background image

O

WNER

S

 G

UIDE

U

SE

 

AND

 C

ARE

 M

ANUAL

DUCTED COOLER MODELS:

 

PD4803      PD6803

PH4803      PH6803 

1-999-2

61

4

    Date: 

7

/1

9

Safety

Installation

Start-up

Operation

Maintenance

Trouble Shooting

—

Read all instructions carefully before installation.   

—

Use only the blower motor and circulating pump(s) 
combinations marked on the Model Nameplate indicating 
suitability for use in this model. Any other motors or pumps 
cannot be substituted.

—

Installation work and electrical wiring must be done by 
qualified person(s) in accordance with all applicable codes 
and standards, including fire rated construction.

—

When cutting or drilling into a wall or ceiling, do not 
damage electrical wiring or other concealed utilities (water 
or gas lines, sewer lines, etc.).

—

Cooler motor, pump, cabinet and junction box must be 
grounded in accordance with all local and national codes. 
A ground wire must be used between the power supply 
and the cooler.

—

Be sure that the cooler is connected to proper line voltage 
stamped on the pump and blower (fan) motor specification 
plate. NOTE: Improper voltage will void the pump and/or 
motor warranties and may cause serious personal injury 
or property damage.

—

Do not operate this blower (fan) motor with any solid-state 
speed control device.

—

Always disconnect electrical power to unit before working 
on or servicing cooler. More than one disconnect switch 
may be required to de-energize the equipment for 
servicing.

—

Do not remove access panels while cooler is running, this 
may cause the blower (fan) motor to overload and damage 
the motor windings.

NOTE:

—

Do not locate unit near exhaust or vent pipes as odors or 
fumes may be drawn into cooler.

—

Use of anode devices, chemical additives or treatments in this 
cooler will void the warranty.

—

Your warranty does not cover shipping damage. Report all 
shipping damage at once to dealer or carrier making the 
delivery.

—

For future reference, record the model and serial numbers, 
date and place of purchase of your evaporative cooler here:

Model #   

Serial #

Date of Purchase:

Place of Purchase:

Congratulations: You have purchased a product of superior performance and design, which will give the best service when properly installed, operated 
and maintained. 

This guide will provide you with information needed to mount, operate, inspect, maintain, and troubleshoot your evaporative air cooler.

The first section, Installation and Start-Up, gives details for installation. The second section, Maintenance, contains operational and maintenance 
instructions , while Troubleshooting includes information on commonly encountered problems.

INSTALLER: Please deliver this guide to owner.

READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS.

WARNING -

TO REDUCE THE RISK OF FIRE, ELECTRIC

 

SHOCK,

 OR INJURY TO PERSONS, OBSERVE THE FOLLOWING.

!

Содержание Aerocool Pro Series

Страница 1: ...to unit before working on or servicing cooler More than one disconnect switch may be required to de energize the equipment for servicing Do not remove access panels while cooler is running this may ca...

Страница 2: ...roduced by the cooler You can adjust different windows in the house to direct the most airflow to the areas that are occupied during different times of the day or night example living room windows dur...

Страница 3: ...ligned vertically 3 Insert the power supply wires from circuit board thru chase nipple into switch box Connect Power Supply CAUTION The external power supply to the unit must be adequately grounded an...

Страница 4: ...city and motor amperage may decrease due to the increased duct resistance The adjustable motor pulley is to be used ONLY to return the cooler motor to it s maximum allowable amperage and should not be...

Страница 5: ...uality etc For maximum cooling efficiency long life and appearance every two months during operation the cooler should be inspected and cleaned NOTE Do Not Undercoat the Water Reservoir The parts of y...

Страница 6: ...ore attempting to install open or service your cooler If the cooler is thermostatically controlled the thermostat is not to be used as the power supply disconnect as it may reset and start the unit un...

Страница 7: ...cci n de Instalaci n e Inicio es especialmente para el instalador La secci n segunda Mantenimiento contiene instrucciones de operaci n y mantenimiento paraelpropietario mientrasquelasecci ndeDetecci n...

Страница 8: ...vapores pueden ser inducidos por la unidad NOTA Cuando los enfriadores son instalados dentro de la jurisdicci n de los c digos de edificaci n de la Ciudad de Los ngeles solamente pueden ser instalados...

Страница 9: ...ra montar la caja del interruptor al enfriador Monte la caja del interruptor como sigue 3 Inserte los alambres de la fuente de poder de la tableta de circuito atrav s del niple hacia la caja del inter...

Страница 10: ...agua filtros gabinete etc P Filtros del enfriador se mojen parejos no reas secas P El ajuste del nivel del agua sea correcto P Verifique el flujo de agua completo P Turbina motor giran libremente no r...

Страница 11: ...s enfriador El enfriador debe recibir servicio completo a menos una vez por a o y m s seguido si las condiciones lo requieren ambiente polvo uso constante calidad del agua etc Para m xima eficiencia d...

Страница 12: ...brado no funciona Agua hacia el enfriador cerrada Corriente el ctrica desconectada Banda muy floja o apretada Motor no funciona Control termostato no funciona Banda rota Baja voltaje Banda demasiado a...

Отзывы: