4
b)
Technical Data
Rated voltage..
........................................................ :
24 - 29 V DC
Power consumption with rated load
........................ :
max. 4.0 A DC (depending on application)
permissible push force
............................................ :
max. 7000 N (depending on application)
permissible pull force
.............................................. :
max. 4000 N (depending on application)
1)
Operating mode with max. rated load
Intermittent duty
................... :
(AB) 2 min. ON /18 min. OFF
Protection classification
.......................................... :
III
Noise level......
........................................................ :
65 dB(A)
Drive type................................................................ :
Single drive
Type of load...
Push; pull
......................................................... :
2)
Stroke
.................................................................... :
< 500 mm
3)
Adjustment Speed
................................................. :
to 4.7 mm/s (depending on application)
Protection category.
................................................ :
IP20; IPX4
Colours..
grey; black
..................................................................:
Quick release “GQR”.......
....................................... :
to 3000 N (only for push or pull drives)
Cable versions........................................................ :
Cable for permanent mains installation or
cable with attached plug
Dimensions and Weights
Length x width x height of the drive
........................:
min. 190 x 171.5 x 92 mm
min. 236 x 171.5 x 92 mm (with “GQR”)
Weight..
approx
................................................................... :
. 2.5 kg (depending on application)
Ambient conditions for operation, storage and transport
Transport / storage temperature............................. :
from -20 °C to +50 °C
from -4 °F to +122 °F
Operating temperature............................................ :
from +10 °C to +40 °C
from +50 °F to +104 °F
Relative humidity.....................................................:
from 30% to 75%
Air pressure............................................................ :
from 800 hPa to 1060 hPa
Altitude.................................................................... :
< 2000m
1)
Mode of operation: intermittent duty 2 min./18 min. This means that after the unit is operated with ist rated load for
up to two minutes it must then be paused for 18 minutes. The system can malfunction if this pause is not
observed!
2)
Data deviating from these standard values can be established after consultation and depending on the application
and force.
3)
Adjustment speed: the speed at which the clevis can move under no load (the speed varies depending on the
load).
5
Assembly of the MEGAMAT 4 Single Drive
(2)
(1)
(4)
(3)
(6)
(8)
(7)
(9)
(5)
MEGAMAT 4
03/2020
ID 59400 9.0
03/2020
ID 59400 9.0