Phoenix Solution LRG Performance Amplifier Limited Warranty

Warrantor:

Therma-Stor LLC
4201 Lien Rd
Madison, WI 53704
Telephone: 1-800-533-7533

Who Is Covered:

 This warranty extends only to the original end-user of the Phoenix Solution LGR 

Amplifier, and may not be assigned or transferred.

Year One:

 Therma-Stor LLC warrants that, for one (1) year the Phoenix Solution LGR Amplifier will 

operate free from any defects in materials and workmanship, or Therma-Stor LLC will, at its option, 
repair or replace the defective part(s), free of any charge.

End-User Responsibilities:

 Warranty service must be performed by a Servicer authorized by 

Therma-Stor LLC. If the end-user is unable to locate or obtain warranty service from an authorized 
Servicer, he should call Therma-Stor LLC at the above number and ask for the Therma-Stor Service 
Department, which will then arrange for covered warranty service. Warranty service will be performed 
during normal working hours.
The end-user must present proof of purchase upon request, by use of the warranty card or other 
reasonable and reliable means. The end-user is responsible for normal care. This warranty does 
not cover any defect, malfunction, etc. resulting from misuse, abuse, lack of normal care, corrosion, 
freezing, tampering, modification, unauthorized or improper repair or installation, accident, acts of 
nature or any other cause beyond Therma-Stor LLC’s reasonable control.

Limitation and Exclusions:

 If any Phoenix Solution LGR Amplifier part is repaired or replaced, the 

new part shall be warranted for only the remainder of the original warranty period applicable thereto 
(but all warranty periods will be extended by the period of time, if any, that the Phoenix Solution LGR 
Amplifier is out of service while awaiting covered warranty service).
UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE PHOENIX SOLUTION 
LGR AMPLIFIER OR ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, INCLUDING 
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. ALL 
WARRANTIES MADE BY THERMA-STOR LLC ARE SET FORTH HEREIN, AND NO CLAIM MAY BE MADE 
AGAINST THERMA-STOR LLC BASED ON ANY ORAL WARRANTY. IN NO EVENT SHALL THERMA-STOR 
LLC, IN CONNECTION WITH THE SALE, INSTALLATION, USE, REPAIR OR REPLACEMENT OF ANY 
SOLUTION OR PART THEREOF BE LIABLE UNDER ANY LEGAL THEORY FOR ANY SPECIAL, INDIRECT 
OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION WATER DAMAGE (THE END-USER 
SHOULD TAKE PRECAUTIONS AGAINST SAME), LOST PROFITS, DELAY, OR LOSS OF USE OR DAMAGE 
TO ANY REAL OR PERSONAL PROPERTY.
Some states do not allow limitations on how long an implied warranty lasts, and some do not allow 
the exclusion or limitation of incidental or consequential damages, so one or both of these limitation 
may not apply to you.

Legal Rights

: This warranty gives you specific legal rights, and you may also have other rights which 

vary from state to state.

Содержание 4026600

Страница 1: ...er drying times using the Solution by utilizing cold outside air The Solution improves the grain depression of the dehumidified air This increases the vapor pressure differential the key to evaporatio...

Страница 2: ...00 HT that it is mounted on The Phoenix Solution is designed to engage the spring clips found on the Phoenix 200 MAX and 200 HT dehumidifiers An additional bracket with engaging tabs 1 included must b...

Страница 3: ...ations where the temperature of the secondary air stream is significantly below the dew point of the primary air stream condensation may occur inside the Solution s heat exchanger A drip pan underneat...

Страница 4: ...midifier The thermostat is set to turn the impeller on when the process air temperature increases to 80 F The thermostat will turn the impeller off when the process air cools to 70 F Alternatively the...

Страница 5: ...5 www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 7 Wiring Diagram...

Страница 6: ...moval The Solution is a specially designed intercooling head that provides pre cooling to the dehumidifier s incoming air stream Just like the pre cooling feature is the key to the performance leap of...

Страница 7: ...Clamp 1 1979212 7 8 Mounting Screw 1 1027265 8 2 to 1 Terminal Adapter 1 4026414 9 Tubular Handle 1 4026399 Item Description Qty Part Number 10 Feet 4 4024073 11 Duct Wire 1 4024078 12 Blower Screen...

Страница 8: ...8 www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 This page intentionally left blank...

Страница 9: ...stallation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control Limitation and Exclusions If any Phoenix Solution LGR Amplifier part is repaired or replaced the new p...

Отзывы: