Phoenix Mecano Dewert Okin DUOMAT 3 CARE EASY Скачать руководство пользователя страница 30

Disposal 

DUOMAT 3 CARE EASY 

30 

78668(-) 

10.  Disposal

10.1  Packaging material 

The packaging material should be sorted into recyclable components and then disposed of in ac-

cordance with the appropriate national environmental regulations (in Germany according to the re-

cycling law KrWG from 01.06.2012; internationally according to the EU Directive 2008/98/EC 

(Waste Framework Directive WFD as of 12.12.2008)). 
 

10.2  Components of the DUOMAT 3 CARE EASY 

The DUOMAT 3 CARE EASY consists of electronic components, cables and metal and plastic 

parts. You should observe all corresponding national and regional environmental regulations when 

disposing of the DUOMAT 3 CARE EASY. 
The disposal of the end product is regulated in Germany by Elektro-G, internationally by the EU Di-

rective 2011/65/EC (RoHS), or by any applicable national laws and regulations. (The end product is 

not regulated by the EU Directive 2002/96/EC (WEEE) and its amendment EU Directive 

2003/108/EC.) 
 

 

The DUOMAT 3 CARE EASY should not be disposed of with normal household waste! 

 

10.3  Batteries 

The disposal of the batteries is regulated in the EU by Battery Directive 2006/66/EC, in Germany 

by the BattG battery law of 25.6.2009, and internationally by any applicable national laws and regu-

lations. 
 

 

These batteries should not be disposed of with normal household waste! 

 
 

Содержание Dewert Okin DUOMAT 3 CARE EASY

Страница 1: ...DUOMAT 3 CARE EASY Installation Instructions Translation of the original installation instructions...

Страница 2: ......

Страница 3: ...e instructions are only intended to be used by the end product manufacturer They should not be given to the operator of the end product The factual information contained within may be used as a basis...

Страница 4: ...T V testing label The construction of the DUOMAT 3 CARE EASY has been inspected by the German Inspection Authority T V The T V also monitors the production of the DUOMAT 3 CARE EASY The official Germa...

Страница 5: ...and Intended Usage 8 2 2 Safety notices within the installation instruction and the operating instructions for the entire machine 9 2 3 Selection and qualification of personnel 9 2 4 Notice on safety...

Страница 6: ...CARE EASY 6 78668 10 Disposal 30 10 1 Packaging material 30 10 2 Components of the DUOMAT 3 CARE EASY 30 10 3 Batteries 30 Declaration of incorporation installation 31 EU Declaration of Conformity 32...

Страница 7: ...duct These installation instructions have been written with due care and attention However we cannot guarantee that the data images and drawings are complete and correct nor do we accept any li abilit...

Страница 8: ...roduct WARNING The DUOMAT 3 CARE EASY may not be used in any environment where combustible or explosive gases or vapours e g anaes thesiology may be present in the proximity of open fires or other hea...

Страница 9: ...n the event of a power outage If the end product manufacturer chooses to guarantee the functionality of the end product during a power outage then the end product manufacturer is responsible for arran...

Страница 10: ...Installation Safety fundamentals during the drive installation and during cable and wire routing refer to the Safety notices to observe during installation section in the Installation chapter Using t...

Страница 11: ...e drive s ratings plate The ratings plate shown is an example the specifications for your drive may differ from this illus tration Figure 2 Ratings plate example DUOMAT 3 2 CARE EASY Model name xxxxx...

Страница 12: ...ected PD14 PD15 power sup ply a DUOMAT 3 CARE EASY as the main drive with a IPROXX2 handset and one or two Mega mat MCZ EASYs as well as a connected PD14 PD15 power supply Systems can be customized by...

Страница 13: ...provement process The Possible Combinations chapter describes the different possible combinations of drives and handsets 4 1 Components The main components of the DUOMAT 3 CARE EASY are the electric m...

Страница 14: ...B Figure 4 Connections located at the rear of the DUOMAT 3 CARE EASY A LSP port for a single drive B Handset port DUOMAT 3 CARE EASY with three connections A B C Figure 5 Connections located at the re...

Страница 15: ...ength x width x height 708 mm x 166 mm x 120 mm Axle gap distance 581 mm Weight Approx 4 4 kg Optional battery operated reset function Voltage Two nine volt batteries type 6LR61 depending on version A...

Страница 16: ...Technical Specifications DUOMAT 3 CARE EASY 16 78668 Figure 6 Dimensions of DUOMAT 3 CARE EASY in mm 708 166 120...

Страница 17: ...ll the drive in the end product so that it is properly aligned This will help pre vent shear stress Do not position the drive at a slanted angle when installing it in the end product A slanted angle b...

Страница 18: ...mple installation Before installing the drive make sure that you are observing all of the safety notices found in the Safety notices to observe during installation section Figure 7 Installing the doub...

Страница 19: ...ress in until the tubes snap into the brackets 5 Close the shutters A on the drive by snapping them back in The DUOMAT 3 CARE EASY is now securely attached to the end product 6 Disconnect all addition...

Страница 20: ...Looping the cable through the strain relief mechanism A Looped in cable B Secured cable C Handset cable loop 1 Connect the plug from the handset to the handset socket on the DUOMAT 3 CARE EASY 2 Loop...

Страница 21: ...ts should be connected or disconnected only when the power sup ply cord connecting cable is unplugged NOTICE There is a delay after the supply voltage is applied before the device actually turns on Wa...

Страница 22: ...the DUOMAT 3 CARE EASY s cable should be plugged into the socket on the PD14 PD15 power supply s cable in order to establish the electrical connection between them Figure 11 Connecting the DUOMAT 3 C...

Страница 23: ...g cable on the PD14 PD15 power supply or disconnect the power to the PD14 PD15 power supply CAUTION Disconnect the batteries if you are using the battery operated reset function Discon nect the nine v...

Страница 24: ...rk together Delayed start up After plugging the PD14 PD15 s power plug into the power outlet NOTICE There is a delay after the supply voltage is applied before the device actually turns on Wait at lea...

Страница 25: ...This power outlet must be accessible at all times during operation so that the cable can be unplugged Or you can disconnect the plug on the DUOMAT 3 CARE EASY from the PD14 PD15 power supply This wil...

Страница 26: ...then be replaced and properly disposed of CAUTION The battery operated reset function is not a safety system and does not avert danger CAUTION Connect the nine volt batteries first when you would lik...

Страница 27: ...e batteries are con nected The drive is suddenly not capable of move ment The overheating protection or system protection has been trig gered Remove the overload change or remove the load Allow the sy...

Страница 28: ...Look over the housing peri odically for any signs of damage Check the housing for breaks or cracks The IP class protection will be impaired by any breakage or cracks At least every six months Look ov...

Страница 29: ...ure cleaner Do not allow fluids to penetrate into the unit Damage to the system could result Do not use a cleanser that contains benzene alcohol or similar solvents 1 Unplug the power cable between th...

Страница 30: ...l corresponding national and regional environmental regulations when disposing of the DUOMAT 3 CARE EASY The disposal of the end product is regulated in Germany by Elektro G internationally by the EU...

Страница 31: ...ne after you have confirmed that the end product into which this machine will be installed complies with the Machinery Directive 2006 42 EC On request the manufacturer is obliged to send the special d...

Страница 32: ...age Directive 2006 95 EC RoHS Directive 2011 65 EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electron...

Страница 33: ...ions EN60601 1 Section 8 Protection against electrical danger leakage currents EN60601 1 Section 11 1 Overheating protection EN60601 1 Section 11 2 Fire prevention EN60601 1 Section 11 3 Design requir...

Страница 34: ...ROXX SE IPROXX or Meditouch EN 60601 2 52 Section 201 9 8 3 2 Static load EN 60601 2 52 Section 201 11 1 1 Temperatures EN 60601 2 52 Section 201 11 6 5 101 Waterproof protection EN 60601 2 52 Section...

Страница 35: ......

Страница 36: ...DewertOkin GmbH Weststra e 1 32278 Kirchlengern Germany Tel 49 0 5223 979 0 Fax 49 0 5223 75182 http www dewertokin de Info dewertokin de ID Nr 78668...

Отзывы: