filter

The Phoenix DryMAX is equipped with a pleated media air 

filter that must be checked regularly. The standard filter 

is a MERV-10 high efficiency filter. Operating the unit with 

a dirty filter will reduce the dehumidifier’s capacity and 

efficiency and may cause the compressor to cycle off and on 

unnecessarily. The filter can generally be vacuumed clean 

several times before needing replacement. Replacement 

filters can be ordered from the manufacturer or purchased 

locally if available IMPORTANT: DO NOT operate the 

unit without the filter or with a less effective filter as the 

coils inside the unit could become clogged and require 

disassembly to clean. 

Содержание DryMAX 4036000

Страница 1: ...nit The Phoenix DryMAX is 6 smaller than the closest dehumidifier and yet it still has an integrated handle and wheels as well as onboard storage for the power cord and condensate hose The all new Phoenix Micro Channel condenser allows us to pack so much performance into such a small dehumidifier The feedback on the stacking of the AirMAX was so positive we made sure to build it into the Phoenix D...

Страница 2: ... make sure all windows and doors are closed to the outside and seal off the wet area from any unaffected areas 3 1 Transporting The Phoenix DryMAX features a high impact roto molded housing which protects the unit It is recommended the units are properly secured for transport The Phoenix DryMAX must always be on its base when transported by vehicle It may be tipped upright to utilize its handle an...

Страница 3: ...XT key to advance to the next screen or to enter a value Press the key to scroll through available values 3 3 4 Purging Press the PURGE button to purge the machine The display will communicate to the user that the machine is purging on the fourth line of the dashboard and show a 20 second countdown timer This will momentarily replace grain depression until the machine has finished purging The disp...

Страница 4: ...ction and advance to the next screen Light Bar On The light bar colors and animations will persist while in Settings 3 3 9 Humidistat Fan Mode Press the Set button to toggle the Humidistat Fan mode from Always On to Auto Press the Next button to confirm selection and advance to the next screen Light Bar On The light bar colors and animations will persist while in Settings 3 3 10 Humidity Units Pre...

Страница 5: ...4 Language The display will greet the user in order to help them identify the language settings for the machine Press the Set button to browse available languages Press the Next button to confirm selection and advance to the next screen Light Bar On The light bar colors and animations will persist while in Settings 3 3 15 About This Device The following information is displayed on the About this D...

Страница 6: ...y will communicate to the user the following information during a Refrigeration Test Inlet Temperature and RH Grains Outlet Temperature and RH Grains Hours Life hours only Evaporator Coil Temperature Countdown timer 20 minutes Once the 20 minute countdown timer has expired the display will automatically advance to show the refrigeration test results The display will communicate to the user either ...

Страница 7: ...ehumidifier on The unit will begin the Powering Up sequence and you will see this screen Press and hold the POWER to turn the dehumidifier off The dehumidifier will go through a powering down cycle The default shut down time is three minutes plus 20 seconds for a final purge The shutdown time can be changed be scrolling through the menu to this screen IMPORTANT Unplugging the unit without running ...

Страница 8: ...n air conditioner s to remove moisture from incoming air and to add heat to the air that is discharged Hot high pressure refrigerant gas is routed from the compressor to the condenser coil The refrigerant is cooled and condensed by giving up its heat to the air that is about to be discharged from the unit The refrigerant liquid then passes through a filter drier and capillary tubing which cause th...

Страница 9: ... thermistor probe 1 Unplug the dehumidifier 2 Remove the top housing 3 Pull thermistor probe up and out of evaporator coil 4 Remove control board cover 5 Unthread thermistor probe wire from harness 6 Unplug thermistor probe connector on control board 7 Reassemble thermistor probe and dehumidifier using the above procedure in reverse 5 5 Condensate Pump The internal condensate pump removes water th...

Страница 10: ...9 BLK 11 BRN BLK BLK 13 BLK 5 BLK BLOWER BLU GRN BLK 4 BLK 13 BLK 5 RH IN RH OUT AUX EVAP FLOAT TEMP RH SENSOR TEMP RH SENSOR PRESS SWITCH THERMISTOR PROBE 1 2 3 4 5 6 LINE NEU WHT 10 WHT 6 WHT 12 WHT 6 WHT 10 WHT FLOAT SWITCH PUMP BLK CORD WHT CORD P N 4036955 CONTROL BOARD POWER BOARD COMPRESSOR CAPACITOR ...

Страница 11: ...11 USEPHOENIX COM 1 800 533 7533 Toll Free 1 800 533 7533 8 Service Parts ...

Страница 12: ...fect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control Limitation and Exclusions If any Phoenix DryMAX Dehumidifier part is repaired or replaced the new part shall be warranted for only the remainder of the or...

Отзывы: