cause the refrigerant pressure and temperature to drop. It 
next enters the evaporator coil where it absorbs heat from 
the incoming air and evaporates.
The evaporator operates in a flooded condition, which 
means that all the evaporator tubes contain liquid 
refrigerant during normal operation. A flooded evaporator 
should maintain constant pressure and temperature 
across the entire coil, from inlet to outlet.
The mixture of gas and liquid refrigerant enter the 
accumulator after leaving the evaporator coil. The 
accumulator prevents any liquid refrigerant from reaching 
the compressor. The compressor evacuates the cool 
refrigerant gas from the accumulator and compresses it to 
a high pressure and temperature to repeat the process.

4.2 Troubleshooting

No dehumidification, neither blower nor compressor run 
and power switch does not light when ON.

.   Unit unplugged or no power to outlet.
2.   Power switch defective.
3.   Loose connection in internal wiring.

No dehumidification, neither blower nor compressor run 
with power switch ON and lit.

.   Low pressure control open.
2.   Power switch defective.
3.   Loose connection in internal wiring.
4.  Check thermostat setting.

Some dehumidification, blower runs continuously but 
compressor only runs sporadically.

.   Unit is in defrost cycle.
2.   Defrost thermostat defective or loose.
3.   Loose connection in compressor circuit.
4.   Defective compressor overload.
5.   Defective compressor.
6.   Defective relay.

Figure 5: Refrigeration system

No dehumidification, blower runs but compressor does not.

.   Bad connection in compressor circuit.
2.   Pump safety switch closed.
3.   Defective compressor capacitor.
4.   Defective compressor overload.
5.   Defective compressor.
6.   Defective relay.

Blower does not run. Compressor runs briefly but cycles on 
and off.

.   Loose connection in blower circuit.
2.   Obstruction prevents impeller rotation.
3.   Defective blower.

Unit removes some water but not as much as expected.

.   Air temperature and/or humidity have dropped.
2.   Humidity meter and/or thermometer used are out of 

calibration.

3.   Unit has entered defrost cycle.
4.   Air filter dirty.
5.   Defrost timer incorrectly set for conditions.
6.   Defective defrost thermostat.
7.   Low refrigerant charge.
8.   Air leak such as loose cover.
9.   Defective compressor.
0. Restrictive exhaust ducting.

Unit runs but does not pump water.

.   Hose kinked or plugged.
2.   Pump motor or float switch defective.
3.   Pump check valve plugged.
4.   Bad connection in pump circuit.
5.   Hose disconnected internally.

Unit pumps water automatically but not when purge switch 
is pushed.

.   Bad connection in purge switch circuit.
2.   Defective purge switch.

Evaporator coil frosted continuously, low dehumidifying 
capacity.

.   Defrost thermostat loose or defective.
2.   Defrost timer incorrectly set or defective.
3.   Low refrigerant charge.
4.   Dirty air filter or air flow restricted.

Compressor runs with power switch OFF.

.   Defective relay.
2.   Defective power switch.

Содержание Arctic Max TS-388

Страница 1: ...humidifiers When used in conjunction with the Phoenix Solution LGR performance amplifier the Phoenix Arctic Max provides a reliable cooling air stream to maximize overall performance The Phoenix Arcti...

Страница 2: ...s carefully before using this unit Proper adherence to these instructions is essential to obtain maximum benefit from your Phoenix Arctic Max dehumidifier It is designed to be used INDOORS ONLY If use...

Страница 3: ...ng into vehicles 2 2 Electrical Requirements The Phoenix Arctic Max plugs into a common grounded outlet on a 15 Amp circuit It draws 11 7 Amps at 95 F 60 RH If used in a wet area a ground fault interr...

Страница 4: ...be ordered from the factory or purchased locally if available WARNING DO NOT operate the unit without the filter or with a less effective filter as the heat exchange coils inside the unit could become...

Страница 5: ...3 Loose connection in compressor circuit 4 Defective compressor overload 5 Defective compressor 6 Defective relay Figure 5 Refrigeration system No dehumidification blower runs but compressor does not...

Страница 6: ...h or if the pump purge switch is held in To replace the condensate pump 1 Remove the metal strap holding the pump by loosening the 2 screws holding it in place 2 Disconnect the leads 3 Installation is...

Страница 7: ...r LLC PO BOX 8680 MADISON WI 53708 CAP YEL RED WHT WHT WHT BLU COMPRESSOR COMP BLK BLOWER CONTROL BLK BLK 5 3 2 MOTOR DEFROST 1 TIMER MOTOR SWITCH TIMER WHT VIO 1 DEFROST TIMER CONTROL THERMOSTAT BLK...

Страница 8: ...254 15 Condensate Pump 1 4023649 16 10 Wire Duct Collar Cooling 1 4024078 17 Top 1 4026842 18 Handle Assembly 1 4026094 19 Pump Purge Switch 1 4021796 20 Hour Meter 1 4021597 21 Power Switch 1 4021822...

Страница 9: ...s warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident...

Отзывы: